background image

2 K-1 

2E 

 K-2 2E 

 K-3 2E 

SATEL 

The K-2 2E and K-3 2E magnetic contacts are designed for flush mounting in wood or plastic. Place 
the contact and magnet facing each other (Fig. 5 – as shown by the example of S-3). To make holes 
for the magnetic contact elements, use a ø9 mm drill. Press the K-2 2E magnetic contact elements or 
screw the K-3 2E magnetic contact elements into the holes made. 

Notes: 

 

Do not use a hammer to drive the contact into the hole (it may damage the reed switch). 

 

When screwing the K-3 2E contact into the hole, the wires become twisted. To prevent them from 
damage, twist the wires against the direction of screwing before installation. 

 

 magnet. 
 contact. 

A – make distance. 
B  –  permissible offset between contact and magnet axes: K-2 2E = 10 mm, K-3 2E = 12 mm. 
C  –  minimum thickness of the wall in which magnetic contact elements can be mounted: 10 mm. 

3.  Specifications 

Magnetic contact type............................................................................................................... 2EOL/NC 
EOL resistors........................................................................................................................... 2 x 1.1 k

 

Maximum switching voltage.............................................................................................................. 20 V 
Maximum switching current ........................................................................................................... 20 mA 
Contact resistance.......................................................................................................................150 m

 

Minimum life expectancy (20 V, 20 mA) ......................................................................................360 000 
Contact material ...............................................................................................................Ru (ruthenium) 
Make distance 

K-1 2E...........................................................18 mm 

 

K-2 2E...........................................................28 mm 

 

K-3 2E...........................................................15 mm 

Break distance 

K-1 2E...........................................................28 mm 

 

K-2 2E...........................................................40 mm 

 

K-3 2E...........................................................24 mm 

Environmental class according to EN50130-5........................................................................................II 
Operating temperature range ............................................................................................ -10°C...+55°C 
Maximum humidity........................................................................................................................ 93±3% 
Weight 

K-1 2E...............................................................10 g 

 

K-2 2E...............................................................10 g 

 

K-3 2E...............................................................24 g 

 

The declaration of conformity may be consulted at www.satel.eu/ce 

 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gda

ń

sk • POLAND 

tel. +48 58 320 94 00 

www.satel.eu 