background image

Savant Low Voltage Keypad Deployment Guide

12     of     22

Copyright © 2019 Savant Systems, LLC

009-1731-00  |  190401

3.2. SKL-3040

Connecting Power

 ELECTRIC SHOCK!

 The 120/240V AC source power poses an 

electrical shock hazard that has the potential to cause serious injury 

to installers and end users.

 

IMPORTANT!

 

A licensed electrician is required to make AC electrical 

connections to the keypad modules. Isolate and turn off power 

at the main breaker panel prior to installing any electrical 

devices.

 

For supply, neutral, and ground connections, use only #14 AWG 

or larger solid copper wire.

Prepping Enclosure

Refer to the diagram just below these instruction for reference
1.  Remove power at the circuit breaker.
2.  Remove the lid from enclosure if one is installed.
3.  Turn the captive screw on the AC compartment panel 

counterclockwise (CCW) until the screw pops up.

4.  Slide the cover up and out away from the enclosure. Put aside.
5.  Remove the two WAGO 6 position push connectors that were 

shipped in the AC compartment and set aside.

6.  Remove one of the electrical knockouts at the bottom of the 

enclosure and install a 1/2 inch electrical cable clamp.

7.  Remove electrical knockout from module slot 1 and install 

1/2 inch nylon insulating bushing.  If installing more than one 

module, repeat for slots 2 and 3 as needed.

 

Module 

Slot 1

Slide up and

then out

 

Module 

Slot 2

 

Module 

Slot 3

4

3

6

7

Keypad Module Installation

1.  Remove the keypad module(s) and corresponding 120/240V AC cable(s) 

from shipping box.

2.  Flip keypad module over so the power supply is accessible.
3.  Plug the keypad module PS to 120/240V AC cable into the 2 pin connector 

located on the bottom edge of the power supply board. The connector is 

keyed to aid installation. See diagram below:

Keypad Module Power Supply

Neutral (White)

Hot (Black)

Green (Gnd)

4.  Position keypad module over the knockout removed during step 7 of 

Prepping Enclosure

.

5.  Insert the wires through the insulated bushing installed during step 7 of 

Prepping Enclosure

.

6.  Slide the tabs on the bottom of the keypad module into the slots to the left 

and right of the electrical knockout hole.

7.  To hold the module in place before it is secured. Depress the top flange so 

the tab on the module seats behind the hook on the enclosure.

8.  To secure keypad module to enclosure, turn the captive screw on top of 

module clockwise (CW).

9.  Repeat steps 1 - 8 to install any additional keypad modules in slots 2 and 3 

of enclosure. 

Summary of Contents for PWM-ENC3

Page 1: ...yright 2019 Savant System LLC Savant com 508 683 2500 Savant Low Voltage Keypads PWM ENC3 SKL 3040 SKL 1010 WPB xxLV06 WPK xxLV05 WPB xxLV02 Deployment Guide Document Number 009 1731 00 Document Date March 2019 Document Supports da Vinci 9 0 ...

Page 2: ...LV02 8 2 5 WPK xxLV05 9 2 6 WPB xxLV06 10 3 Installation 11 3 1 PWM ENC3 11 3 2 SKL 3040 12 3 3 Keypads 14 3 4 Changing Buttons 14 4 Wiring Keypads 15 4 1 Wiring Example with Two Keypads 15 4 2 Wiring Contact Closure Control 16 5 Blueprint 17 5 1 Adding Keypads to Configuration 17 5 2 Configuring a Keypad 17 5 3 Programming a Button 18 5 4 Binding Keypads 19 Appendix Keypad Binding Indicator Infor...

Page 3: ...y such attachments accessories 12 Disconnect any outlet powered apparatus from its power source during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as a damaged power supply cord or plug liquid being spilled or objects having fallen into the apparatus the appa...

Page 4: ...r s w enclosure if required SKL 3040 or SKL 1010 Savant Host licensed and running da Vinci 9 0 or higher Savant Development Environment SDE MacBook Running da Vinci 9 0 or higher Lighting or other devices to be controlled by the keypads Deployment Steps Follow these steps to successfully deploy Savant Low Voltage Keypads This page can be used as a checklist to record which steps have been complete...

Page 5: ... 3 5 in 8 89 cm 14 55 lbs 6 60 kg Enclosure with Cover 19 in 48 26 cm 15 25 in 38 74 cm 4 72 in 11 99 cm 15 85 lbs 7 08 kg Shipping 21 0 in 53 34 cm 17 0 in 43 18 cm 5 0 in 12 7 cm 16 lbs 7 26 kg Front View C B D A A The PWM ENC3 enclosure supports up to three SKL 3040 40 Keypad Power and Control Modules The Keypad Modules are not included with the enclosure and need to be purchased separately B T...

Page 6: ...ded Regulatory RoHS Compliant Minimum Supported Release Savant OS da Vinci 9 0 Main Power Keypad Bus 1 Keypad Bus 2 Keypad Bus 3 Ethernet Keypad Bus 4 Keypad Bus 5 Reset Status A C D E B A Keypad Bus 1 5 The 40 Keypad Power and Control Module supports up to 10 low voltage keypads per bus wired in series daisy chained with a total of up to 40 keypads per module Keypad Bus Status LED Green normal Am...

Page 7: ...while powered on to clear network settings Status LED will rapidly blink red when reset is complete B Ethernet Connect to network via CAT5 5E 6 C Bus In Reserved for future use D Bus Out Reserved for future use E Status LED No Network Connection 5 second blink 1 5 second off No Host Connection 2 rapid blinks Host Connected On solid green Firmware Upgrade in Progress long blink with short off F Key...

Page 8: ...ront View Rear View A B C D A Ambient Light Sensor Detects the level of ambient light in the room and adjusts the LED brightness on the front panel The ambient light sensor operation is modified using RacePoint Blueprint B Dimming Level Six indicator LEDs track the brightness of the load LEDs turn on from left to right as intensity on load increases and turns off from right to left as intensity de...

Page 9: ...ear View A Ambient Light Sensor Detects the level of ambient light in the room and adjusts the LED brightness on the front panel The ambient light sensor operation is modified using RacePoint Blueprint B Reset Button The reset button has two functions Press and release the reset button will reboot the keypad Press and hold the reset button for five seconds will Factory reset the keypad This will e...

Page 10: ... Max Power 1 4 Watts Front View Rear View A Ambient Light Sensor Detects the level of ambient light in the room and adjusts the LED brightness on the front panel The ambient light sensor operation is modified using RacePoint Blueprint B Dimming Level Six indicator LEDs track the brightness of the load LEDs turn on from left to right as intensity on load increases and turns off from right to left a...

Page 11: ... the panel is being mounted to is drywall with no solid surface behind it sturdy wall anchors that can hold a minimum of 50 lbs 22 7 kg is sufficient 5 Screw the panel to the wall and ensure it is securely mounted 8 x 1 1 4 inch In Wall Mount Instructions 1 Loosen the four hold down screws that secure the lid to the enclosure 2 Push up on the lid and pull away from the enclosure Set lid aside 3 Lo...

Page 12: ... electrical cable clamp 7 Remove electrical knockout from module slot 1 and install 1 2 inch nylon insulating bushing If installing more than one module repeat for slots 2 and 3 as needed Module Slot 1 Slide up and then out Module Slot 2 Module Slot 3 4 3 6 7 Keypad Module Installation 1 Remove the keypad module s and corresponding 120 240V AC cable s from shipping box 2 Flip keypad module over so...

Page 13: ... Prepping Enclosure section Tighten clamp 3 Using the 6 position WAGO connector mounted to the green ground wire screwed to the enclosure connect all ground wires together 4 Using one of the WAGO 6 position push connectors included with the enclosure connect all the neutral wires together 5 Using one of the WAGO 6 position push connectors supplied with the enclosure connect all the hot wires toget...

Page 14: ... Buttons This section affects the Echo Configurable Keypads and Echo Dial keypads The buttons have two hinge points for capture at the base This hinge point allows for the button press feel The same removal and installation process can between used across the single and double buttons Button Removal 1 Using a flathead screw driver apply light pressure outward on one of the hinge points Place the s...

Page 15: ...Black To keypad pin 2 ground A White To keypad pin 3 B Orange To keypad pin 4 B A Keypad Red 24V DC input Black Power return White Data A on Keypad Link Orange Data B on Keypad Link Yellow Contact Closure Control 4 1 Wiring Example with Two Keypads This example show keypads wired in a daisy chain This is the only supported method of wiring keypads on a keypad bus Keypad Bus 1 Keypad Bus 2 Keypad B...

Page 16: ...Wiring Contact Closure Control This diagram shows how to wire a contact closure device to a Echo Low Voltage keypad the control of what this does is programmed in Blueprint like a keypad button Contact Closure Output To Keypad Link Occupancy Sensor NOTE Contact Closure wire colors do not represent any standard ...

Page 17: ... Button Keypad ECHO Wired Dounle Single Large Buttons Keypad Metropolitan Wireless Dimmer Metropolitan Wireless Fan Controller Metropolitan Wireless Keypad with Dial 3 4 4 Click Add 5 2 Configuring a Keypad This section only covers the basic properties of a keypad for more information about keypad programming see the Savant Lighting and Keypad Programming Guide on the Savant Customer Community Fro...

Page 18: ...ration with keypads added and Lighting Manager open do the following 1 Select a keypad 2 Select a button Lights On Button 2 Down Up Closure On Closure Off Lighting Control Properties for Button Lights On Property Value LED Behavior Address Button Label Scene Function Savant Scene LED Color Any On Not All Off Lights On MB ceiling cans On 0 White 2 3 4 5 6 7 3 Select LED Color as desired 4 Enter the...

Page 19: ...hts Address 002 Discover Hide bound devices Configured Devices 3 Echo Wired Low Voltage Keypads 0 discovered of 3 2 3 3 Click Discover 4 Find the Low Voltage Keypad Controller SKL or Keypad Link that is going to have keypads bound Click the disclosure triangle to show the keypad links Show bound devices Devices 7 Discovered Low Voltage Keypad Controllers 001AAE0000000086 10 0 100 164 1 0 108 3 UID...

Page 20: ...dress 003 Show bound devices Devices 7 Discovered Low Voltage Keypad Controllers 001AAE0000000086 10 0 100 164 1 0 108 3 UID IP Firmware Keypads Address 0326 Keypad Address 0421 Keypad Address 043D Keypad Connect Scan Low Voltage Keypad Controllers 1 Echo Wireless Keypads 6 DMX Controllers 1 PBC Controllers 1 Lighting Keypad Manager for Dersd Keypads and Controllers Stop Discover Hide bound device...

Page 21: ...e Keypad Controllers 1 Echo Wireless Keypads 6 DMX Controllers 1 PBC Controllers 1 Stop Discover Hide bound devices Configured Devices 3 Echo Wired Low Voltage Keypads 0 discovered of 3 Bound LED icon Appendix Keypad Binding Indicator Information This appendix gives information on Lighting Manager Binding LED icon A keypad that is bound means that the UID of the keypad and the keypad link have bee...

Page 22: ...rights reserved Savant Savant App TrueImage Savant Host Now You Can RacePoint Blueprint Single App Home TrueCommand TrueControl and the Savant logo are trademarks of Savant Systems LLC AirPlay Apple AirPort Express AirPort Extreme Apple TV Apple Remote Desktop FireWire iMac iTunes iPad iPad mini iPad Air iPhone MacBook Mac and OS X are trademarks or trade names of Apple Inc iOS is a trademark of C...