Instruction manual 
Motorized vertical test stand  
with stepper engine 

 

 

 

 

SAUTER TVO-S  

Version 1.0 
03/2017 
GB

 

 

 

 

TVO-S-BA-e-1710 

 PROFESSIONAL MEASURING 

Summary of Contents for TVO-S Series

Page 1: ...gen E mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction manual Motorized vertical test stand with stepper engine SAUTER TVO S Version 1 0 03 2017 GB TVO S BA e 1710 PROFESSIONAL MEASURING ...

Page 2: ...test stand and its multiple functionalities If you have any suggestions questions or doubts we are ready to assist you Contents 1 General information 3 2 Features 3 3 Technical data 3 4 Scope of supply 3 5 Weight and packaging 4 6 Functions 4 6 1 Operator panel 4 7 Check before use 5 8 Applications 5 9 Operating instructions 6 9 1 Manual automatic test 6 9 2 Speed adjustment 6 9 3 Preset number of...

Page 3: ...maximum force generated by the models is 500 N 1000 N and 2000N respectively Motorized vertical test stands are used primarily for tension and compression testing in material property analyses Their solid design makes them very stable An operator panel placed di rectly on the device facilitates quick set up and testing 3 Technical data Model Max tension compr force Speed range Max travelling dista...

Page 4: ... Main switch Switching on off the test stand Direction switch UP Movement up when the switch is pressed the force measuring device moves up Direction switch DOWN Movement down when the switch is pressed the force measuring device moves down STOP button Stop of movement in the automatic mode Speed adjustment knob Speed adjustment Manual automatic mode Selection between movement in the manual or aut...

Page 5: ...ith a set number of repetitions up to 1 000 TVO S test stands are suitable for material testing in the metal plastic and textile industries They are compatible with SAUTER software AFH which makes it possible to control the movement of the test stand via a computer Other software functions include re cording of the force time and distance covered Operation with the emergency stop option is only po...

Page 6: ...et the speed place the speed adjustment knob in the required position 9 3 Preset number of cycles The test stand has a function for setting the number of cycles The preset number of cycles is shown in the bottom display and can be adjusted using three buttons Counter Counter or Selection of counter position The actual number of cy cles is shown in the top display The displays can be reset with the...

Page 7: ...ent the penetration of liquids into the metal motor enclosure When not in use the test stand should be stored in a dry and dust free place 11 Warnings Incorrect measurements of force may result in serious body injury and property dam age Consequently force measurements should only be performed by properly trained and experienced personnel In particular make sure that the test stand does not affect...