SAVANNAH STOKER v3 INSTRUCTION MANUAL
2015.01 Copyright © Sound Solutions, LLC. All Rights Reserved. Find us on Facebook.com/SavannahStoker , Pelletheads.com and LetsTalkBBQ.com
4
4. Basic Operations
4.1
Turning the Controller On/Off
To turn the Controller ON:
Connect the smoker to a GFCI protected AC outlet. The Stand-by
indicator will illuminate RED indicating power is present at the controller.
Press the Power KEY
. The Stand-by indicator will go OFF. Both
displays on the controller will flash. The top display (PV) will show the
current temperature inside the cooking chamber. The bottom display
(SV) is the desired cooking temperature.
To turn the Controller OFF:
Press the POWER KEY
, the controller will start the “COOL DOWN’
cycle. The top display will flash “HOT” and the fan light will blink until the
cooking chamber temperature drops below 120° (the value of Fant). The
controller will power-off and the Stand-by indicator will illuminate RED
indicating power is present at the controller.
4.2
Changing the Cooking Temperature, the Setpoint Value (SV)
Recommended start-up temperature is 225° to preheat the grill, but any
start-up temperature can be set between 160° - 550°F in one (1°)
degree increments. To change the Setpoint Value (SV) press/release the
▼ or ▲ KEY. The decimal point on the lower right corner of the display
will start to flash. Press the ▼ or ▲ KEY to change SV until the desired
temperature is displayed. The decimal point will stop flashing after no
KEY is pressed for 3 seconds. You can press the
A/M KEY
to move the
flashing decimal point to the desired digit that needs to change. Then
press the ▼ or ▲ KEY to change SV starting from that digit.
4.3
Display Modes:
The controller has
3 Display Modes
.
Display Mode 1.
When the controller first turns ON it will be in
Display Mode 1.
This is
the most used Display Mode. The (PV) display shows the temperature
inside to cooking chamber. The (SV) display shows the target
temperature of the cooking chamber.
Display Mode 2.
It you want to watch the controller in action place the controller in Display
Mode 2. When in Display Mode 1, press/release the
SET KEY
to enter
Display Mode 2
. The (PV) display shows the temperature inside the
cooking chamber. The (SV) display changes to show the auger’s output
as a % of the cycle time (t). Example: If the (SV) display is “A 60”, the
“60” indicates the Auger is running 60% of the cycle time. This value may
change at the start of each cycle. The “A” in the display indicates the
controller is in the “Automatic Control Mode”.
Pressing the
A/M KEY
will switch the controller to “Manual Control
Mode”. When in Manual Control Mode, the first digit to the left will
change to an “M” to indicate Manual Control Mode. Refer to the Section
5.1 Control Modes on the use of “Manual Control Mode”
Display Mode 3.
When in
Display Mode 1
, press/hold the
SET KEY
for 2 seconds to
enter
Display Mode 3.
Display Mode 3 is where the values of the
various operation parameters can be manually changed. The (PV)
display shows the parameter name, the (SV) display is the current value.
Use ▲ and ▼ to modify the current value. Press/release the SET KEY
to advance to the next parameter. After the last parameter is displayed,
press/release the SET KEY to exit Display Mode 3.
4.4
Using the Auger Bypass Feature.
Press/release the
AUG KEY
to run the Auger continuously bypassing
the Control Modes. The (SV) display will flash “ACC” and the last set
temperature when the Auger Bypass feature is being used.
Press/release again to return to normal operation. The Auger Bypass
feature is typically used for high temp grilling or to raise the grill’s
temperature more quickly than Automatic Mode.
Caution: When using Auger Bypass Mode the cooking
chamber, drip tray, and the grease drain system
should be clean. Cooking at high temperatures
increases the risk of having a grease fire. Never leave
the grill unattended. Always return the auger to normal
operation before turning off the grill.
4.5
Changing the Fan Speed
Place the controller in Display Mode 3.
Press/release the SET key to page to parameter
FanS
.
Use the ▲ and ▼keys to modify the current value.
3 is normal fan speed, 2 is medium fan speed and 1 is slow fan speed.
Medium Fan Speed is great to use when smoking below 225° or when
using the STOKER below 250°. Limit the use of the low fan speed for
cold smokin’.On low fan speed the risk of losing fire is greatly increased.
Note: Always return the Fan Speed to normal for cool down.
This space is provided for your notes:
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________