Satel SATELLINE-3AS/TC User Manual Download Page 10

ANNEX to SATELLINE-3AS User Guide 

SATELLINE-3AS/TC 

02.12.2004 (v.1.0) 

 

  

Page 10 of 11 

SATEL Oy, P.O.Box 142, FIN-24101 Salo, Finland 
Street: Meriniitynkatu 17, FIN-24100 Salo, Finland 

Tel: +358 2 777 7800, Fax: +358 2 777 7810, E-mail: 

[email protected]

 

www.satel.fi

 

4 HEADER INTERFACE 

4.1 Header Connector

 

  

  

SATELLINE-3AS/TC - HEADER CONNECTOR PINOUT  

Type of the connector: 32-pin male Eurocard connector, type B   

  

  

  

Pin#  Signal Name  In/Out 

Level 

Description 

  

  

A1 

GND 

GND 

  

  

  

A3 

PWR_ON 

In 

0..+14VDC 

Radio modem On/Off control                                                                    
( OFF = 0...+0.7VDC, ON = higher than +2.0VDC). 

  

 

A6 

PROG 

In 

0..+14VDC 

Must be normally UNCONNECTED or higher than +3.0 VDC 

Connect to ground in order to:  a) access the setup menu 
                                                  b) update the program flash 

 

  

A14 

PWR_LED 

Out 

High Z / +5V 

POWER LED anode 

  

  

A15 

RD_LED 

Out 

High Z / +5V 

RD LED anode 

  

  

A17 

GND 

GND 

  

  

  

A23 

PWR_IN 

In 

+ 6.0..14VDC 

Power Supply 

  

  

A24 

PWR_IN 

In 

+ 6.0..14VDC 

Power Supply 

  

 

A25 

FLASH 

In 

0..+14VDC 

Must be normally UNCONNECTED. Connected to PWR_IN in order to 
enter the FLASH bootmode programming. 

 

 

A31 

RSSI 

Out 

0..+4.5VDC 

RSSI analog output (option) 

 

  

B1 

GND 

GND 

  

  

  

B3 

TX_A 

In 

RS-232 

Data FROM terminal unit TO radio modem Port 1 

  

  

B5 

RTS_A 

In 

RS-232 

Request To Send FROM terminal unit. Radio modem ignores this. 

  

  

B8 

RX_A 

Out 

RS-232 

Data TO terminal unit FROM radiomodem Port 1 

  

  

B9 

CTS_A 

Out 

RS-232 

Clear To Send. This signal indicates that radiomodem is ready to receive 
data FROM terminal unit. 

  

 

B11 

TX_B 

In 

RS-232 

Data FROM Hiper TO radio modem Port 2 

 

 

B13 

RTS_B 

In 

RS-232 

Request To Send FROM terminal unit. Radio modem ignores this. 

 

 

B16 

RX_B 

Out 

RS-232 

Data TO terminal unit FROM radio modem Port 2 

 

 

B17 

CTS_B 

Out 

RS-232 

Clear To Send. This signal indicates that radiomodem is ready to receive 
data FROM terminal unit. 

 

  

B24 

GND 

GND 

  

  

A1

B1

A32

B32

 

     

Outside view of the header connector. 

 

Summary of Contents for SATELLINE-3AS/TC

Page 1: ...User Guide Version 1 0 SATELLINE 3AS TC Radio Data Modem Module as an Annex to SATELLINE 3AS User Guide version 2 5...

Page 2: ...other than those specifically reserved and intended for use without a specific permit SATELLINE 3AS TC is allowed to be used in the following countries either on licence free channels or on channels...

Page 3: ...ce with the applicable essential requirements Article 3 2 and other relevant provisions of Directive 1999 5 EC Therefore the equipment is labelled with the following CE marking The notification sign i...

Page 4: ...00 Fax 358 2 777 7810 E mail info satel fi www satel fi TABLE OF CONTENTS IMPORTANT NOTICE 1 RESTRICTIONS ON USE 2 PRODUCT CONFORMITY 3 TABLE OF CONTENTS 4 1 INTRODUCTION 5 2 TECHNICAL SPECIFICATIONS...

Page 5: ...s has been implemented to the modem controller software for full control of the features of SATELLINE 3AS TC in integrated use The implementation of SATELLINE 3AS TC is based on the widely used SATELL...

Page 6: ...ious Radiations according to EN 300 113 RADIO RECEIVER Sensitivity 116 110 dBm BER 10 E 3 depending on Receiver settings Common Channel Rejection 12 dB Adjacent Channel Selectivity 60 dB 12 5 kHz 70 d...

Page 7: ...tors The operation of the LED indicators is different in the normal mode and in the FCS Free Channel Scan mode The operation is specified by the two tables below 3 1 1 SATELLINE 3AS TC LED INDICATORS...

Page 8: ...ingle Channel D Dual Channel R Reverse Dual Channel Note Use this command only if the setup of the frequency bands matches the Dual Channel operation SL D Request the operational mode of the radio The...

Page 9: ...signal to be received Signal Treshold level where xxx is a decimal value of the new intended level in dBm SL T Request of the current Signal Treshold Level Response is xxx dBm FCS related Effect and...

Page 10: ...GND A23 PWR_IN In 6 0 14VDC Power Supply A24 PWR_IN In 6 0 14VDC Power Supply A25 FLASH In 0 14VDC Must be normally UNCONNECTED Connected to PWR_IN in order to enter the FLASH bootmode programming A31...

Page 11: ...01 Salo Finland Street Meriniitynkatu 17 FIN 24100 Salo Finland Tel 358 2 777 7800 Fax 358 2 777 7810 E mail info satel fi www satel fi 5 RF INTERFACE 5 1 Antenna connector The antenna connector is a...

Reviews: