5. ELECTRONIC CONTROLLER INSTRUCTION
5-1-1
DIXELL XR60C PARAMETER FOR
PTM23F
NO.
CODE
PARAMETER
SET(
℉
)
1
Set
Main Set point
-7
2
Hy
Differential(hysteresis)
4
3
LS
Lower limit of main set point
-11
4
US
Upper limit of main set point
-1
5
Ot
Offset
-1
6
P2P
Evaporator probe presence
Y
7
OE
Evaporator probe calibration
0.0
8
P3P
Condenser probe presence
Y
9
P3F
Condenser probe function
Au2
10
O3
Condenser probe calibration
0
11
Ods
Outputs delay at start up
0
12
AC
Minimum time interval between the deactivation and
successive activation on compressor
5
13
CCt
Continuous cycle duration
0
14
Con
Compressor on-time during probe failure
10
15
COF
Compressor off-time during probe failure
10
16
CF
Unit of measure
℉
17
rES
Resolution
dE
18
Lod
Probe displayed
P1
19
tdF
Defrost type
EL
20
dtE
Defrost-end temperature
45
21
IdF
Time interval between defrost cycle
6.0
22
MdF
Max defrost cycle time
20
23
dSd
Start defrost delay
0
24
dFd
Displaying during defrost
it
25
dAd
Real temperature display delay at defrost end
0
26
Fdt
Dripping time
2
27
dPo
First defrost cycle after controller start up
n
28
dAF
Defrost delay after fast freezing
0
29
Fnc
Fan operating mode during normal controller
o-n
30
Fnd
Fan activation delay at controller startup and after
defrost
2
31
FSt
Fan stop temperature
54
32
ALC
Temperature alarms configuration
rE
33
ALU
Max temperature alarm differential
90
34
ALL
Minimum temperature alarm differential
0
Summary of Contents for PTM23F