Overloads  

Please prevent the measuring instrument from being overloaded beyond the specified 
maximum  load  (Max),  minus  any  tare  load  that  may  already  be  present.  This  can 
damage the measuring instrument (danger of breakage!). 
 

Attention: 

-  Make sure that there are never people or objects under the load, as they could be 

injured or damaged!  

-  The measuring  instrument  is not  suitable for  weighing  people,  do not  use  it as an 

infant measuring instrument!  

-  The measuring device does not comply with the German Medical Devices Act (MPG). 
-  Never operate the measuring instrument in rooms where there is a risk of explosion. 

The standard version is not explosion-proof.  

-  The  design  of  the  measuring  instrument  must  not  be  changed.  This  can  lead  to 

incorrect  measurement  results,  safety-related  defects  and  the  destruction  of  the 
measuring device.  

-  The measuring instrument may only be operated or maintained by trained personnel. 
-  The  measuring  instrument  may  only  be  used  in  accordance  with  the  described 

specifications. 

-  SAUTER must give written approval for any other areas of use / applications. 

 

Warranty 

Warranty expires in case of 
- not following our guidelines in the operating instructions 
- use outside the described field of application 
- Modifying or opening the device 
- mechanical damage and damage caused by agents such as liquids or liquids  
 have been caused 
- improper assembly or electrical installation 
- Overloading the measuring cell 

 

 

Summary of Contents for FK 10

Page 1: ...GmbH Ziegelei 1 D 72336 Balingen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction manual digital force gauge SAUTER FK Version 2 0 01 2020 GB PROFESSIONAL MEASURING ...

Page 2: ... measuring device with a wide range of functions Please do not hesitate to contact us if you have any questions requests or suggestions Table of contents Introduction 3 Scope of delivery 3 Technical data 4 3 1 Technical data FK with internal loadcell up to 500N 4 Battery operation power supply 5 Display indication 5 Control buttons 5 Inverting the display by 180 6 Warnings 6 Adjustment instruction...

Page 3: ...c housing other parts or even the gauge itself have not been damaged If any damage is evident please notify SAUTER GmbH immediately SAUTER offers optional software and accessories to make the measuring instrument more versatile in use Please ask SAUTER or the SAUTER supplier or visit our website www sauter eu Scope of delivery SAUTER FK Power supply Delivered in stable cardboard packaging 5 pieces...

Page 4: ...l loadcell up to 500N Measuring device FK 10 FK 25 FK 50 FK 100 FK 250 FK 500 FK 1k Capacity 10N 25N 50N 100N 250N 500N 1000N Work temperature 10 C to 30 C Relative air humidity 15 to 80 Humidity Weight Approx 720g Dimensions Display unit LxWxH 195x82x35mm Thread M8 ...

Page 5: ...lay indication 4 Position Description 1 Measurement result 2 Display unit of the measurement result 3 Measuring direction push pull 4 Display of the PEAK peak measured value mode Control buttons ON OFF On Off button press button for approx 1 s MAX Change to PEAK peak mode UNIT units of measurement Press the key briefly Selection between N kg lb and oz ZERO Reset Assignment with three functions Zer...

Page 6: ...hat do not act axially on the instrument via the load cell or if high impulse forces act on the measuring instrument Avoid twisting the loadcell otherwise it could be damaged and the measuring accuracy will decrease in any case Inappropriate use Do not use the measuring instrument for medical weighing If small quantities of the material to be measured are removed or added incorrect measurement res...

Page 7: ...osion The standard version is not explosion proof The design of the measuring instrument must not be changed This can lead to incorrect measurement results safety related defects and the destruction of the measuring device The measuring instrument may only be operated or maintained by trained personnel The measuring instrument may only be used in accordance with the described specifications SAUTER...

Page 8: ...rpose as well as the type and scope of this inspection Information on the monitoring of measuring instruments and the necessary test weights is available on the SAUTER homepage www sauter eu The weights and measuring instruments can be checked and adjusted quickly and at favourable prices in KERN s accredited DAkkS laboratory traceability to the national standard Note To view the CE declaration pl...

Page 9: ...commended for stabilisation The FK can be switched on by pressing the ON OFF key The unit is in a hanging position 2 When the display shows 0 press the UNIT button and the ZERO button simultaneously until CAL appears on the display 3 After a few seconds the display will show the required calibration weight e g 5 00kg for the FK 50 or 10 00kg for the FK 100 ...

Page 10: ... shaking Tip hold the device with both hands while both elbows are resting on a table or attach it to a solid object test bench 5 This position is held until F appears on the display Then the weight can be removed and the adjustment is completed However if E appears on the display repeat steps 1 to 5 until F confirms successful adjustment ...

Page 11: ...FK BA e 2020 11 Technical drawings Dimensions in mm LCD 195 83 Force measurement sensor M8 thread ...

Reviews: