5 Set-up
16
Installation instructions MiLink Plus 0020282112_01
5 Set-up
5.1 Checking the scope of delivery
▶
Check that the scope of delivery is com-
plete and intact.
Num-
ber
Designation
1
Communication unit
1
Wall bracket
1
Bag with bolts and wall plugs
1
Clamping screw
1
Cable
1
Cable bracket
5.2 Checking the assembly and
installation prerequisites
1. Check whether the communication unit
is compatible with the heat generator
and the room thermostat in the installa-
tion. (
2. When choosing the installation site,
pay attention to the dimensions of the
communication unit.
Technical data (
6 Installation
6.1 Qualification
Only qualified electricians may carry out
the electrical installation.
7 Electrical installation
7.1 Connecting to the heat
generator
1. Switch off the power supply of the heat
generator.
2. Consult the boiler's installation instruc-
tions in order to determine the affected
connection terminal X32 and its posi-
tion.
3. Connect the enclosed cable to the heat
generator.
7.2 Connecting to the
communication unit
1. Unclip the unit mounting bracket from
the communication unit.
2. Connect the cable
(1)
to the commu-
nication unit and, in doing so, observe
the colour code on the sticker
(2)
below
the plug connection
(3)
.
–
The colours of the wires must match
the colours on the sticker.
3. Re-establish the power supply of the
heat generator.
7.3 Requirements for the
installation site
,
1. Avoid interference between the com-
munication unit and its environment
(magnetic fields, electrical units, metal
structures, etc.).
2. Determine a location in order to start
the search.
3. To determine the best possible signal
strength for the mobile network, move
the communication unit in order to de-
termine the installation site.
4. Each time you move the communica-
tion unit, wait for 10 seconds in order
to test the signal strength of the mobile
network.
Condition (signal strength of the mo-
bile network/communication with the
server): Meaning of the network LEDs
(
◁
The illuminated LEDs display the
signal strength of the mobile net-
work.
◁
The LEDs automatically switch off
after 30 minutes. The signal strength
of the mobile network is then no
longer updated.
5. Mark the drill holes.
6. Temporarily position the communica-
tion unit close to the selected installa-
tion site.