24
VERSA Plus LTE
SATEL
3. Ask the user to start the S
TART
D
WNL
TEL function (he is supposed to enter the code and
press
, and then press in turn
). The control panel will call the
computer modem number (the number for communication via PSTN communicator).
4. The DLOADX program will receive the call automatically or the program operator must
accept establishing communication (which depends on DLOADX settings).
300 bps transmission via cellular communicator
Control panel settings:
•
program the telephone number of modem connected to computer – the number for modem
communication via the cellular communicator (P
HONE NUMBER FOR
GSM),
•
configure the built-in LTE module (see: “LTE module” p. 53).
DLOADX program settings:
•
configure the modem communication parameters.
1. Click on the
button in DLOADX program main menu. A drop down menu will be
displayed.
2. Click “Modem 300bps”. Window with modem initialization information will be displayed.
3. Ask the user to start the GSM
AUDIO
function (he is supposed to enter the code and press
, and then press in turn
). The control panel will call the
computer modem number (the number for communication via cellular communicator).
4. The DLOADX program will receive the call automatically or the program operator must
accept establishing communication (which depends on DLOADX settings).
3.4.2 Programming over Ethernet
Communication via Ethernet can be established in one of the following methods:
1. Connection initialized from the DLOADX program. The control panel can be programmed
from any location. If communication takes place in a wide area network, the control panel
must have a public IP address.
2. Connection initialized by the control panel. The control panel can be programmed only
from specified location. This method should be used, when the system user does not
want remote programming to take place without his knowledge. If communication takes
place in a wide area network, the computer with DLOADX program must have a public IP
address.
3. Connection initialized by means of SMS. If communication takes place in a wide area
network, the computer with DLOADX program must have a public IP address.
4. Establishing connection via the SATEL server. The control panel can be programmed
from any location. No public IP address is required for the control panel or the computer
with DLOADX program.
Initiating an Ethernet connection from DLOADX program
Control panel settings:
•
enable DLOADX->VERSA-ETHM
CONNECTION
option (see: “Ethernet module (ETHM)”
p. 53),
•
program the number of TCP port which will be used for communication and the data
encryption key (see: “Built-in communication modules (VERSA-ETH)” p. 50),
•
configure the Ethernet module (see: “Ethernet module (ETHM)” s. 53).
DLOADX program settings:
•
program the control panel address,