165
10.11 2-D Code
Printer
CL408e/412e
M-8400RVe
CL608e/612e
M-5900RVe
M-10e
M-8485Se/90Se/60Se/59Se
M-84Pro-2/3/6
LC408e/412e
10.11 ESC+2D31 QR Code (Model 1)
ESC+2D31
HEX Code
ESC
2D31
Parameter
<1B>
16
<32>
16
<44>
16
<33>
16
<31>
16
,a,bb,c,d(,ee,ff,gg)
Default Value
NIL
Valid Range &
Terms of
Command
When Power is Switched Off
The set parameter is not maintained
Valid Range within Items
The set parameter becomes invalid
Valid Range between Items
The set parameter becomes invalid
[Function]
Specifying QR Code (Model 1)
[Format] (Setup part)
<2D31>,a, bb, c, d(,ee, ff, gg)
●Parameter
a
[Error Correction Level]
=
L
:
7%
M
:
15%
Q
:
25%
H
:
30%
b
[Size of one side of cell]
=
Valid Range
:
01 to 32 dots
* Recommend to specify more than 2 dots in the 8 dots/mm and 12 dots/mm for scanner readability.
c
[Data setup mode
=
0
:
Manual setup
1
:
Automatic setup
* Note: You need to change the method of specifying print data with this setting.
d
[Concatenation mode]
=
0
:
Normal mode
1
:
Concatenation mode
Following parameter must be specified when specifying 1 (Concatenation mode) in Concatenation mode.
Omit following parameter in normal mode.
e
[Number of partitions of concatenation mode]
=
Valid Range
:
01 to 16
* Number of partitions: Specifying how many QR code are to be concatenated divided by Concatenation
mode.
f
[Sequential number partitioned by concatenation mode]
=
Valid Range
:
01 to 16
* Sequential number: Specifying what number is it of divided QR code.
g
[Concatenation mode parity data]
=
Valid Range
:
00 to FF
* Parity data: Specifying exclusive OR of all the print data in divided QR code with HEX characters.
[Format] (Data part)
Manual setup (Data setup mod)
<DS>k,n~n
* Use when input mode specification is Numeric mode, Alphanumeric mode and Kanji mode.
<DN>mmmm, n~n
* Use when specifying by binary.
Automatic setup (Data setup mode)
<DN>mmmm, n~n
* Change input mode automatically according to input data.
●Parameter
k
[Input mode]
=
1
:
Numeric mode
2
:
Alphanumeric mode
3
:
Kanji mode (Shift JIS Kanji)
* Specify only when specifying Manual setup in Data setting mode.
* There is binary specification other than above, but data specification command is different.
m
[Number of data]
=
Valid Range
:
1 to 486
* Specify when specifying Automatic setup in Data setting mode or specifying binary specification in Manual
setup.
n
[Print data]
=
Data
QR Code (Model 1)