24
5.7.2 Vertical concentric flue
Ø 60/100
(C33 type installation)
L
Maximum flue index: 150 Pa
This value is reached with the length of
the maximum duct (L) + 1 90° elbow.
Flue model
Max. length
Ø 60/100
6.5 m
Every time an extra 90° elbow is used (or
2 off 45°), the length (L) should be redu-
ced at by 1 m.
5.7.3 Twin flue 2 x Ø 80
(C53 type installation)
L1
L2
L1
188
Maximum flue index: 150 Pa
This value is reached with 2 elbows, the
separator and the maximum duct length
(L1+L2) of 40 m.
Every time an extra 90° elbow is used (or
2 off 45°), the length (L) should be redu-
ced by 2 m.
5.8 Electrical connection
Warning! Incorrect installation can cause
electric shock or appliance damage.
Connect the power cable of the boiler to
the 230 V single-phase + earth network.
Observe the live and neutral connection
on the boiler.
Do not use cable over 10 mm in
diameter for electrical connections.
Important: Electrical connection of the
appliance must be made only by a skilled
professional.
Isolation should be by a double pole
switched fused spur box, with a minimum
gap of 3mm for both poles.
The fuse of the PCB must be connected to
the neutral.
5.8.1 Access to electrical connections
1
2
Legend
1
Access on factory connection side
2
Access on installer connection side
•
•
•
Summary of Contents for ThemaPLUS CONDENS F 30 E
Page 6: ...5 Instructions for Use ...
Page 15: ...14 2 3 Block diagram 34 ...
Page 27: ...26 5 9 Wiring diagram 1 2 3 4 5 6 7 11 9 8 10 12 13 14 15 16 17 18 ...
Page 36: ...Installation and servicing instructions strictly reserved for qualified gas installers 35 ...
Page 50: ...Installation and servicing instructions strictly reserved for qualified gas installers 49 ...
Page 53: ......