3. INSTALLATION INSTRUCTIONS

3.1. Before installation

Installation of the sauna climate device must be performed by a qualified electrician. The unit must be permanently connected with a cable that is suited for the tempera

-

ture conditions of the environment. A protective earth (PE) connection with conductors of at least 2.5 mm2 must be connected to the connection terminal of the device. 

The power for the device must be taken from the power circuit of the control device, which is protected by overcurrent fuses. The required sizes of overcurrent fuses and 

connection cable dimensions are given in 

Table 1 

(page 16). All certified sauna controller devices with the sufficient capacity for the Saunum H-1 model in accordance with 

Table 1 (page 16) can be used to control the sauna climate device.

Before beginning installation, read the installation instructions and pay attention to the following:

•  Power and type of heater are suitable for the given steam room. The recommended steam room volume is given in 

Table 1

 (page 16).

•  The supply voltage is suitable for the sauna climate device.

•  The minimum installation safety distances measured from the heater housing at the installation location of the sauna climate device meet therequirements 

    specified in table

• The dimensions of the device are shown in 

Figure 3.1

.

• Also, make sure that the upper edge of the fan outlet of the sauna climate device is lower than the lower edge of the bench. There must be no obstructions in 

  front of the air outlet of the device; the exhaust air stream must be able to circulate freely over the steam room.

The device works most effectively when its flue cap is mounted to the ceiling of the steam room and the exhaust air is blown under the bench. However, the device must 

not be positioned so that the upper edge of the heater is higher than 80 cm from the floor. The device is designed for wall mounting with 6 mm (lower part) and 5 mm 

(flue cap) bolts. At the installation site of a sauna climate device, the wall must withstand the weight of the device (at least 80 kg). The type of anchor bolts should be 

selected according to the characteristics of the load-bearing structure at the installation site. The method of mounting must ensure that the device remains firmly on the 

wall.

The safety distance requirements must be complied with unconditionally, as failure to do so will result in a fire hazard. 

Only one sauna climate device may be installed in the steam room.

3.2. Wall mounting of the sauna climate unit.

See Figures 3.2 to 3.8.

3.2.1. 

Loosen the four fixing screws holding the flue socket and remove the flue socket (

Figure 3.2

).

3.2.2 

Turn the bolts in the middle fixing holes of the wall leaving them unturned by 5 mm (

Figure 3.3

).

3.2.3. 

Then, lift the device on the wall so that the bolts in the wall slide into the openings on the back of the device (

Figure 3.4

).

3.2.4. 

Screw the fixing bolts into the upper and lower mounting holes and secure the unit to the wall, then tighten the lower mounting bolts to the end (

Figure 3.5

).

3.2.5. 

Put the flue socket back and secure with four screws (

Figure 3.6

). 

3.2.6. 

Attach the flue cap under the sauna room ceiling using two 5 mm bolts (

Figure 3.7

). NB! Align the flue cap with the flue opening in the flue socket!.

3.2.7. 

Put the lower end of the flue on the flue socket.

3.2.8. 

Hang the upper part of the flue to the flue cap so that the upper part of the flue is connected to the lower part of the flue (

Figure 3.8

).

3.2.9. 

Connect the sauna climate device to the control device (

Section 3.3

). 

3.2.10. 

Fill the stone room of the sauna climate device with heater stones (

Section 1.6

).

Summary of Contents for H-1/6

Page 1: ...1...

Page 2: ...Saunum s climate system devices H 1 6 and H 1 9 for saunas Instructions for use and installation...

Page 3: ...s of the following directives of the Council of Europe provided that the installation has been conducted pursuant to the installation instructions issued by the producerof the devices and the instruct...

Page 4: ...4 Saunum Saunas LTD congrats you on choosing an innovative sauna climate device...

Page 5: ...control unit shall have the capability to control the fan of the sauna climate device and preferably function to switch off the heater and the fan of the sauna climate device simultaneously To ensure...

Page 6: ...reach the right temperature in a properly isolated sauna room The stones usually heat up to the steam temperature at the same time as the sauna room In order not to raise the surface temperature of th...

Page 7: ...e time the bench does not become hot You can find the best setting for you by experimenting Start testing at lower temperatures and minimum airflow rates If the temperature rises too high during your...

Page 8: ...ve the air outlet grille and place the salt balls in the recesses Figure 5 Do not use start up the device if the salt balls have gotten into the fan housing After installing or removing the salt balls...

Page 9: ...air and humid climate can create oxide coating rust on the metal surfaces of the heater Make sure you have sufficient ventilation in the sauna room Saunum is not responsible for the potential corrosi...

Page 10: ...s to reach the right temperature in a properly isolated sauna room Make sure the ventilation solution used is suitable for the sauna Reduce the fan speed of the sauna climate device The panel or other...

Page 11: ...sauna climate device near the stone room or the fan 1 7 Maintenance Due to the large temperature fluctuations the heater stones tend to crumble The stones should be restacked at least once a year or...

Page 12: ...echanical air extraction is used place the air supply above the sauna climate device If natural air extraction is used place the air supply under or next to the sauna climate device The air inlet pipe...

Page 13: ...st air is blown under the bench However the device must not be positioned so that the upper edge of the heater is higher than 80 cm from the floor The device is designed for wall mounting with 6 mm lo...

Page 14: ...powered from a 380 VAC 3 phase or 230 VAC 1 phase 50 60 Hz power supply via a control device protected by an overcurrent protector of the size shown in table 1 If the device s air circulation fan is...

Page 15: ...15 400 290 290 100 525 750 750 230 max 2100mm DRAWING Figure 3 1 Premium sauna climate system overall dimensions...

Page 16: ...ety distances of the sauna climate device and the recommended location in the steam room Sauna device Volume Saunum H 1 6 6kW 5 9 m3 Saunum H 1 9 9kW 8 15 m3 min 50mm min 75mm min 50mm min 100mm A A A...

Page 17: ...mensions ELECTRIC PANEL STEAM ROOM CONTROL UNIT IP65 FAN HEATING ELEMENTS CONTROL PANEL TEMPERATURE SENSOR LOCATION ACCORDING TO THE MANUFACTURER S REQUIRMENTS DOOR SENSOR 2x 0 34mm 2 OPTIONAL Optiona...

Page 18: ...1 9 CABLE mm2 3 phase 1phase fan SAFETY DISTANCE FROM THE HEATER SAUNA ROOM CUBIC VOL m3 ELECTRIC CIRCUIT DIAGRAM Table 1 DEVICE HOUSING POWER SPEED MOTOR FAN HOUSING HEATER blue yellow green 230 400V...

Page 19: ...19 350 350 7 13 5 350 160 1 2 max 510mm min 310mm FIGURES Figure 3 2 Removing the flue socket Figure 3 3 Installing bolts for middle mounting holes...

Page 20: ...20 4x M6 Figure 3 4 Hanging the sauna climate device on the wall Figure 3 5 Installing the upper and lower mounting bolts and fixing the sauna climate device to the wall FIGURES...

Page 21: ...21 1 2 max 2100mm max 1500mm Figure 3 6 Installation of flue socket on the device and fastening with screws Figure 3 7 Fitting and fastening the flue cap FIGURES...

Page 22: ...22 2 2 3 3 1 1 Figure 3 8 Fitting the flue to the flue socket and hanging it to the flue cap FIGURES...

Page 23: ...23 Figure 4 Opening electrical panel FIGURES...

Page 24: ...24 Figure 5 Opening himalayan salt ball shelf FIGURES...

Page 25: ...25 Placing heating element supporting rods and placing stones in the stove FIGURES...

Reviews: