![Savant CLI-W210 Deployment Manual Download Page 6](http://html.mh-extra.com/html/savant/cli-w210/cli-w210_deployment-manual_1203683006.webp)
Multistat Smart Thermostat Deployment Guide (CLI-W210x/W200x)
6 of 21
45 Perseverance Way, Hyannis MA 02601
009-1959-00 | 200723
| 508.683.2500
4. Wiring Diagrams
Use the diagrams below when wiring the various types of HVAC systems.
1 Stage Heat
o
G
AUX OUT
AUX
IN
RS2
RS1
GND
GND
R
X-
RX+
GND
1-
WIRE
5V
DC
Y2
Y1
W2
W1
RC
RH
TX+
TX- 24C
120V AC
C
R
W1
24V AC
FURNACE CONNECTIONS
Fan Relay
G
1st Stage
Heat
–
Connect 24V AC to the RC and 24C terminals.
–
Leave jumper shunt JP1 on the electronics board installed.
–
Connect W1 from the thermostat to W1 (stage 1 heat) in the HVAC
system.
–
Connect G from the thermostat to the fan terminal in the HVAC
system.
–
Savant recommends using standard #18 AWG HVAC wiring.
1 Stage Heat, 1 Stage Cool
o
G
AUX
OUT
AUX
IN
RS2
RS1
GND
GND
R
X-
RX+
GND
1-
WIRE
5V
DC
Y2
Y1
W2
W1
RC
RH
TX+
TX- 24C
C
W1
1st Stage
Heat
24V AC
120V AC
FURNACE CONNECTIONS
AIR CONDITIONER
CONNECTIONS
Compressor
1st Stage
Fan Relay
R
G
Y1
C
–
Connect 24V AC to the RC and 24C terminals.
–
Leave jumper shunt JP1 on the electronics board installed.
–
Connect W1 from the thermostat to W1 (stage 1 heating) in the HVAC
system.
–
Connect Y1 from the thermostat to Y1 (stage 1 cooling) in the HVAC
system.
–
Connect G from the thermostat to the fan terminal in the HVAC
system.
–
Savant recommends using standard #18 AWG HVAC wiring.