background image

 

 

 

Precautions

 

1.  Handling batteries   

Observe the following to prevent possible accident by batteries.   

  At loading batteries, use two C size batteries and confirm that the polarities (+/-) are correct. 

  Replace the batteries to new ones every year. Be sure to replace all two batteries with new ones of the 

same type. 

  Do not get the batteries charged. 

  Do not dispose of used batteries in a fire   

  For environmental protection, dispose of used batteries in compliance with local rules and regulations. 

NB: When the liquid leaks, immediately wipe or wash out the liquid. 

 

2.  Replacement of cartridge pen

 

1. Pull pen lifting lever toward you until it stops.   
2. To remove the cartridge pen, pull toward the direction of the arrow.   
3. To attach the pen, slide it onto the pen arm until it stops.   

 Do not touch pen tip. If the finger grease adhere, ink will not flow smoothly.   

 Cartridge pen will last about six months in use of 7-day chart, but life   

 

    may be shortened by the conditions of use. 

 

NB: Be sure to use our dedicated cartridge pens. 

 

3.  Installing chart 

Make sure the markings on the chart are aligned where the overlap occurs, and the lower edge of the chart 
is against the bottom lip of the cylinder.   

NB: Be sure to use our dedicated charts. 

 

4.  Carrying instrument

 

Before lifting the instrument with the handle, make sure that it is locked.

 

 
 

 

Installation place

 

 

Do not use in the followings. Use in such environments may causes of error in indication and record.   

  In a place with vibration, shock or inclination.   

  Outdoor use (exception in an instrument screen)

 

  At exhaust port of air conditioner or at a place subject to direct sunlight.   

  In dusty of sooty environments.   

  Use of blocking the ventholes of the acrylic cover.   

  Near splashing water.   

  In corrosive gases. 

 
 

 

Other precautions

 

  Use the instrument within the measuring range.   

  Do not cover the instrument with a vinyl or like for waterproof purpose or etc. If so, correct value will not be 

obtained   

  Do not disassemble the instrument. Doing so may result in failure.   

  Remove the batteries during transportation.

 

 
 

 

Indication adjustment   

Fine adjustment is available, however please avoid using except when necessary as the instrument is calibrated 
at our factory.   
 

Summary of Contents for NSII-TQ

Page 1: ...Instruction Manual No 7230 00 Sigma II Thermograph Model NSII TQ...

Page 2: ...ctly inspected and securely packed at shipment however the indicated value may shift due to excessive shock or vibration during transportation After unpacking place the unit in a stable atmosphere for...

Page 3: ...ng the lever to the direction of center lift it and open the lid for battery 6 Insert two batteries and close the lid 7 Remove chart holder 8 Wind the chart onto cylinder 9 Attach chart holder 10 Moun...

Page 4: ...tos no 7 to 11 When wind the chart onto the cylinder overlap both ends of the chart putting the start side under the other side Be sure to align both ends of the chart at the position of chart holder...

Page 5: ...dicated cartridge pens 3 Installing chart Make sure the markings on the chart are aligned where the overlap occurs and the lower edge of the chart is against the bottom lip of the cylinder NB Be sure...

Page 6: ...e Insert two C size batteries into the battery compartment with the correct polarities Close the lid while pulling the knob outside Top of the recording cylinder Verifying operation Cylinder starts ro...

Page 7: ...are assured We recommend you will use it at a place where air is not circulated so much How to install the induced draft fan for external installation 1 Press the fan so that the fan installation spr...

Page 8: ...of delivery If repair or adjustment is necessary and has not been the result of abuse or misuse within the one year period please return the units on Freight Prepaid basis and correction of the defect...

Reviews: