Gas Range Manual
Page 12
Revision: 24 Feb 2011
TEST POINT PRESSURE
The pressure test point is located on the gas manifold. The gas manifold and
pressure test point is accessed by removing the gas valve control knobs and
the front panel. The test point pressure is shown in the Nominal Gas
Consumption Table
.
VENTILATION AND AIR SUPPLY
All gas burners and pilots require sufficient air to operate. For optimum
performance and for your safety, it is ESSENTIAL that the equipment, in the
installed position, has the proper air and ventilation and the correct
exhaust/canopy and air balance. The correct installation and compliance with
all regulatory and other requirements is the responsibility of the
purchaser/owner.
Please note that a strong exhaust canopy will create a vacuum if there is
insufficient replacement air. The amount of air exhausted must be replaced by
an equal amount of air.
Airflow to the appliance must not be blocked or restricted (e.g. large objects
should not be placed in front of the appliance). The flue must never be covered
or restricted in any way.