Gas Range Manual
Page 21
Revision: 24 Feb 2011
CONVERSION INSTRUCTIONS
TO BE COMPLETED BY AN AUTHORISED PERSON
ENSURE GAS IS ISOLATED WHILE PERFORMING
CONVERSION WORK. PERFORM A LEAK TEST BEFORE
IGNITING AND CALIBRATING BURNER AND PILOT
ADJUSTMENTS.
TO PROPANE GAS
Regulator
Change regulator to PROPANE gas configuration
and adjust as necessary
Open Burner/Grill Burner Access and change the injectors to PROPANE Gas
injectors
(refer Nominal Gas Consumption
Table)
Oven Burner
Access and change the injector to a PROPANE
Gas Injector
(refer Nominal Gas Consumption
Table)
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust.
AMEND DATA PLATE AND APPLY ‘PROPANE’ GAS LABEL
TO NATURAL GAS (NG)
Regulator
Change regulator to NG gas configuration and
adjust as necessary
Open Burner/Grill Burner Access and change the injectors to a NG Injectors
(refer Nominal Gas Consumption Table)
Oven Burner
Access and change the injector to a NG Injector
(refer Nominal Gas Consumption Table)