4
CT Q1-BA-e-1810
5
Warranty
The warranty expires at:
Disregard of the specifications of the operating manual
Modification or opening the measuring cell
Overload
Mechanical damages
Damage caused by liquids or media
Natural loss
Not correct installation
6
Detailed specifications
Output sensitivity ( FS )
mV/V
2.0 ± 0.001
Maximum capacity ( Emax )
kg
300, 500, 750, 1000, 1500, 2000, 3000,
5000, 7500, 10000
Max.number of load cell
intervals
nLC
3000
Ratio of min. LC verification
interval
Y = Emax
/ vmin
10000
Combined Error
%FS
≤± 0.017
Minimum dead load
Of Emax
0%
Safe overload
of Emax
150 %
Ultimate overload
of Emax
200 %
Zero balance
of FS
< ± 2.0 %
Excitation, recommended
voltage
V
10 ~ 15
Input resistance
Ω
400 ± 20
Output resistance
Ω
350 ± 3
Insulation resistance
MΩ
≥5000 ( at 50VDC )
Compensated temperature
°C
-10 ~+40
Operating temperature
°C
-35 ~ +65
7
Wiring
Shielded, 6 cable. Shield not connected to element.
Cable diameter: Ø6mm.
Standard cable length for 300kg
– 5000kg: 5m
Standard cable length for 7500kg
– 10000kg: 10m
6-wire diagram
Input(+)
Sense(+)
Output(-)
Sense(-)
Input(-)
)
Green
Blue
White
Yellow
Black
Red