Satron VCT

Calibration guide

Satron Instruments  Oy

PL 22, 33901 Tampere

Puh. 0207 464 800, Telefax 0207 464 801

www.satron.com, [email protected]

BCs221

Rev.1.0

15.5.2013

Satron VCT 

menu structure

the selected unit for 

measurement (%Cs)

the value for the primary 

mA-ouput

the temperature of the 

sensor head (E electronics)

the name of active recipe

the I/O confi guration 

menu

the device information 

menu

the system confi guration 

menu

the mA-output              

confi guration menu

active recipe selection 

menu

restore the water point to 

memory

store a new sample to 

memory

CALIBRATE calibration 

with samples (1/2-point)

CALIBRATION HISTORY

the transmitter calibration  

history

the sample history (10pcs)

the settings for active 

recipe

the transmitter calibration 

in factory units (FU)

the testing of the mA-loop 

(4, 20 selected mA)

the list of accumulated 

errors

the testing of digital in- 

and outputs

the calibration of the 

current loop (mA-out)

the sensor temperature 

sensor calibration

the settings for data-

logging

the diagnostics for current 

and I/O-kommunication

(ei käytössä)

the gain correction for 

calibration 

the off set correction for 

calibration

the water value

the stored sample points 

(1...9)

the list of available sample 

points for 1/2-point 

calibration (samples with 

given laboratory value)

the date/time stamped list 

of calibrations

the list of recipes       

(RECIPE 1...4)

the lower limit for measur-

ing range (4mA)

the upper limit for mea-

suring range (20mA)

the time constant for out-

put averaging (1...50Hz)

the time constant for out-

put damping (0...60s)

the alarm current (3.7mA 

or 22.5mA)

the TAG code for device 

(free-format text)

date / time (dd.mm.yyyy) 

(hh.mm.ss) settings

the display settings (back-

light intensity and angle)

the multidrop- ja burst 

mode settings

the password (0...999) 

protection

restore factory settings

the language selection for 

display 

tempereature unit selec-
tion (Celcius, Farenheit)

the display unit selection

(%Cs, mg/L...)

the name of manufacturer

(SATRON)

the type code of device

the assembly number for 

device

the version for device 

hardware and electronics

the serial number for 

device

the operation time counter

confi guration menu for 

inputs/outputs(I/O 1...3)

the type selection

(in-, output, 2nd mA-out)

the function settings for 

digital in-/output

digitaalisen lähdön off /on 

suunnanvaihdon viive

 the source for digital out-

put to change its state

the delay for digital out to 

change from ON to OFF

the overfeed timer to limit 

continuous ON state

the scource for 2nd 
mA-output (PV, ST, ET..)

the lower range value for 

2nd mA-out (4mA)

the time constant for 2nd 

mA-out damping (0...60s)

interpolation type for mul-

tipoint calib(line, spline)

the number of points for 

multipoint calibration

the recipe name

ENTER:
Press ENTER to move to lower level in a menu or to accept a com-
mand or parameter value.
UP ARROW:
Use the UP arrow key to move up on the current menu level or to 
increase the selected parameter value. 
DOWN ARROW:
Use the DOWN arrow key to move down on the current menu level or 
to decrease the selected parameter value.
ESC:
Press the ESC to move back/higher in menu or cancel current action.

the LED  intensity settings 

(1...100%)

new sample

the confi guration settings 

menu

the measurement  values 

menu

the transmitter diagnostics 

menu

the calibration menu

the upper range value for 

2nd mA-out (20mA)