background image

SAVANNAH STOKER v3 INSTRUCTION MANUAL 

2015.01 Copyright © Sound Solutions, LLC.  All Rights Reserved.  Find us on Facebook.com/SavannahStoker , Pelletheads.com and LetsTalkBBQ.com                                                              

4

                  

4. Basic Operations 

 

4.1

 

Turning the Controller On/Off 

 

To turn the Controller ON:

  

Connect  the  smoker  to  a  GFCI  protected  AC  outlet.  The  Stand-by 
indicator will illuminate RED indicating power is present at the controller.   
Press  the  Power  KEY

.  The  Stand-by  indicator  will  go  OFF.  Both 

displays  on  the  controller  will  flash.  The  top  display  (PV)  will  show  the 
current  temperature  inside  the  cooking  chamber.  The  bottom  display 
(SV) is the desired cooking temperature.  
 

To turn the Controller OFF: 

Press the POWER KEY

, the controller will start the “COOL DOWN’ 

cycle. The top display will flash “HOT” and the fan light will blink until the 
cooking chamber temperature drops below 120° (the value of Fant). The 
controller  will  power-off  and  the  Stand-by  indicator  will  illuminate  RED 
indicating power is present at the controller. 

 

4.2

 

Changing the Cooking Temperature, the Setpoint Value (SV) 

 

Recommended start-up temperature is 225° to preheat the grill, but any 
start-up  temperature  can  be  set  between  160°  -  550°F  in  one  (1°) 
degree increments. To change the Setpoint Value (SV) press/release the 
▼ or ▲ KEY. The decimal point on the lower right corner of the display 
will start to flash. Press the ▼ or ▲ KEY to change SV until the desired 
temperature  is  displayed.  The  decimal  point  will  stop  flashing  after  no 
KEY is pressed for 3 seconds. You can press the 

A/M KEY

 to move the 

flashing  decimal  point  to  the  desired  digit  that  needs  to  change.  Then 
press the ▼ or ▲ KEY to change SV starting from that digit. 

 

4.3

 

Display Modes:  

The controller has 

3 Display Modes

.  

 

Display Mode 1.

  

When the controller first turns ON it will be in 

Display Mode 1.

  This is 

the  most  used  Display  Mode.  The  (PV)  display  shows  the  temperature 
inside  to  cooking  chamber.  The  (SV)  display  shows  the  target 
temperature of the cooking chamber.  

 

Display Mode 2.

  

It you want to watch the controller in action place the controller in Display 
Mode 2. When in Display Mode 1, press/release the 

SET KEY

 to enter 

Display  Mode  2

.  The  (PV)  display  shows  the  temperature  inside  the 

cooking chamber. The (SV) display changes to show the auger’s output 
as a  % of the cycle time (t).  Example: If the (SV) display  is  “A 60”, the 
“60” indicates the Auger is running 60% of the cycle time. This value may 
change  at  the  start  of  each  cycle.  The  “A”  in  the  display  indicates  the 
controller is in the “Automatic Control Mode”.  
Pressing  the 

A/M  KEY

  will  switch  the  controller  to  “Manual  Control 

Mode”.  When  in  Manual  Control  Mode,  the  first  digit  to  the  left  will 
change to an “M” to indicate Manual Control Mode. Refer to the Section 
5.1 Control Modes on the use of “Manual Control Mode”   

 

Display Mode 3.

  

When  in 

Display  Mode  1

,  press/hold  the 

SET  KEY

  for  2  seconds  to 

enter 

Display  Mode  3. 

Display  Mode  3  is  where  the  values  of  the 

various  operation  parameters  can  be  manually  changed.  The  (PV) 
display shows the parameter name, the (SV) display is the current value. 
Use ▲ and ▼ to modify the current value. Press/release the SET KEY 
to advance to the next parameter. After the last parameter is displayed, 
press/release the SET KEY to exit Display Mode 3. 

 
 
 
 
 

4.4

 

Using the Auger Bypass Feature. 

 

Press/release  the 

AUG  KEY

  to  run  the  Auger  continuously  bypassing 

the  Control  Modes.  The  (SV)  display  will  flash  “ACC”  and  the  last  set 
temperature  when  the  Auger  Bypass  feature  is  being  used. 
Press/release  again  to  return  to  normal  operation.    The  Auger  Bypass 
feature  is  typically  used  for  high  temp  grilling  or  to  raise  the  grill’s 
temperature more quickly than Automatic Mode.  
 

 Caution: When using Auger Bypass Mode the cooking 

chamber,  drip  tray,  and  the  grease  drain  system 
should  be  clean.  Cooking  at  high  temperatures 
increases the risk of having a grease fire. Never leave 
the grill unattended. Always return the auger to normal 
operation before turning off the grill.  

 

4.5

 

Changing the Fan Speed 

 

Place the controller in Display Mode 3. 
Press/release the SET key to page to parameter 

FanS

.  

Use the ▲ and ▼keys to modify the current value.  
3 is normal fan speed, 2 is medium fan speed and 1 is slow fan speed.  
Medium Fan Speed is great to use when smoking below 225° or when 
using  the  STOKER  below  250°.  Limit  the  use  of  the  low  fan  speed  for 
cold smokin’.On low fan speed the risk of losing fire is greatly increased. 

Note: Always return the Fan Speed to normal for cool down. 

  
 
This space is provided for your notes:   
  
__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________ 

Summary of Contents for STOKER v3

Page 1: ...40VAC 3A Igniter Output Zero crossing SSR 100 240VAC 10A Power supply 100 240VAC 50 60Hz Power consumption 300 Watts at startup 60 Watts normal operation Ambient temperature 0 50 C 32 122 F Fuse 5x20m...

Page 2: ...oller to the pellet hopper saving the screws for use later 2 Gently pull the controller away from the hopper while sliding it slightly to the right Rotate the left side toward you so the circuit board...

Page 3: ...point will stop flashing after no KEY is pressed for 3 seconds You can press the A M KEY to move the flashing decimal point to the desired digit that needs to change Then press the or KEY to change SV...

Page 4: ...ller is in the Automatic Control Mode Pressing the A M KEY will switch the controller to Manual Control Mode When in Manual Control Mode the first digit to the left will change to an M to indicate Man...

Page 5: ...Ys will lower or raise the auger runtime Note Manual mode will be running the last output value when the controller was in Automatic Mode The runtime cannot be set lower than the OutL parameter value...

Page 6: ...acteristics of your barbecue Chart and save your cook data Set alarms on your computer Ramp temperatures up down by time or food temperature and more The author posts on the Virtual Weber Bulletin Boa...

Page 7: ...note the controller uses an enhanced version of PID control algorithms Tuning of the controller is different than traditional PID controllers The parameters are explained below Before adjusting any o...

Page 8: ...second cycle time or 3 4 seconds OutH is the maximum of the cycle time the auger will run Default is 100 The high limit is used to help reduce temperature overshoots that will occur at start up after...

Reviews: