Thank you for purchasing the Precision type Digital Thermometer Model SK-810PT 

- This  product  is  designed  to  measure  temperature  connecting  with  various  optional  PT  (platinum 

resistance temperature detector) probes. Do not use it for other purposes. 

- Read this manual thoroughly before using the thermometer. Keep the manual in a safe place for future 

references whenever necessary. 

 

 

Warning 

This thermometer is not explosion-proof. Never use it in an atmosphere containing flammable gases.   

 

Beware of explosion! 

There is a risk of explosion. Take extreme care. 

 

 

For any inquiries, contact us or the dealer from which the unit was purchased. 

 

 
            Caution 

Be sure to observe the following precautions in order to use SK-810PT correctly. 

 

- Do not use this unit as a clinical thermometer. 

- This SK-810PT is a precision instrument. Do not drop this unit or apply impact to it. 

- Never disassemble or modify this unit. Doing so may result in failure. 

- Do not use this unit in water. 

- Do not use this unit in a place exposed to direct sunlight or near heating equipment. Doing so may result 

in deformation of the casing or failure. 

- Do  not  use  this  unit  in  an  environment  where  electrical  noise  is  generated.  Doing  so  may  result  in 

unstable display or larger errors. 

- Do not forcibly pull, bend, or bundle the sensor cord. Placing a heavy object on the sensor cord, heating 

or scratching the cord may also damage it. 

- If this unit is not to be used for a long time, always remove the batteries from the unit. Otherwise, the 

batteries may leak fluid, resulting in failure. 

- Do not wash or wipe this unit with alcohol, thinner, or other solvents. Also, do not wash it in water. If the 

unit  becomes  dirty, wipe it  with a  tightly wrung  cloth  that  has  been dipped  in  warm water with neutral 

detergent. 

- Be  sure  to  use  this  unit  within  the  specified measurement  range.  Using  the  unit  outside  the  specified 

measurement range will result in failure or damage.   

- Inside of the connector is not waterproof structure.    Do not use the connector in wet condition. 

- If this unit is left in a car in the hot summer sun, it will become extremely hot and may malfunction. Do not 

leave the unit in such a place. 

**  For repair or calibration, contact us or the dealer from which the unit was purchased. 

Summary of Contents for SK-810PT

Page 1: ...Instruction Manual Precision Digital Thermometer Model SK 810PT O 09...

Page 2: ...t or near heating equipment Doing so may result in deformation of the casing or failure Do not use this unit in an environment where electrical noise is generated Doing so may result in unstable displ...

Page 3: ...ve REL and moving average AVG values are calculated and displayed Hold function It is possible to freeze the display of measured values By using the HOLD function the measured values can be easily rea...

Page 4: ...g displayed MAX Light up while the maximum measured value is being displayed AVG Light up while moving average value is being display or moving average value is being set REL Lights up while relative...

Page 5: ...rtment The screws are integrated into the battery cover Do not forcibly pull them off as this could damage the cover 2 Install the batteries by referring to the polarity markings and provided on the b...

Page 6: ...ove the cover before using the unit 5 3 Connecting the Sensor Probe 1 While the unit is off insert the sensor connector into the unit by aligning the concave part of the sensor connector with the conv...

Page 7: ...lights up to indicate that the measured values are held 2 To cancel press the HOLD ENTER key again The HOLD indicator goes out and the unit returns to the normal temperature measurement mode The HOLD...

Page 8: ...4 REL Function The REL function displays the relative values changes in measured values compared to the current measured value set to 0 00 C Operation procedure 1 Press the REL key during measurement...

Page 9: ...the store where you purchased the product 8 Troubleshooting Problem Possible cause Action The power cannot be turned on The batteries have run out Replace with new batteries Readings are unstable The...

Page 10: ...connected Accessories 4 AAA alkali batteries vinyl cover neck strap The specifications and the appearance subject to change with or without notice 10 Optional Items Products Cat No Descriptions Option...

Page 11: ...pment The case that the products had been purchased in domestic and were sent to overseas by the purchaser is out of warranty Return of items Authorization must be obtained from us before returning it...

Page 12: ...3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 JAPAN TEL 81 0 3 3254 8117 FAX 81 0 3 3254 8123 URL http www sksato co jp english...

Reviews: