Quick Reference 

 

 

 

  

 

 

 

 

 

 

 

Green 

Red 

Connectivity 

Switch 

Comment 

Fast, continuous blinking between green 
and red. 

N/A 

N/A 

When device is in the Factory Reset state 

Four blinks of red, four blinks of green, 
repeating. 

Connected 

N/A 

When device is set to 

Locate 

Mode 

Off 

Off 

Not connected 

Open 

Not Connected, switch open 

Off 

On 

Not connected 

Closed 

Not Connected, switch closed 

Short blink every 4s 

Off 

Connected 

Open 

Connected, switch open 

Short blink every 4s 

On 

Connected 

Closed 

Connected, switch closed 

On (up to 10s) 

Off 

Attempting to connect 

N/A 

While device is attempting to join network 

Fast Blink (3s) 

Off 

Joined or re-joined 
successfully 

N/A 

Indicates successful network join or re-join attempt 

Off 

Fast Blink (3s) 

Failed to join or re-join 

N/A 

Indicates unsuccessful network join or re-join attempt 

Slow blink between green and red at ~1Hz 

Connected 

N/A 

Indicates that the device is being remotely updated 

Feature Name 

Button Action 

Resulting Action 

Association 
Join 

5 second press 
and release 

Device will join any ZigBee HA network with ‘Permit Joining’ mode enabled. When the button is pressed the button 
colour will change to yellow, and then begin to rapidly blink green once is has been held long enough to trigger an 
Association Join.  At this point the button should be released, and the button will shine solid green while it scans for a 
suitable network. The button will then blink green if the join operation is successful, or blink red on failure. 

Factory Reset 

Press and hold 
button for at least 
10 seconds 

Returns the device to its factory reset state. When the button is pressed, the button colour will change to yellow, and 
after 10 seconds the button will begin to rapidly blink red indicating that the device will return to factory reset state. 
The user should wait about 5 seconds before attempting another Association Join following a Factory Reset. 

Manual 
Switch 

Press the button 
briefly (<1 second) 

Manually switches the device relay. Has no effect on non-switching variants of this device. 
 
 

SS9005 Mini Three Phase Meter – Std HA Release 

Button LED Indication Quick Reference 

Button Command Quick Reference 

Note:  The LEDs will automatically dim to one 
third brightness after 15 seconds of inactivity. 

Summary of Contents for SS9005

Page 1: ...D501 2 4 29 Oct 2015 SS9005 Mini Three Phase Meter User Manual Version 1 3 Std HA Release build V003...

Page 2: ...Specifications 6 5 Commissioning and Installation Instructions 7 5 1 Before Installation 7 5 2 Installation 7 5 3 Commissioning 11 6 Switching 12 7 Metering 13 8 Device Clusters and Attributes 14 8 1...

Page 3: ...ent failure This product is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given super...

Page 4: ...join any ZigBee HA network with Permit Joining mode enabled When the button is pressed the button colour will change to yellow and then begin to rapidly blink green once is has been held long enough t...

Page 5: ...005 an ideal choice for monitoring renewable generation sources and energy storage devices Three phase consumption is tracked independently to provide instantaneous three phase power and accurate thre...

Page 6: ...Range 25 C to 80 C Relative Humidity 10 95 non condensing Average Power Consumption 2W Mass 0 103kg Dimensions 60 5 x 90 x 35 5mm Wire gauge 0 1mm2 min 2 5mm2 stranded or 2 5mm2 solid core max IP Rati...

Page 7: ...ini Three Phase Meter is designed to be straightforward to install into a standard domestic or commercial switchboard The following steps should be followed to install the device 1 Identify the circui...

Page 8: ...y an approved circuit breaker The maximum voltage permitted between the Neutral N terminal and any of the phase input terminals A B or C is 240VAC Exceeding this limit may cause permanent damage to th...

Page 9: ...sources and voltages share the same phase Figure 1 Mini Three Phase Meter monitoring a Three Phase load Cable of minimum cross section 0 1mm2 and maximum cross section 1 5mm2 stranded or 2 5mm2 solid...

Page 10: ...ay contactor or control system Refer to the relevant documentation when connecting this Mini Three Phase Meter to a third party control device See Section 6 Switching for more information 6 Apply powe...

Page 11: ...before activating the first device using the Factory Reset LLLSS button sequence 2 Instruct the new Mini Three Phase Meter to join the network by pressing and holding the front panel button for 5 sec...

Page 12: ...l IO on a control device such as a PLC The example below shows a SS9005 Mini Three Phase Meter being used to control an external contactor with a 240V coil by switching the active input to the contact...

Page 13: ...ith the supplied CTs IMPORTANT Attaching a third party CT to the device can damage the device and will void the product warranty SS9005 Mini Three Phase Meter devices have a variant label on the front...

Page 14: ...ver it may not be possible for a device to send 11 attributes in a single report If the total size of the report exceeds the maximum payload size 60 bytes some attributes will be excluded from the rep...

Page 15: ...which can trigger a safe state reversion 1 Loss of ZigBee communications between the meter and the coordinator e g ESBox 2 Receipt of a start revert command from the ZigBee coordinator regularly sent...

Page 16: ...ed by receipt of a stop revert message from the ZigBee coordinator Since stop revert messages will only be received by the device if the ZigBee network is working and the ESBox is able to communicate...

Page 17: ...00 N 57664 e140 Accumulated Energy 1 Active Import Wh 1 N 57665 e141 Accumulated Energy 1 Reactive Import varh 1 N 57721 e179 Accumulated Energy 1 Active Export Wh 1 N 57722 e17a Accumulated Energy 1...

Page 18: ...Current attribute cannot be configured for reporting All SS9005 phases are calibrated for the same CT type The Maximum Current attribute specifies the rating of the supplied current transformers The f...

Page 19: ...ining mode Try to join the device again Saturn South metering devices will initially scan a reduced subset of the full range of available ZigBee channels If the network is on a channel that is not in...

Reviews: