7. Functions 

7-1. HOLD Functions

   

Use this function for easier reading if the temperature changes too frequently during measurement. 

  Press the HOLD key once to hold (freeze) the measured value in a measurement. HOLD will show in display 

section and the measure value is being hold,   

  Press the HOLD key again to release the Hold function. HOLD will dis appear and it returns to the normal 

measurement mode. 

 

 

7-2. Auto Power-off Function 

The  power  will  be  turned  off  automatically  if  the  unit  is  not  operated  for  approx.  60  minutes.  This  function 
conserves battery power if you forget to turn the power off. 

 

Turn the power off and keep pressing the POWER key while pressing HOLD key. Then the power is turned 

on and the auto power-off function has been activated and 

  is indicated in the display section. 

NB. Even if the power is turned off, the Auto-power off function is still active. 

 

To release the Auto Power-off Function, keep pressing the POWER key 
while  pressing  HOLD  key  under  the  power  is  turned  off.    Then  the 
power  of  the  unit  turns  on  and  the  Auto  Power-off  Function  has  been 

released.    At that time, 

  mark is not displayed.     

 
 
 

8. Warnings for low battery 

   

 

When the batteries are exhausted, 

  mark will blink. Place the batteries with new ones. 

      Otherwise, measured value may display incorrectly. 

 
 
 

9. Error Message 

If an error occurs, one of the error codes below will be shown on the temperature display section. 

Error code 

Causes 

Remedy 

 

Measured value exceeds 
the Hi or Lo value. 

 
 
 
Bring the value within the measuring range. 

 

Measured value is higher 
than display range 

 

Measured value is lower 
than display range 

 

Internal processing is 
abnormal 

  Remove batteries. Then load batteries again after leave it for 

a while   

  Replace the batteries to new ones 

 

A sensor signal is 
abnormal.     

Turn the power off once.    Connect the probe securely and turn 
the power on. 

 

Probe is not connected or 
probe is failure. 

This error code is displayed when power is turned on without 
connecting the probe. Connect the probe. 
If  the  error  code  is  displayed  although  the  probe  has  been 
connected, stop using it and contact us or the dealer. 

If the problem still persists, please contact us or the store where you purchased this product.

Summary of Contents for SK-270WP-K

Page 1: ...Instruction Manual Waterproof Digital Thermometer Model SK 270WP K S 05 ...

Page 2: ...oing so may result in unstable display or larger errors Do not forcibly pull bend or bundle the sensor cord Placing a heavy object on the sensor cord heating or scratching the cord may also damage it If this unit is not to be used for a long time always remove the batteries from the unit Otherwise the batteries may leak fluid resulting in failure If the unit becomes dirty wipe it with a tightly wr...

Page 3: ...e Operation Measurement can start just after the power is ON without any set up Waterproof function When connecting the main unit and a probe it conforms to Protection level IP67 in JIS C 0920 and can be washed with running water NB This model is not suitable for use under water Impact resistance The outer protection rubber of the case reduces the impact caused by the fall Display of serial number...

Page 4: ...reeze measured value In the setting mode press this key to subtract set value Displays the measured value or error message Shows when Auto power off function is being set HOLD Lights while measured value is being held Low battery mark Blinks when battery power is insufficient Lid of battery compartment Protection rubber Hook for neck strap Display section Key operation section Connecter for probe ...

Page 5: ...atteries could cause an explosion or leakage Do not dispose of used batteries in a fire Doing so could cause the batteries to explode resulting in injuries or burns Keep the batteries out of the reach of children If a child accidentally swallows a battery contact a doctor immediately For environmental protection dispose of used batteries in compliance with local rules and regulations This thermome...

Page 6: ...disconnected when power is turned on error message Er2 will be displayed Factory default setting of the calibration date is When you require us to calibrate or repair the unit the calibration date will be indicated after the calibration or repair is done at our factory 2 Insert the sensing stem into the object to be measured To measure temperature precisely insert the sensing stem to the depth of ...

Page 7: ...d off Then the power of the unit turns on and the Auto Power off Function has been released At that time mark is not displayed 8 Warnings for low battery When the batteries are exhausted mark will blink Place the batteries with new ones Otherwise measured value may display incorrectly 9 Error Message If an error occurs one of the error codes below will be shown on the temperature display section E...

Page 8: ...size alkaline battery x 2 pcs vinyl cover neck strap instruction manual All specifications and appearance subject to change with or without notice for improvement purpose No 8078 42 digital thermometer is without probe type S270WP 01 probe is not attached WARRANTY POLICY Warranty Our products are warranted to be free from defects in materials and workmanship for a period of one year from date of d...