Page 1: ...ore or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service and maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment Instructions to be followed in the event the user smells gas...

Page 2: ...ion the repair or replacement of any part found by Saturn to be warranted herein Saturn shall bear the normal labor charges for repair or replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United States and dur ing regular straight time hours Travel outside of the 35 miles and any work performe...

Page 3: ... FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediately and file CONCEALED DAMAGE claim with them This should be done within fifteen 15 days from the date the delivery was made to you Be sure to retain the container for inspection Manufactuer cannot as...

Page 4: ...Page 3 FEATURES AND OPERATING CONTROLS FEATURES OPERATING CONTROLS Fig 1 Heavy Duty Gas Griddle Features Operating Controls ...

Page 5: ...ed with the supplied 4 legs properly installed Do not operate this appliance if the smell of gas is present Turn off all gas supply valves and move to a remote location to call your manufacturer for service The technical content of this manual including any parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel only Any procedure which requi...

Page 6: ...or required clearances Maintain required clearances between the appliance and adjacent combustible surfaces The griddle must be installed in an area with sufficient make up air for proper combustion and must be installed such that the flow of combustion and ventilation air will not be obstructed When used with an exhaust fan special precautions must be observed to avoid interference with the opera...

Page 7: ...urners Additionally 1 The gas supply line used to connect the griddle to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be inside 3 4 diameter or greater 3 Use pipe sealant made specifically for gas piping on all pipe joints Apply sealant sparingly to the male threads only Sealant must be resistant to the actio...

Page 8: ... strongly recommended The shut off valve must be installed between the gas supply piping and the gas pressure regulator It is the responsibility of the gas piping installer to identify the code requirement for a shut off valve Shut off valves moisture trap and all associated piping must be supplied by the gas piping installer DANGER FIRE AND EXPLOSION HAZARD NEVER use an open flame to check for ga...

Page 9: ...e front panel and all knobs before returning the unit to service ADJUST BURNER FLAME Remove all burner control knobs then remove the front panel Turn an individual burner on Loosen the locking screw on the shutter Turn the shutter to admit more or less air as required Adjust the air shutter until the flame is mostly blue in color Tighten the locking screw when finished Replace the front panel and ...

Page 10: ...ea for gas Be sure to smell near floor level because some gas is heavier than air and will settle to the floor For initial startup and any time the gas supply has been shut off it may take several minutes to light the pilot while air in the piping and manifolds is purged The pilot light must be lighted by hand Turn all control knobs to the full OFF position The pilot is located adjacent to one leg...

Page 11: ...ntermittent use WARNING FIRE HAZARD NEVER attempt to force or repair a stuck control valve Contact your manufacturer for repairs Forced or improperly repaired valves pose the risk of fire and or explosion WARNING FIRE AND EXPLOSION HAZARD If the pilot light should be extinguished turn off the gas shut off valve and remove the grate and drip pan Allow the appliance to vent for five minutes before a...

Page 12: ...grease trough must be thoroughly cleaned Using a scraper remove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease tray 6 After scraping all cooking waste from grease trough into the grease tray take the grease drawer to the kitchen cleaning area and properly dispose of all waste a Clean drawer with hot water and a mild detergent b Dry drawer tho...

Page 13: ...mpened with clean water Wipe exterior surfaces dry with a soft clean cloth Allow burners to air dry so that interior passages are completely free of water Examine burners to be sure the air shutters are in their proper position Reinstall burners with flame openings up The venturi air shutter slides over the nozzle of the control valve The pegs on the rear of the burner set in corresponding notches...

Page 14: ...ontrol Burner or other internal component Contact manufacturer for repairs Pilot will not light Gas supply off Check main unit gas valves Air in lines Turn pilot valve on Attempt to light pilot every 15 sec Pilot valve not on Turn pilot valve on adjust Burner not hot enough Temperature control not set Adjust for desired temperature Shutter or nozzle out of adjustment Contact qualified technician f...

Page 15: ...RANT _____________________________ LOCATION ___________________________ INSTALLATION DATE ________________________ TECHNICIAN ________________________ SERVICE COMPANY ____________________________________________________________ ADDRESS ___________________________ STATE ______________________ ZIP__________ TELEPHONE NUMBER _____ _____________ ___________________ EQUIPMENT MODEL NO _________________...

Page 16: ...Page 15 ...

Page 17: ...Page 16 ...

Reviews: