FK-BA-e-2020 

 

 

Introduction 

Please read these operating instructions carefully before commissioning, even if you 
already have experience with SAUTER measuring instruments. 
After  receipt  of  the  force  gauge,  it  should  be  checked  in  advance  that  no  transport 
damage  has  occurred,  that  the  outer  packaging,  the  plastic  housing,  other  parts  or 
even the gauge itself have not been damaged. If any damage is evident, please notify 
SAUTER GmbH immediately. 
 
SAUTER offers optional software and accessories to make the measuring instrument 
more versatile in use. Please ask SAUTER or the SAUTER supplier or visit our website 

www.sauter.eu.

 

 

Scope of delivery 

 

-  SAUTER FK 
-  Power supply 
-  Delivered in stable cardboard packaging 
-  5 pieces M3x8 screws for mounting on SAUTER test benches 
-  Standard attachments as standard, as shown 

extension bar: 90mm 

 

 

Summary of Contents for FK 10

Page 1: ...GmbH Ziegelei 1 D 72336 Balingen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction manual digital force gauge SAUTER FK Version 2 0 01 2020 GB PROFESSIONAL MEASURING ...

Page 2: ... measuring device with a wide range of functions Please do not hesitate to contact us if you have any questions requests or suggestions Table of contents Introduction 3 Scope of delivery 3 Technical data 4 3 1 Technical data FK with internal loadcell up to 500N 4 Battery operation power supply 5 Display indication 5 Control buttons 5 Inverting the display by 180 6 Warnings 6 Adjustment instruction...

Page 3: ...c housing other parts or even the gauge itself have not been damaged If any damage is evident please notify SAUTER GmbH immediately SAUTER offers optional software and accessories to make the measuring instrument more versatile in use Please ask SAUTER or the SAUTER supplier or visit our website www sauter eu Scope of delivery SAUTER FK Power supply Delivered in stable cardboard packaging 5 pieces...

Page 4: ...l loadcell up to 500N Measuring device FK 10 FK 25 FK 50 FK 100 FK 250 FK 500 FK 1k Capacity 10N 25N 50N 100N 250N 500N 1000N Work temperature 10 C to 30 C Relative air humidity 15 to 80 Humidity Weight Approx 720g Dimensions Display unit LxWxH 195x82x35mm Thread M8 ...

Page 5: ...lay indication 4 Position Description 1 Measurement result 2 Display unit of the measurement result 3 Measuring direction push pull 4 Display of the PEAK peak measured value mode Control buttons ON OFF On Off button press button for approx 1 s MAX Change to PEAK peak mode UNIT units of measurement Press the key briefly Selection between N kg lb and oz ZERO Reset Assignment with three functions Zer...

Page 6: ...hat do not act axially on the instrument via the load cell or if high impulse forces act on the measuring instrument Avoid twisting the loadcell otherwise it could be damaged and the measuring accuracy will decrease in any case Inappropriate use Do not use the measuring instrument for medical weighing If small quantities of the material to be measured are removed or added incorrect measurement res...

Page 7: ...osion The standard version is not explosion proof The design of the measuring instrument must not be changed This can lead to incorrect measurement results safety related defects and the destruction of the measuring device The measuring instrument may only be operated or maintained by trained personnel The measuring instrument may only be used in accordance with the described specifications SAUTER...

Page 8: ...rpose as well as the type and scope of this inspection Information on the monitoring of measuring instruments and the necessary test weights is available on the SAUTER homepage www sauter eu The weights and measuring instruments can be checked and adjusted quickly and at favourable prices in KERN s accredited DAkkS laboratory traceability to the national standard Note To view the CE declaration pl...

Page 9: ...commended for stabilisation The FK can be switched on by pressing the ON OFF key The unit is in a hanging position 2 When the display shows 0 press the UNIT button and the ZERO button simultaneously until CAL appears on the display 3 After a few seconds the display will show the required calibration weight e g 5 00kg for the FK 50 or 10 00kg for the FK 100 ...

Page 10: ... shaking Tip hold the device with both hands while both elbows are resting on a table or attach it to a solid object test bench 5 This position is held until F appears on the display Then the weight can be removed and the adjustment is completed However if E appears on the display repeat steps 1 to 5 until F confirms successful adjustment ...

Page 11: ...FK BA e 2020 11 Technical drawings Dimensions in mm LCD 195 83 Force measurement sensor M8 thread ...