Savant Low Voltage Keypad Deployment Guide
12 of 22
Copyright © 2019 Savant Systems, LLC
009-1731-00 | 190401
3.2. SKL-3040
Connecting Power
ELECTRIC SHOCK!
The 120/240V AC source power poses an
electrical shock hazard that has the potential to cause serious injury
to installers and end users.
IMPORTANT!
–
A licensed electrician is required to make AC electrical
connections to the keypad modules. Isolate and turn off power
at the main breaker panel prior to installing any electrical
devices.
–
For supply, neutral, and ground connections, use only #14 AWG
or larger solid copper wire.
Prepping Enclosure
Refer to the diagram just below these instruction for reference
1. Remove power at the circuit breaker.
2. Remove the lid from enclosure if one is installed.
3. Turn the captive screw on the AC compartment panel
counterclockwise (CCW) until the screw pops up.
4. Slide the cover up and out away from the enclosure. Put aside.
5. Remove the two WAGO 6 position push connectors that were
shipped in the AC compartment and set aside.
6. Remove one of the electrical knockouts at the bottom of the
enclosure and install a 1/2 inch electrical cable clamp.
7. Remove electrical knockout from module slot 1 and install
1/2 inch nylon insulating bushing. If installing more than one
module, repeat for slots 2 and 3 as needed.
Module
Slot 1
Slide up and
then out
Module
Slot 2
Module
Slot 3
4
3
6
7
Keypad Module Installation
1. Remove the keypad module(s) and corresponding 120/240V AC cable(s)
from shipping box.
2. Flip keypad module over so the power supply is accessible.
3. Plug the keypad module PS to 120/240V AC cable into the 2 pin connector
located on the bottom edge of the power supply board. The connector is
keyed to aid installation. See diagram below:
Keypad Module Power Supply
Neutral (White)
Hot (Black)
Green (Gnd)
4. Position keypad module over the knockout removed during step 7 of
.
5. Insert the wires through the insulated bushing installed during step 7 of
.
6. Slide the tabs on the bottom of the keypad module into the slots to the left
and right of the electrical knockout hole.
7. To hold the module in place before it is secured. Depress the top flange so
the tab on the module seats behind the hook on the enclosure.
8. To secure keypad module to enclosure, turn the captive screw on top of
module clockwise (CW).
9. Repeat steps 1 - 8 to install any additional keypad modules in slots 2 and 3