background image

 

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

PROGRAMMING 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

EN

  

versa_plus_lte_p_en 09/21 

 
 
 

SATEL sp. z o.o. 

ul. Budowlanych 66 • 80-298 

Gdańsk 

• POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

A

lar

m

 C

ontr

ol P

anel

 

VER

SA

 Pl

us LTE

 F

ir

m

w

ar

V

er

s

ion 

1.

10

 

 

 

Summary of Contents for Versa Plus

Page 1: ...PROGRAMMING EN versa_plus_lte_p_en 09 21 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu Alarm Control Panel VERSA Plus LTE Firmware Version 1 10...

Page 2: ...pecifications and software Current information about the changes being introduced is available on our website Please visit us https support satel eu Hereby SATEL sp z o o declares that the radio equip...

Page 3: ...identifiers 18 3 2 2 Modem communication parameters 19 3 2 3 Ethernet cellular data network communication parameters 20 3 3 Local programming 21 3 3 1 Starting local programming 21 3 3 2 Finishing lo...

Page 4: ...one programming 73 9 6 Proximity card arm disarm device 73 10 Timers 75 10 1 Programming the timers 75 10 2 Timer parameters 76 11 Reporting 76 11 1 Configuring the reporting 76 11 2 Reporting paramet...

Page 5: ...b 96 15 VG Soft program and voice module configuring 97 15 1 Description of VG Soft program 97 15 1 1 Buttons 98 15 1 2 Message tree structure 98 15 1 3 Messages tab 98 15 1 4 Macros tab 99 15 1 5 Nam...

Page 6: ...ad in which the service function menu is available while it is flashing on all the other keypads The service mode may also be signaled acoustically after the corresponding option is enabled Additional...

Page 7: ...t a function press the key with number corresponding to the function number and then You can quickly start the selected function by entering at once a sequence of some digits corresponding to the cons...

Page 8: ...he status of all items these can be e g zones outputs options etc press or The numbers around the display allow the items to be identified Use the and keys to move the cursor After hovering the cursor...

Page 9: ...de signal in DTMF mode a b c d other signals generated in DTMF mode Table 2 Special character functions Entering names The characters that can be entered by using the keys are presented in Table 3 Kee...

Page 10: ...items The flashing LED indicates that that the cursor is there Use the and keys to move the cursor Press any number key to change the LED status to turn it ON or OFF The and keys are not used Enterin...

Page 11: ...s 0 LED OFF 1 LED ON 2 3 4 5 6 7 8 9 A B C D E F Table 4 The binary mode of presenting digits and characters Fig 1 Examples of presenting decimal values by means of LEDs in the LED keypad Value 30 030...

Page 12: ...first 6 characters only digits and characters B C D E and F see Table 4 The arrow keys are not used The value entered can only be corrected after restarting the function 2 6 Service mode menu Shown in...

Page 13: ...Hardware 21 1 Kpds exps 211 1 Identificat 212 2 Settings select device 213 3 Wireless dev 213 1 1 New device 213 2 2 Config device 213 3 3 Remove device 213 4 4 Wirelss zones 213 5 5 Synchronize 213 6...

Page 14: ...38 8 Summer time 39 9 Winter time 30 0 Min code len 4 Timers 41 1 Timer 1 name 42 2 Timer 2 name 43 3 Timer 3 name 44 4 Timer 4 name 5 Monitoring 50 0 Stations 51 1 Station 1 511 1 Tel number 512 2 T...

Page 15: ...8 Duress 5419 9 Arming failed 542 2 Partition 2 5421 1 Arm by user 5422 2 Arm other 5423 3 Quick arm 5424 4 Disarm by usr 5425 5 Disarm other 5426 6 Rest by user 5427 7 Restore other 5428 8 Duress 542...

Page 16: ...codes 55 5 Test at 56 6 Test every 57 7 Test armed 6 Messaging 61 1 Zone alarms 62 2 Output trig 63 3 Arming 631 1 Part 1 user 632 2 Part 1 other 633 3 Part 2 user 634 4 Part 2 other 635 5 Arm p1 fail...

Page 17: ...rol panel will remain in the service mode but the service mode menu will not be displayed The function can be useful e g when you have to leave the keypad but you want to prevent unauthorized personne...

Page 18: ...odem remote connection via the modem TCP IP remote connection via the Ethernet cellular data network 3 1 1 Buttons click to open the VERSA Structure window click to open the Global parameters window c...

Page 19: ...on window will not open if the remote connection is established Instead a window with the connection information will open Opening the Configuration window will only be possible after the connection i...

Page 20: ...nd define the rights of users using those access codes File Access setup Program users see Fig 5 3 2 Parameters related to communication between the control panel and DLOADX program 3 2 1 Communicatio...

Page 21: ...l panel 3 2 2 Modem communication parameters Programming the parameters Telephone numbers You can program the telephone numbers DLOADX program Connection settings window the command for opening this w...

Page 22: ...modems and their settings will be written to disk in the modem ini file Baud Rate transmission rate of the serial port It is recommended that the highest rate acceptable by the modem be set only some...

Page 23: ...ters digits letters and special characters used for data encryption during communication between the control panel and the computer with DLOADX program via Ethernet cellular data network ETHM 1 ID ind...

Page 24: ...d from any location 2 Connection initialized from the DLOADX program but the control panel calls back and sets up the connection The control panel can only be programmed from a defined location 3 Conn...

Page 25: ...menu will be displayed 2 Click Modem 300bps Window with modem initialization information will be displayed 3 After modem initialization click on the Connect button Information on connection establish...

Page 26: ...hich depends on DLOADX settings 3 4 2 Programming over Ethernet Communication via Ethernet can be established in one of the following methods 1 Connection initialized from the DLOADX program The contr...

Page 27: ...t which will be used for communication and the data encryption key or select the LAN VERSA ETH parameter set the data programmed in settings of built in communication modules will be used 1 Click on t...

Page 28: ...l inform you about it Communication via the SATEL server Control panel settings enable DLOADX VERSA ETHM CONNECTION and LAN options see Ethernet module ETHM p 53 program the data encryption key see Bu...

Page 29: ...omputer network address 4 When communication is established the DLOADX program will inform you about it Initiating a cellular connection by using SMS message Control panel settings program the address...

Page 30: ...e of communication via the SATEL server enter the MAC address of built in Ethernet module program the data encryption key 1 Click on the button in DLOADX program main menu A drop down menu will be dis...

Page 31: ...lies to the PSTN communicator If enabled voice messaging the voice message is played back 8 first round or 16 next rounds seconds after completion of number dialing the control panel does not check wh...

Page 32: ...learing if the option is enabled clearing the alarm will automatically cancel messaging about this alarm if the user clearing the alarm has the TEL MESS CLEARING right Service message after tamper ala...

Page 33: ...OPT SRVMOD VIA RESET Limit storing Test transm events when the option is enabled if the Test transmission events directly follow one another they are only written to the event log 3 times Information...

Page 34: ...or to the winter time moved back 4 4 Arming Prevent arming if not ready when the option is enabled if the user arm the system by means of keypad or keyfob the control panel checks that there are no ci...

Page 35: ...protected area as well as limiting access to some portion of the premises to selected users You can create 2 partitions 5 1 Configuring the partitions You can configure the partitions as follows DLOA...

Page 36: ...se of the zones for which the value 0 has been individually programmed The delay is programmed in seconds Up to 255 seconds can be programmed If the value 0 is programmed the zone will act as an insta...

Page 37: ...postpone the auto arming Subsequent arming deferments are only possible by using the A ARM DEFER user function CODE 6 SETTINGS 1 A ARM DEFER Timer priority if this option is enabled the timer always...

Page 38: ...each being equal to half the value defined for the resistor R1 In the EOL configuration the resistance value is equal to the sum of values programmed for the resistors R1 and R2 6 3 Configuring the z...

Page 39: ...Y EXIT or 1 ENTRY EXIT FINAL type zone which makes disarming possible before triggering the alarm Up to 255 seconds can be programmed If the value 0 is programmed the ENTRY DELAY programmed for the pa...

Page 40: ...monitoring station upon violation of the 19 TROUBLE type zone You can enter the following values for the corresponding codes of alarm events 1 201 Low water pressure 2 202 Low CO2 3 203 Gate valve se...

Page 41: ...g you can program values from 1 to 8 In the DLOADX program all the required parameters for zones in ROLLER and VIBRATION configuration are programmed in the Sensitivity field Max violation time if the...

Page 42: ...iolation of the zone ends the partition exit delay countdown 17 SHUNT LOCK the zone ends the partition exit delay countdown and depending on the BLOCKS VERIFICATION option will disable verification or...

Page 43: ...learing Autoreset if the option is enabled the alarm counters for zones for which the AUTO RESET 3 or AUTO RESET 1 option is enabled will be automatically reset at midnight violations of these zones w...

Page 44: ...he keybox is open The event code is sent to the monitoring station If this option is disabled an event will be logged informing about zone violation which will not be reported The option is available...

Page 45: ...2 INTERNAL SIREN depends on the global options TAMPER ALARM ALWAYS AUDIBLE and TAMPER ALARM ON INTERNAL SIRENS 3 BURGLARY signals the alarms from 0 to 5 type zones 4 FIRE ALARM signals the fire alarms...

Page 46: ...so be activated by using the OUTPUTS RESET user function 22 ETHM GSM TROUBLE STATUS indicates built in communication modules Ethernet module and LTE module troubles 7 3 Output parameters Fig 10 DLOADX...

Page 47: ...h will activate the output For the 19 TROUBLE STATUS output function these can be the following troubles the number corresponds to the LED number in the LED keypad and to the item number in graphic mo...

Page 48: ...ction alarm outputs the alarm can be cleared by users having access to the selected partition the 1 EXTERNAL SIREN and 2 INTERNAL SIREN outputs with enabled ARM DISARM CLEAR SIGN option the output wil...

Page 49: ...Fire alarms sign option for the 1 EXTERNAL SIREN and 2 INTERNAL SIREN outputs The output signals in pulsating mode the fire alarms from selected zones see ACTIVATION ZONES and partitions see ALARM SIG...

Page 50: ...ear sign 1 2 Timer 2 15 7 Part 1 alarms Alarm signaling part 1 1 10 Timer 3 15 8 Part 2 alarms Alarm signaling part 2 1 10 Timer 4 15 9 31 TMP zone Mainboard TMP input 1 2 10 Table 7 The way of presen...

Page 51: ...ts default name is VERSA ETH this name can be changed You can connect to the control panel communication bus additional devices keypads expanders other modules which will be needed in the alarm system...

Page 52: ...e control panel it must be a public address You can enter either the IP address or the domain name Port number of the TCP port used for communication between control panel and a computer with DLOADX p...

Page 53: ...r communication via the SATEL server the ports of 1024 65535 range are used as outgoing ports These ports must not be blocked GSM SATEL server GSM if this option is enabled the control panel connects...

Page 54: ...the control panel IP information on the module local public address QR code pressing the button will display the QR code window The window shows the QR code containing information required when config...

Page 55: ...he other devices in the local network can communicate with devices in other networks Obtain DNS server address automatically DHCP DNS if this option is enabled the DNS server IP address is downloaded...

Page 56: ...og into the available cellular network AUTO if this option is enabled and the module cannot log into the network of cellular operator defined by means of the MCC MNC code it will log into the availabl...

Page 57: ...EPHONE NUMBERS table Fig 15 DLOADX program phone call settings Telephone numbers The table presents 1 8 telephone numbers from which it is possible to control the alarm system by means of SMS messages...

Page 58: ...ar network operator 9 3 Keypad 9 3 1 Parameters and options Fig 16 DLOADX program configuring the keypad Descriptions displayed on LCD keypad are shown in square brackets CHIME signal of zones Zone ch...

Page 59: ...by means of the key the key is to be pressed for about 3 seconds Quick control if this option is enabled the users can control the outputs by using the number keys The 15 CONTROLLED outputs must be a...

Page 60: ...e display of LCD keypad The messages will not be displayed if the GRADE 2 global option is enabled 9 3 2 Volume The volume level for different events is configurable in the case of VERSA LCDM VERSA LC...

Page 61: ...CARD READ option you can permit the users to toggle the 15 CONTROLLED type outputs the output status will change after the card is brought close to the keys and held still for about 3 seconds Select t...

Page 62: ...e sensitivity of detection of radio communication jamming is boosted Fig 19 DLOADX program configuring the ABAX 2 wireless system controller and ABAX 2 wireless devices User can replace VERSA LCDM WRL...

Page 63: ...mode remotely is not possible 9 4 3 Settings of ABAX 2 ABAX system wireless devices The wireless keypads constitute a special category of wireless devices for which a separate group of positions is r...

Page 64: ...sor sensitivity of the microwave sensor AOD 200 AOD 210 wireless outdoor dual technology motion detector You can configure sensitivity of the PIR sensor sensitivity of the microwave sensor sensitivity...

Page 65: ...50 Entering 0 disables the check for device presence in the system In the case of the AMD 103 magnetic contact and ASP 100 siren the presence check is performed in a different way than for the other A...

Page 66: ...ne which of the two reed switches is to be active In the case of the AMD 202 detector do not configure Roller shutter input enter 2 digits 1st digit number of pulses from 1 to 8 2nd digit pulse validi...

Page 67: ...not configure Shock detector enter 2 digits 1st digit sensitivity from 1 to 8 1 minimum 8 maximum 2nd digit number of shocks from 0 to 7 For the value 0 shocks are not counted In the case of the AVD...

Page 68: ...fine the rules of device presence control and then press 2 Press any number key to define whether the detector is to be always active no yes and then press 3 Depending on the detector AMD 100 AMD 101...

Page 69: ...es of device presence control and then press 2 Press any number key to define whether the detector is to be always active no yes and then press 3 Enter a digit from the 1 to 3 range to define sensitiv...

Page 70: ...ules of device presence control and then press 2 Press any number key to define whether the detector is to be always active no yes and then press 3 Depending on the detector AVD 100 use the and keys t...

Page 71: ...be enabled no yes and then press ASW 100 ASW 200 1 Enter a number from the 0 to 50 range to define the rules of device presence control and then press 2 Use the and keys to define the way of control i...

Page 72: ...ling the second the optical signaling The method of powering the siren enables it to receive transmissions from the controller at any time Therefore the commands to start stop signaling are sent to th...

Page 73: ...eep in mind that sensitivity of the expander zones may be different from that programmed in the control panel from 20 ms to 140 ms the same as the value programmed in the control panel above 140 ms on...

Page 74: ...erating modes 1 and 2 the relay controlling the 230 VAC circuit is turned on operating mode 0 the plug button is pressed the controller input is activated Select the appropriate zone type 9 5 MICRA wi...

Page 75: ...r is assigned is activated when the detector reports alarm select the appropriate zone type If a detector tamper is to trigger the tamper alarm program the zone as 2EOL NC or 2EOL NO The detector oper...

Page 76: ...ptions Alarm signal Timed alarm sign if the option is enabled the device is audibly signaling alarms during the KEYPAD S ALARM TIME until canceled Alm until clear if the option is enabled the device i...

Page 77: ...timers 10 1 Programming the timers You can program timers DLOADX program VERSA Timers window Fig 22 Fig 22 DLOADX program VERSA Timers window keypad functions available in the service menu TIMERS subm...

Page 78: ...thernet module cellular data network built in LTE module SMS messages control panel gets no acknowledgement of event code receipt built in LTE module GSM voice channel the use of this transmission pat...

Page 79: ...in which event codes are sent to the monitoring station In the TELIM format events can only be sent via the analog telephone line Telephone Telephone no telephone number of the monitoring station for...

Page 80: ...ers troubles identifier 2 alarms triggered from keypad arming disarming by means of zones quick arming loss of communication with wireless devices as well as expander troubles and tampers identifier 3...

Page 81: ...onger for handshake from the monitoring station in case of sending events in the Ademco Express Contact ID or SIA format Enable this option in the event of telephone reporting if the monitoring statio...

Page 82: ...ng station will terminate the procedure except for the test transmissions The following transmission paths are available ETHM Ethernet Ethernet module GPRS SIM1 cellular data network SIM1 card LTE mod...

Page 83: ...rmat for reporting by means of SMS messages It must be defined as required by the monitoring station The SMS message format preset by default in the control panel corresponds to the default settings o...

Page 84: ...ted to the monitoring station if the defined events occur An event code consists of 2 hexadecimal characters digits or letters from A to F The reported events are those for which a code different from...

Page 85: ...for events which are to be reported 8 Define priority of the transmission paths to be used by the control panel 11 6 1 Reporting via analog telephone line 1 Enable the REPORTING TELEPHONE option see G...

Page 86: ...NCRYPT DATA SIA IP KEY HEX SIA IP ACCT and SUPERVISION INTERVAL 5 Specify whether TCP or UDP protocol is to be used 6 Configure the built in LTE module enable the SIM1 option and or SIM2 option enter...

Page 87: ...the selected telephone number about the event You can program from 1 to 7 Retries no for one round the number of attempts made by the control panel to get through during one round You can program fro...

Page 88: ...e numbered from 1 to 64 The voice messages are numbered from 0 to 15 The same voice message can be assigned to several text messages For PAGER messaging define the pager identification parameters 12 1...

Page 89: ...fter going off hook or 8 16 seconds after the dialing is completed NO ANSWER TONE TEST Voice messaging via cellular network 1 Enable the GSM option for the telephone number to be notified 2 Enable the...

Page 90: ...ail address to which messages are to be sent for notification of events Because the message is sent to many recipients the addressees are hidden If you want the addressee to be shown place before the...

Page 91: ...address Fig 28 DLOADX program entering the data of e mail account that will be used for e mail messaging The presented settings are just an example 12 2 3 Starting the e mail messaging 1 Enter the e m...

Page 92: ...after clicking on the button in the DLOADX program main menu 12 3 2 Parameters and options of the SMS messaging SMS messaging if the option is enabled the control panel can notify of occurrence of spe...

Page 93: ...em can be controlled by means of SMS messages containing appropriate control commands The SMS messages should be sent to the number of the currently used SIM card You can program 16 control commands S...

Page 94: ...schedule defines the user rights When adding or editing a user one of the user schedules is selected The default settings of keyfob are tied to the user schedule If a keyfob is assigned to the user th...

Page 95: ...the INHIBIT function CODE 4 BYPASSES 1 INHIBIT Zone isolation using the ISOLATE function CODE 4 BYPASSES 1 ISOLATE the user having additionally the ZONE INHIBITION right can isolate the system zones...

Page 96: ...the monitoring station The alarm will be triggered in the partition in which alarm would be triggered in the event of tamper of the keypad proximity card arm disarm device used for arming disarming o...

Page 97: ...armed mode 38 Disarming clearing alarm in partition 2 39 Arming partitions 1 and 2 full armed mode 40 Arming partitions 1 and 2 night armed mode 41 Arming partitions 1 and 2 day armed mode 42 Disarmin...

Page 98: ...which makes programming easier use the and keys to scroll through the list in the keypad In the LED keypad the number is presented in binary format on LEDs 1 12 in a similar way as the decimal values...

Page 99: ...in day mode 23 Partition 1 Alarm LED is ON when there is alarm in partition 1 24 Partition 2 Alarm LED is ON when there is alarm in partition 2 25 Partition 1 or 2 Alarm LED is ON when there is alarm...

Page 100: ...tification message inactive applies to macro command names message must be synthesized default message applies to names message is synthesized Click on the message to display respective information in...

Page 101: ...language and yyyy is voice test click to open the window in which you can test the selected software voice synthesizer Synthesize missing click to synthesize the missing messages Synthesize all click...

Page 102: ...are to be disarmed after running the macro Arm full click on the button to select the partitions which are to be fully armed after running the macro Arm night click on the button to select the partit...

Page 103: ...by the VG SOFT program identifier of the data file assigned by the VG SOFT program 15 2 Running the VG Soft program for the first time 1 Connect the USB port of control panel to the computer port 2 S...

Page 104: ...suitable auto arming delay in partitions so that the system users can be warned of the automatic arming program the entry delay to be no longer than 45 seconds enable the AUTO RESET 3 option for all b...

Page 105: ...update LAN if this option is enabled communication with the UPSERV update server will take place via the Ethernet module GSM if this option is enabled communication with the UPSERV update server will...

Page 106: ...ust be different from that of the other control commands preprogrammed in the control panel SMS messages The control panel sends out an SMS notification on how the firmware update has proceeded The no...

Page 107: ...ge containing the control command to initiate the control panel firmware update 4 Completion of the control panel firmware update will be indicated by the control panel with an SMS message 18 Manual u...