The LED is also used during configuration of the shock detector (see:
”).
You can enable / disable the LED. When disabled, the LED will not indicate the events
described above, except for the trouble condition.
Enabling the LED with a DIP switch
If you enable the LED with a DIP switch (by setting the switch to LED position), the LED will
indicate events but remote LED enable / disable will be impossible. Disable the LED with the
switch if you want to enable / disable the LED remotely.
Remote LED enable / disable
The LED terminal is provided to allow remote LED enable / disable. When the terminal is
connected to common ground, the LED is enabled. When the terminal is disconnected from
common ground, the LED is disabled.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal an OC type control panel output programmed e.g. as “Zone test status” or “BI
switch”.
3. Electronics board
Do not remove the electronics board from the enclosure to avoid damage to the
components on the board.
potentiometers for configuring the shock detector (see:
“Configuring the shock detector
”).
DIP switches for configuring the detector (see:
“Configuring the detector settings”).
terminals:
SNS
- input for connecting an NC type detector (e.g. magnetic contact) or a flood
probe. Cable length may not exceed 3 m. If no detector or flood probe is
connected to the input, the terminal must be connected to common ground.
LED
- enable / disable the LED indicator.
S
- alarm output (NC relay) used when the two output mode is enabled (see:
”).
NC
- alarm output (NC relay).
TMP
- tamper output (NC).
COM
- common ground.
+12V
- power input.