![Saunier Duval THEMA F 23 E Installation And Servicing Instructions Download Page 10](http://html1.mh-extra.com/html/saunier-duval/thema-f-23-e/thema-f-23-e_installation-and-servicing-instructions_1202905010.webp)
10
BOILER INSTALLATION
Statutory requirements
The installation of this boiler must be carried out by
a competent person in accordance with the rel-
evant requirements of the current issue of:
The Gas Safety (Installation and Use) Regulations
The Building Regulations
The local water company Byelaws
The Building Standards Regulations (Scotland)
The Health and Safety at Work Act
Sheet metal parts
WARNING. When installing or servicing this boiler,
care should be taken when handling the edges of
sheet metal parts to avoid the possibility of personal
injury.
Ins 020
Ins 021
Installing the boiler
Prior to starting work, the system must be thoroughly
flushed so as to eliminate any foreign bodies and
contaminants such as filings, solder particles, oil,
grease etc.
Note.
Solvent products could cause damage to the
system.
Note.
If using a rear outlet flue system, follow the
instructions in
'Rear outlet flue installation'
section
prior to hanging the boiler.
• Engage boiler upper part onto the hook,
see dia-
gram 9.
• Allow the boiler to seat down onto support plate,
see diagram 10.
• Fit filter and washers, strictly adhering to the se-
quential order and directions shown on
diagram 5.
• Connect the various couplings between the
boiler and the connection plate.
➞
➞
Diagram. 9
Diagram. 10
REAR OUTLET FLUE INSTALLATION
The boiler is supplied for rear outlet flue connec-
tion.
Alternatively, the boiler is designed to allow the flue
system to be connected to the top of the boiler,
top outlet flue connection.
For top outlet flue connection, refer to '
Top outlet
flue installation'
Rear outlet flue - kit 86151
The rear outlet flue system consists of two parts, a
white painted outer pipe and an aluminium inner,
they are positively locked together when assem-
bled.
The flue kit 86151,
see diagram 11
, is 1000 mm long
and comprises:
- Outer pipe ...........................................................
A
- Inner pipe .............................................................
B
- External rubber sealing collar ...........................
C
- Flue elbow ............................................................
D
- Internal flange ......................................................
E
- 'O' rings ..................................................................
F
- Screws ...................................................................
G
- Rubber collar .......................................................
H
- Clamp and seal ....................................................
I
- Gasket ...................................................................
J
A - Direct rear outlet flue
Mark correct position of hole from template using
hole between hook and connecting plate.
Pho 422
Diagram 11
A
B
C
J
H
D
F
E
G
I
Summary of Contents for THEMA F 23 E
Page 28: ...28 108198 B 06 98...