Version 1.0
[
50
]
SAV 243.01 /.07 /.10 /.11
SAV 220.30 /.31 /.32
6 OPERATION
6.1
Clamp
■
Remove any burrs and uneven areas on the workpiece contact surface to ensure that the workpiece
rests against the plate as evenly as possible.
■
Wipe the pole plate of the magnet and the contact surface of the workpiece clean.
■
Position the workpiece.
■
Switch on the magnet with the control lever (Allen key) in the
+
direction.
Ensure that the full control angle has been actuated.
Fig. 10: Switching on the magnet (“+”)
NOTE!
For magnetic chucks with two control levers, two areas of the magnetic
chuck can be switched independently, e.g. for several workpieces or
workpieces with different sizes.
■
Check for sufficient holding force, e.g. carefully try to release the workpiece from the magnet by hand.
■
Close the shielding.
■
Machine the workpiece.
6.2
Releasing
■
When using the magnet vertically, secure the workpiece against falling.
■
Switch off the magnet with the control lever (Allen key) in the
-
direction.
Ensure that the full control angle has been actuated.
Fig. 11: Switching off the magnet (“-”)
■
Remove the workpiece.
■
If the workpiece still adheres due to residual remanence (for tool steel), use light taps to release it
from the magnet.
Summary of Contents for 220.3
Page 55: ......