background image

Copyright © 2018 Savant Systems, LLC

Wired DMX and 0-10V Lighting Controller Deployment Guide
009-1747-00  |  181116

3     of     29

Important Safety Information - Read First

Before installing, configuring, or operating any equipment and other, 

Savant recommends that each dealer, integrator, installer, etc. access 

and read all the relevant technical documentation. Savant technical 

documentation can be located by visiting 

Savant.com

. Vendor 

documentation is supplied with the equipment.

Read and understand all safety instructions, cautions, and warnings in 

this document and the labels on the equipment.

Safety Classifications In this Document

NOTE

:

Provides special information for installing, configuring, 

and operating the equipment.

 

IMPORTANT!

Provides special information that is critical to installing, 

configuring, and operating the equipment.

 

CAUTION!

Provides special information for avoiding situations that 

may cause damage to equipment.

 

WARNING!

Provides special information for avoiding situations that 

may cause physical danger to the installer, end user, etc.

Electric Shock Prevention

 ELECTRIC SHOCK!

 The source power poses an electric shock hazard 

that has the potential to cause serious injury to installers and end 

users.

 ELECTRICAL DISCONNECT

: The source power outlet and power 

supply input power sockets should be easily accessible to 

disconnect power in the event of an electrical hazard or 

malfunction.

Weight Injury Prevention

 WEIGHT INJURY!

 Installing some of the Savant equipment requires 

two installers to ensure safe handling during installation. Failure to 

use two installers may result in injury.

Safety Statements

All safety instructions below should be read, understood, and applied 

under all relevant circumstances when working with this equipment.
1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat.

9.  Do not defeat the safety purpose of any polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. 

A grounding type plug has two blades and a third grounding prong. 

The wide blade or the third prong is provided for your safety. If any 

provided plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10.  Protect any power cord from being walked on or pinched; particularly 

at plugs, convenience receptacles, and the point where they exit from 

the apparatus.

11.  Only use attachments/accessories specified by the manufacturer, 

following all relevant safety precautions for any such attachments/

accessories.

12.  Disconnect any outlet powered apparatus from its power source 

during lightning storms or when unused for long periods of time.

13.  Refer all servicing to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as a 

damaged power supply cord or plug, liquid being spilled or objects 

having fallen into the apparatus, the apparatus has been exposed to 

rain or moisture, apparatus having been dropped, or other failure to 

operate normally.

14.  To completely disconnect this equipment from the AC mains, 

disconnect the power supply cord plug from the AC receptacle.

15.  For applicable equipment, use the included power cord with the 

grounding prong intact to ensure proper grounding of the device.

16.  For any hardwired or fixed in-wall apparatus, carefully follow all wiring 

diagrams and instructions. All electrical wiring and servicing should 

be performed by a properly licensed electrician.

Summary of Contents for LCB-010V8

Page 1: ...annis MA 02601 Savant com 508 683 2500 Document Number 009 1747 00 Document Date November 2018 Document Supports da Vinci 8 9 Wired DMX Low Voltage Lighting Controller LCB DMX1 Wired 0 10V Control 8 C...

Page 2: ...onfiguration Add Controller 12 5 1 Add Controller to the Lighting Manager 12 5 2 Obtain UID of Controller 13 5 3 Add UID to Lighting Manager 13 5 4 Scan for Controller 14 5 5 Access OLA Server Web UI...

Page 3: ...these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with t...

Page 4: ...twork meeting Savant requirements See Appendix B Network Requirements 6 Lighting fixture s that support either DMX or 0 10V Lighting The type of lighting fixture installed is dependent on the controll...

Page 5: ...en the 5V DC port and a surge protected 120 240V AC 50 60 Hz outlet B Ethernet 8 Pin RJ 45 port 10 100 1000 BaseT auto negotiating port with link activity LEDs C Link LED Solid Orange Network Speed 10...

Page 6: ...0 cm 7 lb 0 32 kg Shipping 8 8 in 22 35 cm 7 80 in 19 81 cm 1 6 in 4 06 cm 1 3 lb 0 59 kg Rack Space 1U Regulatory Safety and Emissions FCC Part 15 CE Mark C Tick RohS Compliant Right Panel Left Pane...

Page 7: ...Connection No Connection Local Lan Additional Information Connect Ethernet port to the local network using Cat 5e 6 7 cable Savant recommends using DHCP reservation to assign the IP Address Fixtures...

Page 8: ...d Colors are used in diagram to distinquish individual wires Each port supports daisy chaining up to 8 lighting fixtures 1 Int Tuneable White Standard White Color Int Color Int Color Int Color 1 2 3 4...

Page 9: ...put is supported See the USAI Lighting Products Specification Sheets located on the Savant Customer Community for information regarding the individual lighting fix tures 5V DC 0 10V Lighting Controlle...

Page 10: ...e 6 7 LED Strip To 120 240VAC DMX Port Pinout Pin 1 Pin 2 Pin 3 Pin 4 Ground Pin 5 Data Pin 6 Data Pin 7 Pin 8 RJ 45 Connector Gold pins facing up Pin 1 Pin 8 No Connection No Connection No Connection...

Page 11: ...X Port Pinout Pin 1 Pin 2 Pin 3 Pin 4 Ground Pin 5 Data Pin 6 Data Pin 7 Pin 8 RJ 45 Connector Gold pins facing up Pin 1 Pin 8 No Connection No Connection No Connection No Connection No Connection LED...

Page 12: ...Add button and verify the DMX Controller is added to the Devices Controllers tab 6 Optional If desired the name of the controller can be changed To do this double click the name and enter a new name...

Page 13: ...ocation Address 985DADD167BE0070 Control Lighting Keypad Manager for Smith Residence Smith Residence DMX Controller 1 Keypads Lighting Devices Controllers Family Room DMX Controller 1 UID 1 2 3 Embedd...

Page 14: ...dence Devices Controllers BLE DMX 010V Scan Connect Opens DMX OLA Server Web UI 4 5 5 4 Scan for Controller With the UID set the lighting manager can locate the controller in the network 1 Select the...

Page 15: ...niverse supports all Savant wired lighting controllers 3 Select the Settings tab 4 Optional If desired the Universe Name field can be changed To modify double click this field and rename to something...

Page 16: ...ing this addressing scheme However if required the starting address can be entered here and the rest of the addressing for that lighting fixture will be automatically populated Addressing of the light...

Page 17: ...right panel all fields associated with this driver will populate In the rightmost panel configure each of the fields described below Select Save to apply each change made DMX Personality Select which...

Page 18: ...g Fixture 1 is assigned addresses 1 2 3 and 4 C The bottom row gives an indication of how the table is utilized Free Slots first 13 Indicates that the first free address in the table is cell 13 last 5...

Page 19: ...to the right of the sliders Intensity range 0 255 C Each slider represents a color space to a specific lighting fixture The lighting fixture installed determines what color space s are adjusted In th...

Page 20: ...nager The fixture should power On and Off as button is pressed 9 Select Disconnect button to disconnect from that fixture 10 Continue to Connect to remaining fixtures and verify they can also be switc...

Page 21: ...Location Kitchen Savant Smart Group Savant Smart Group Type UID Address Sync Loads Lighting Scenes Keypads Lighting Keypad Manager for Smith Residence Devices Controllers BLE DMX 010V Scan On Off Bli...

Page 22: ...on from the Blueprint tool bar See image below Select Upload to Master 4 In the configuration must be saved dialog box that opens read the dialog and select Save and Upload 5 The System Monitor applic...

Page 23: ...181116 23 of 29 10 Savant Pro App With the upload complete the DMX lighting network will either create a Lighting Service in the Savant Pro 8 App or get added to an existing Lighting Service See the...

Page 24: ...identifies the Universe Merge Mode Set to LTP latest takes precedent and is the recommended setting Output Ports ArtNet 127 0 0 is the data distribution protocol supported Home Universes Savant Light...

Page 25: ...ting Universe for a DMX or 0 10V lighting controller Home Universes Savant Lighting Plugins Settings RDM RDM Patcher DMX Monitor DMX Console DMX Personality Identify Device Manufacturers Label Reset D...

Page 26: ...ill cause the output of the lighting fixture to look linear when moving the slider on the dimmer from low to high intensity Dimmer Minimum Minimum Level Increasing When increasing power at the output...

Page 27: ...Save The lighting fixture will begin flashing once per second Uncheck the same box and select Save to stop the flashing Manufacturers Label The manufacturer of the driver installed in the lighting fix...

Page 28: ...recommends using DHCP reservation within the router By using this method static IP Addresses for all devices can be managed from a single UI avoiding the need to access devices individually Setting D...

Page 29: ...C All rights reserved Savant Savant App TrueImage Savant Host Now You Can RacePoint Blueprint Single App Home TrueCommand TrueControl and the Savant logo are trademarks of Savant Systems LLC AirPlay A...

Reviews: