Models           SETTING - OUTPUT        SETTING - OUTPUT       MAX.       

GAS RATES

  

                     

Nat. Gas G20 - Case Off         Nat. Gas G20 - Case On      

CO/CO2

  

Nat. Gas G20

 

 

OUTPUT

          

MIN. 8.3 kW

  

MAX. 28.0kW     MIN. 8.3 kW

  

MAX. 28.0kW  

Ratio

         MAXIMUM

          

Ecosy SB 28E            9.0 - 9.4%CO2                         9.2 - 9.6%CO2             0.004          3.0 m3/h
Ecosy 28E                9.0 - 9.4%CO2                         9.2 - 9.6%CO2             0.004          3.0 m3/h

OUTPUT

          

MIN. 6.8 kW

  

MAX. 24.5kW     MIN. 8.3 kW

  

MAX. 28.0kW   Ratio          MAXIMUM

          

Ecosy SB 24E            9.0 - 9.4%CO2                         9.2 - 9.6%CO2             0.004          2.6 m3/h
Ecosy 24E                9.0 - 9.4%CO2                         9.2 - 9.6%CO2             0.004          2.6 m3/h

Models             SETTING - OUTPUT         SETTING - OUTPUT       MAX.    

                         

Nat. Gas G30 - Case Off         Nat. Gas G30 - Case On      

CO/CO2

 

 

                         

OUTPUT

            

MIN. 9.9 kW

  

MAX. 20.4kW       MIN. 9.9 kW

  

MAX. 20.4kW    

Ratio

   

   

Ecosy SB 24E               10.0 -10.3%CO2                   10.3 - 10.6%CO2                0.004 
Ecosy 24E                    10.0 -10.3%CO2                   10.3 - 10.6%CO2                0.004 

 

Models             SETTING - OUTPUT         SETTING - OUTPUT       MAX.    

                         

Nat. Gas G31 - Case Off         Nat. Gas G31 - Case On      

CO/CO2

 

 

                         

OUTPUT

          

MIN. 11.4 kW

  

MAX. 24.5kW     MIN. 11.4 kW

  

MAX. 25.4kW    

Ratio

   

   

Ecosy SB 24E               11.9 -12.1%CO2                   12.3 - 12.5%CO2                0.004 
Ecosy 24E                    11.9 -12.1%CO2                   12.3 - 12.5%CO2                0.004 

 

Summary of Contents for Ecosy 2 SB 28E

Page 1: ...y SB 28E Ecosy 28E KIT Pt No 05632900 incl 1 off O ring 4 off screws MODEL Ecosy 24E Ecosy SB 24E KIT Pt No 05617100 IMPORTANT NOTE THESE INSTRUCTIONS SUPERCEDE THE GAS VALVE SETTING PROCEDURE CONTAINED WITHIN THE ORIGINAL APPLIANCE LITERATURE ...

Page 2: ...he appliance combustion circuit and relevant seals Electrical gas and water connections System pressure the combustion performance operational gas inlet pressure and gas rates refer to the following procedure ALL MODELS Refer to the installation and servicing instructions supplied with your boiler to fit the replacement gas valve After assembly test for gas soundness and purge in accordance with t...

Page 3: ...standard NOTE Due to the modulating operation of the boiler and the need to check the gas inlet pressure and measure the gas rate at maximum rate it will be necessary to force it to maximum Operational Gas Inlet Pressure With ALL other gas appliances operating check the operational supply pressure at the gas service isolation valve test point refer to your Installation literature supplied with you...

Page 4: ...MUM Ecosy SB 24E 9 0 9 4 CO2 9 2 9 6 CO2 0 004 2 6 m3 h Ecosy 24E 9 0 9 4 CO2 9 2 9 6 CO2 0 004 2 6 m3 h Models SETTING OUTPUT SETTING OUTPUT MAX Nat Gas G30 Case Off Nat Gas G30 Case On CO CO2 OUTPUT MIN 9 9 kW MAX 20 4kW MIN 9 9 kW MAX 20 4kW Ratio Ecosy SB 24E 10 0 10 3 CO2 10 3 10 6 CO2 0 004 Ecosy 24E 10 0 10 3 CO2 10 3 10 6 CO2 0 004 Models SETTING OUTPUT SETTING OUTPUT MAX Nat Gas G31 Case ...