background image

CT Q1-BA-e-1810 

 

 

Short description 

  Stainless steel IP68 (acc. to EN 60529) / IP69K (acc. to ISO 20653) shear 

beam load cell  

  Suitable platform, hopper, bed  and other weighing devices in raw 

environment 

  hermetically sealed 

  Accuracy OIML R60 C3 

  OIML certificated 

  RoHS conform  

  Option on request: EX

 

Available models 

Capacity 

Model 

300kg 

CT 300-3Q1 

500kg 

CT 500-3Q1 

750kg 

CT 750-3Q1 

1000kg 

CT 1000-3Q1 

1500kg 

CT 1500-3Q1 

2000kg 
 

CT 2000-3Q1 

3000kg 

CT 3000-3Q1 

5000kg 

CT 5000-3Q1 

7500kg 

CT 7500-3Q1 

10000kg 

CT 10000-3Q1 

 

Introduction 

Please pay attention to the notes of the operating manual: read these operating 
manual carefully before commissioning, even if you already have experience with 
SAUTER measuring cells. 
After receiving the measuring cell, it should be checked in advance whether no 
transport damage has occurred, whether the outer packaging or other parts or even 
the article itself has been damaged. If any damage is evident, please inform 
SAUTER GmbH immediately. 

Warning notes 

Observe the national accident prevention regulations. 
Not correct executed use of the measuring cell can lead to serious injuries, death, 
material damage and personal injuries. Use only by trained and experienced people. 
Never load more than the max. capacity to a measuring cell. Overloaded measuring 
cells no longer have the required accuracy. Overloaded or deformed measuring cells 
are no longer allowed to use and must be changed quickly. 
Never step under suspended loads.  
Always fasten overload- or break security to your construction. 
Pay attention to the allowed static and dynamic loads of the used equipment. 
Let the measuring cells calibrate at regular intervals.  
Only load the measuring cell in its specified load direction. Avoid lateral forces.  
Control the measuring cells to deformations and cracks. 
Measuring cells with 4-Conductor cable will change their characteristic value when 
shortened or extended the cable length.  
 

Summary of Contents for CT Q1

Page 1: ...Sauter GmbH Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Data sheet CT Q1 V 1 0 12 2018 EN CT Q1 BA e 1810 ...

Page 2: ...a sheet Summarize 1 Short description 3 2 Available models 3 3 Introduction 3 4 Warning notes 3 5 Warranty 4 6 Detailed specifications 4 7 Wiring 4 8 Dimensions in mm 5 8 1 Dimensions in mm 300kg 5000kg 5 8 2 Dimensions in mm 7500kg 10000kg 5 9 Certificate of Compliance 5 ...

Page 3: ... parts or even the article itself has been damaged If any damage is evident please inform SAUTER GmbH immediately 4 Warning notes Observe the national accident prevention regulations Not correct executed use of the measuring cell can lead to serious injuries death material damage and personal injuries Use only by trained and experienced people Never load more than the max capacity to a measuring c...

Page 4: ... Ratio of min LC verification interval Y Emax vmin 10000 Combined Error FS 0 017 Minimum dead load Of Emax 0 Safe overload of Emax 150 Ultimate overload of Emax 200 Zero balance of FS 2 0 Excitation recommended voltage V 10 15 Input resistance Ω 400 20 Output resistance Ω 350 3 Insulation resistance MΩ 5000 at 50VDC Compensated temperature C 10 40 Operating temperature C 35 65 7 Wiring Shielded 6 ...

Page 5: ... 10000kg 9 Certificate of Compliance The Certificate of Compliance can be downloaded from the website www sauter eu Dimension Capacity A B C D E F G Ø H I J K L M N Ø 300kg 2000kg 31 5 15 24 6 56 31 5 130 13 5 18 M12 76 2 25 4 15 8 6 5 3 5 3000kg 5000kg 48 37 79 41 5 171 5 20 5 18 20 5 95 2 38 1 19 ...

Reviews: