8
4. Please clean the filter before starting the air-conditioner referring to page 6
“Cleaning” for how to operate.
5. Check to see whether the outdoor install bracket is damage. If yes, please contact
our Service centre locally.
¨
Safety tips
1. In order to use the air conditioner properly, please refer to its working temperature
range. Otherwise, indoor unit automatic protection function may be activated, cooling
or heating efficiency will be weakened.
Working temperature range
Cooling
Indoor
Maximum:
Minimum:
DB/WB
DB/WB
32
0
C/23
0
C
21
0
C/15
0
C
Outdoor
Maximum:
Minimum:
DB/WB
DB/WB
49
0
C/27
0
C
21
0
C/15
0
C
Heating
Indoor
Maximum:
Minimum:
DB/WB
DB/WB
27
0
C -
20
0
C -
Outdoor
Maximum:
Minimum
DB/WB
DB/WB
24
0
C/18
0
C
-15
0
C/-16
0
C
Care and Maintenance
¨
Cleaning
Cleaning the indoor unit
1. Turn off the air-conditioner and remove the electrical plug from the outlet.
2. Wipe the indoor unit with dry cloth or wet cloth which is dipped by cold water.
·
Note:
• Don’t use water above 45 to wash the panel, or it could cause deformation or
depigment.
• Don t use thinner, polishing powder, benzene and other volatile chemicals.
• Don t use liquid or corrosive detergent clean the appliance and don t splash water or
other liquid onto it, otherwise, it may damage the plastic components, even cause
electric shock.
Cleaning air filter
1. Raise up the front panel of indoor unit, until it suddenly stops, then raise up the
protruded part of air filter, and then take it out.
2. Use a vacuum cleaner or wash them with water, then dry it in the shade.
9
3. Reinsert the air filter into the indoor unit until being entirely fixed, then close the
front panel.
¨
Maintenance
1. Select “FAN” operation mode, make
the air conditioner run a long time to dry.
2. Turn off the air conditioner and cut off
the power supply.
3. Take out the batteries from the remote
controller.
4. Clean air filters and other parts.
Troubleshooting
Check the following before requesting on service centre if the malfunction occurs.
Phenomenon
Troubleshooting
Air conditioner dose not operate at all.
• Has the power been shut down?
• Is the wiring loose?
• Is the voltage higher than 264V or lower
than 198V?
• Is the fuse burnt?
• Does it reach the set time for start up?
Remote controller is not available.
• Is the remote controller out of effective
distance to the indoor unit?
• Is the battery exhausted?
• Are there any obstructions between the
controller and the signal receptor?
Cooling (heating) efficiency is not good.
• Is the setting temperature suitable?
• Is the air inlet or outlet obstructed?
• Are air filter dirty?
• Is indoor fan speed set at low speed?
• Is there any heat source in your room?
Indoor unit does not operate immediately
when the air conditioner is restarted.
Once the air conditioner is stopped, it will
not operate in approximately 3 minutes to
protect itself.
There is unusual smell blowing from the
outlet after operation is started.
This is caused by the odour in the room
permeated from building material,
furniture, or smoke.
Sound of water flow can be heard during
cooling operation.
This is caused by the refrigerant flowing
inside the unit.
Mist is emitted during cooling operation.
Because the air of the room is cooled
Summary of Contents for CS-09
Page 1: ...HOUSEHOLD SPLIT SYSTEM SERIES INVERTER C INVERTER INVERTER CS 09 CS 12...
Page 7: ...12 RU INVERTER Saturn 1 5 1 5 C WARNING CAUTION 13...
Page 8: ...14 1 2 3 4 5 6 7 50 C 8 15 9 1 2 3 4 5 6 7 8 9 10 11...
Page 9: ...16 1 Auto 2 Auto 1 2 17 1 2 3 4 6 5 1...
Page 11: ...20 3 21 90 110 3 0 10 A 30 A 1 5...
Page 12: ...22 2 3 220 230 50 INVERTER 1 1 1 1 23 U INVERTER Saturn 1 5 1 5 WARNING CAUTION...
Page 13: ...24 25 1 2 3 4 5 6 7 50 C 8...
Page 14: ...26 9 1 2 3 4 5 6 7 8 9 10 11 27 1 Auto 2 Auto 1 2...