background image

8

G  

EGH110F941 | EGH112F931 | EGH111F931 

Rev.  2021 - V27

Type ⁄ Code

Measuring range 

humidity 

temperature

Output

 

 

humidity 

temperature

EGH110F941

0...100 %  r. H.

–35...+75 °C 
–35...+35 °C 
  0...+50 °C 
  0...+80 °C

4...20  mA

4...20  mA

EGH111F931

0...100 %  r. H.

(4 x   as  above)

0 - 10  V

0 - 10  V  + 

Ni1000 (passive)

EGH112F931

0...100 %  r. H.

(4 x   as  above)

0 - 10  V

0 - 10  V

Calibratable duct humidity- ⁄ temperature sensor, with plastic sinter filter, housing made of  impact-resistant plastic with quick-locking screws, with 
cable gland. It measures the relative humidity and ⁄ or the temperature of the air and converts the measurands into a standard signal of 0 - 10 V  
or  4...20 mA. It has four switchable temperature ranges and is applied in non-aggressive dust-free atmospheres in refrigeration, air conditioning, 
ventilation and clean room technology. These measuring transducers are designed for exact detection of humidity. A digital long-term stable sensor 
is used as measuring element for humidity measurement. The sensor is factory-calibrated; an environmental precision adjustment by an expert is 
possible. 

TECHNICAL DATA

Power supply:  

24 V AC  (± 20 %);  15...36 V DC  for EGH11xF931 variant 
15...36 V DC  for EGH110F941 variant, depending on working resistance, residual ripple stabilised ± 0.3 V

Working  resistance: 

Ra (ohm)   =   (Ub -14 V)   ⁄   0.02 A    for EGH110F941 variant  (see load resistance diagram)

Load resistance: 

R

L

 > 5 kOhm  for EGH11xF931 variant

Power consumption: 

< 1.1 VA  ⁄  24 V DC ;  < 2.2 VA  ⁄  24 V AC

Sensors: 

digital humidity sensor with integrated temperature sensor,

  

low hysteresis, high long-term stability

HUMIDITY

Measuring range, humidity: 

0...100 % r. H.

Permissible air humidity:  

< 95 %  r. H., non-precipitating air

Deviation, humidity: 

typically 

± 2.0 % 

(20...80 %  r. H.)  at  +25 °C,  otherwise  ± 3.0 % 

Output, humidity: 

0 - 10 V  or    4...20  mA

TEMPERATURE

Measuring range, temperature: 

multi-range switching with 4 switchable measuring ranges  

(see table)

 

–35...+35 °C;  –35...+75 °C;  0...+50 °C;  0...+80 °C 

Ambient temperature: 

storage –35...+85 °C;  operation – 30...+75 °C, non-precipitating

Deviation,  temperature:  

typically  ± 0.2 K  at  +25 °C

Output, temperature: 

0 - 10 V  or    4...20  mA; 

EGH111F931

 (passive temperature sensor) see table

Electrical connection: 

3-, 4-, or 6-wire connection (see connecting diagram),  
0.14   -  1.5 mm²,  via  terminal  screws

Cable connection: 

cable gland, plastic  
(M 16 x 1.5; exchangeable, max. inner diameter 10.4 mm)

Housing: 

plastic, UV-resistant, material polyamide, 30 % glass-globe reinforced,  
with quick-locking screws (slotted ⁄ Phillips head combination),  
colour traffic white (similar to RAL 9016)

Housing  dimensions:  

72  x  64  x  37.8 mm

Protective tube: 

material polyamide (PA6), with torsion protection 
Ø  20 mm,  NL = 235 mm,  v

max

 = 30  m/s (air) 

Sensor protection: 

plastic

 

sinter filter, Ø 16 mm, L = 35 mm, exchangeable 

Process connection: 

by mounting flange, plastic (included in the scope of delivery)

Long-term  stability: 

± 1 %   per  year

Protection class: 

III  (according to EN 60 730)

Protection type: 

IP 65

  (according to EN 60 529)   

Housing tested, TÜV SÜD, Report No. 713139052

Standards: 

CE conformity, according to EMC directive 2014 ⁄ 30 ⁄ EU, 
according to EN 61326-1, according to EN 61326-2-3

Summary of Contents for EGH110F941

Page 1: ...ruction Sonde d humidité et de température 2 0 pour montage en gaine y compris bride de montage étalonnable avec commutation multi gamme et sortie active passive I Istruzioni per l uso e per il montaggio Sonde per canale di umidità e temperatura 2 0 incl flangia di montaggio calibrabili con diverse opzioni di configurazione e uscita attiva passiva CARTONS ET EMBALLAGE PAPIER À TRIER MADE IN GERMAN...

Page 2: ... 2 ø20 200 ø 4 3 14 8 37 8 M16x1 5 13 4 37 8 39 49 107 72 64 ø32 3 12 Montageflansch aus Kunststoff Mounting flange plastic Bride de montage en matière plastique Flangia di montaggio in plastica Kunststoff Sinterfilter Plastic sinter filter Filtre fritté en matière synthétique Filtro sinterizzato in plastica EGH110F941 EGH11xF931 ...

Page 3: ...xF931 Leistungsaufnahme 1 1 VA 24 V DC 2 2 VA 24 V AC Sensoren digitaler Feuchtesensor mit integriertem Temperatursensor kleine Hysterese hohe Langzeitstabilität FEUCHTE Messbereich Feuchte 0 100 r H zulässige Luftfeuchte 95 r H nicht kondensierende Luft Abweichung Feuchte typisch 2 0 20 80 r H bei 25 C sonst 3 0 Ausgang Feuchte 0 10 V oder 4 20 mA TEMPERATUR Messbereich Temperatur Mehrbereichsums...

Page 4: ...fset C r H UB 24V DC Ausgang Feuchte r H 4 20mA Ausgang Temperatur C 4 20mA UB GND passiver Sensor DIP Schalter Mehrbereichs umschaltung Offset Temperatur 5 K Feuchte 10 r H Anschlussbild EGH111F931 passiver Temperatursensor 1 2 3 4 5 6 passives Element Ni1000 UB GND Ausgang Temperatur C 0 10V Ausgang Feuchte r H 0 10V UB 24V AC DC Anschlussbild EGH110F941 Transmitter 1 2 3 4 UB GND Ausgang Temper...

Page 5: ...Temperaturtabelle MB 35 75 C C UA in V IA in mA 35 0 0 4 0 30 0 5 4 7 25 0 9 5 5 20 1 4 6 2 15 1 8 6 9 10 2 3 7 6 5 2 7 8 4 0 3 2 9 1 5 3 6 9 8 10 4 1 10 5 15 4 5 11 3 20 5 0 12 0 25 5 5 12 7 30 5 9 13 5 35 6 4 14 2 40 6 8 14 9 45 7 3 15 6 50 7 7 16 4 55 8 2 17 1 60 8 6 17 8 65 9 1 18 5 70 9 5 19 2 75 10 0 20 0 Temperaturtabelle MB 35 35 C C UA in V IA in mA 35 0 0 4 0 30 0 7 5 1 25 1 4 6 3 20 2 1...

Page 6: ...etriebsspannung ist bei dieser Gerätevariante eine Einweggleichrichtung bzw Verpolungschutzdiode integriert Diese interne Einweggleichrichtung erlaubt auch den Betrieb mit AC Versor gungsspannung bei 0 10 V Geräten Das Ausgangssignal ist mit einem Messgerät abzugreifen Hierbei wird die Ausgangsspannung gegen das Nullpotenial O V der Eingangsspannung ge messen Wird dieses Gerät mit DC Versorgungssp...

Page 7: ... Gerät z B durch Spannungsinduktion zu verhindern sind abgeschirmte Leitungen zu verwenden eine Parallelverlegung zu stromführenden Leitungen zu vermeiden und die EMV Richtlinien zu beachten Dieses Gerät ist nur für den angegebenen Verwendungszweck zu nutzen dabei sind die entsprechenden Sicherheitsvorschriften der Länder ihrer Überwachungsorgane des TÜV und der örtlichen EVU zu beachten Der Käufe...

Page 8: ...A 24 V AC Sensors digital humidity sensor with integrated temperature sensor low hysteresis high long term stability HUMIDITY Measuring range humidity 0 100 r H Permissible air humidity 95 r H non precipitating air Deviation humidity typically 2 0 20 80 r H at 25 C otherwise 3 0 Output humidity 0 10 V or 4 20 mA TEMPERATURE Measuring range temperature multi range switching with 4 switchable measur...

Page 9: ...5 6 1 2 0N Offset C r H DIP switches multi range switching Passive sensor Offset Temperature 5 K Humidity 10 r H UB 24V AC DC Output humidity r H 0 10V Output temperature C 0 10V UB GND 1 2 3 4 5 6 1 2 0N Offset C r H Passive sensor DIP switches multi range switching Offset Temperature 5 K Humidity 10 r H UB 24V DC Output humidity r H 4 20mA Output temperatur e C 4 20mA UB GND 1 2 3 4 5 6 Passive ...

Page 10: ... 8 8 18 0 75 9 4 19 0 80 10 0 20 0 Temperature table MR 35 75 C C UA in V IA in mA 35 0 0 4 0 30 0 5 4 7 25 0 9 5 5 20 1 4 6 2 15 1 8 6 9 10 2 3 7 6 5 2 7 8 4 0 3 2 9 1 5 3 6 9 8 10 4 1 10 5 15 4 5 11 3 20 5 0 12 0 25 5 5 12 7 30 5 9 13 5 35 6 4 14 2 40 6 8 14 9 45 7 3 15 6 50 7 7 16 4 55 8 2 17 1 60 8 6 17 8 65 9 1 18 5 70 9 5 19 2 75 10 0 20 0 Temperature table MR 35 35 C C UA in V IA in mA 35 0...

Page 11: ...f the input voltage When this device is operated on DC supply voltage the operating voltage input UB is to be used for 15 36 V DC supply and UB or GND for ground wire When several devices are supplied by one 24 V AC voltage supply it is to be ensured that all positive operating voltage input terminals of the field devices are connected with each other and all negative operating voltage input termi...

Page 12: ...To avoid damages and errors at the device e g by voltage induction shielded cables are to be used laying parallel with current carrying lines is to be avoided and EMC directives are to be observed This device shall only be used for its intended purpose Respective safety regulations issued by the states their control authorities the TÜV and the local energy supply company must be observed The purch...

Page 13: ...e RL 5 kOhm pour variante EGH11xF931 Puissance absorbée 1 1 VA 24 V cc 2 2 VA 24 V ca Capteurs capteur d humidité numérique avec capteur de température intégré petite hystérésis stabilité à long terme HUMIDITÉ Plage de mesure humidité 0 100 h r Humidité d air admissible 95 h r sans condensation de l air Écart humidité typique 2 0 20 80 h r à 25 C sinon 3 0 Sortie humidité 0 10 V or 4 20 mA TEMPÉRA...

Page 14: ...ité pin 2 1 2 3 4 5 6 1 2 0N Offset C r H DIP switches multi range switching Passive sensor Offset Temperature 5 K Humidity 10 r H UB 24V AC DC Output humidity r H 0 10V Output temperature C 0 10V UB GND 1 2 3 4 5 6 1 2 0N Offset C r H Passive sensor DIP switches multi range switching Offset Temperature 5 K Humidity 10 r H UB 24V DC Output humidity r H 4 20mA Output temperatur e C 4 20mA UB GND 1 ...

Page 15: ... 75 9 4 19 0 80 10 0 20 0 Tableau de température plage de mesure 35 75 C C UA en V IA en mA 35 0 0 4 0 30 0 5 4 7 25 0 9 5 5 20 1 4 6 2 15 1 8 6 9 10 2 3 7 6 5 2 7 8 4 0 3 2 9 1 5 3 6 9 8 10 4 1 10 5 15 4 5 11 3 20 5 0 12 0 25 5 5 12 7 30 5 9 13 5 35 6 4 14 2 40 6 8 14 9 45 7 3 15 6 50 7 7 16 4 55 8 2 17 1 60 8 6 17 8 65 9 1 18 5 70 9 5 19 2 75 10 0 20 0 Tableau de température plage de mesure 35 3...

Page 16: ...r rapport au potentiel zéro O V de la tension d entrée Si cet appareil est alimenté en courant continu il faut utiliser l entrée de tension de service UB pour l alimentation en 15 36 V cc et UB ou GND comme câble de masse Si plusieurs appareils sont alimentés en 24V ca il faut veiller à ce que toutes les entrées de tension positives des appareils de terrain soient reliées entre elles de même que t...

Page 17: ...r des endommagements erreurs sur l appareil par ex dus à une induction de tension parasite il est conseillé d utiliser des câbles blindés ne pas poser les câbles de sondes en parallèle avec des câbles de puissance les directives CEM sont à respecter Cet appareil ne doit être utilisé que pour l usage qui est indiqué en respectant les règles de sécurité correspondantes des Länders de leurs organes d...

Page 18: ... VA 24 V DC 2 2 VA 24 V AC Sensori sensore di umidità digitale con sensore di temperatura integrato bassa isteresi alta stabilità a lungo termine UMIDITÀ Range di misura umidità 0 100 u r Umidità dell aria consentita 95 u r aria senza condensa Accuratezza umidità tipico 2 0 20 80 u r a 25 C altrimenti 3 0 Uscita umidità 0 10 V o 4 20 mA TEMPERATURA Range di misura temperatura diverse opzioni di co...

Page 19: ...iva morsetto 2 1 2 3 4 5 6 1 2 0N Offset C r H DIP switches multi range switching Passive sensor Offset Temperature 5 K Humidity 10 r H UB 24V AC DC Output humidity r H 0 10V Output temperature C 0 10V UB GND 1 2 3 4 5 6 1 2 0N Offset C r H Passive sensor DIP switches multi range switching Offset Temperature 5 K Humidity 10 r H UB 24V DC Output humidity r H 4 20mA Output temperatur e C 4 20mA UB G...

Page 20: ...abella temperatura MB 35 75 C C UA in V IA in mA 35 0 0 4 0 30 0 5 4 7 25 0 9 5 5 20 1 4 6 2 15 1 8 6 9 10 2 3 7 6 5 2 7 8 4 0 3 2 9 1 5 3 6 9 8 10 4 1 10 5 15 4 5 11 3 20 5 0 12 0 25 5 5 12 7 30 5 9 13 5 35 6 4 14 2 40 6 8 14 9 45 7 3 15 6 50 7 7 16 4 55 8 2 17 1 60 8 6 17 8 65 9 1 18 5 70 9 5 19 2 75 10 0 20 0 Tabella temperatura MB 35 35 C C UA in V IA in mA 35 0 0 4 0 30 0 7 5 1 25 1 4 6 3 20 ...

Page 21: ...a La tensione di uscita viene misurata rispetto al potenziale zero O V della tensione di ingresso Quando questo dispositivo viene utilizzato con tensione di alimentazione DC l ingresso della tensione di esercizio UB deve essere utilizzato per l alimentazione 15 36 V DC e l ingresso UB o GND per la terra Quando più dispositivi sono alimentati da un unica alimentazione con ten sione 24 V AC è necess...

Page 22: ...senza di tensione Per evitare danni ed errori negli apparecchi dovuti ad es all induzione elettrica utilizzare cavi schermati evitare la posa in parallelo delle linee conduttrici di corrente e rispettare le norme di compatibilità elettromagnetica Utilizzare questo apparecchio esclusivamente allo scopo indicato Rispettare le norme di sicurezza del rispettivo paese del TÜV e delle imprese locali di ...

Reviews: