background image

IVORY 

SATEL 

3.  Electronics board 

 

fixing pins for terminal block.  Description of 
terminals: 

NC

 

-  alarm output (NC relay). 

TMP

  -  tamper output (NC). 

COM

  -  common ground. 

12V

 

-  power input. 

LED

  -  remote LED control. 

MEM

  -  alarm memory control. 

  configuration pins for detector outputs: 

the built-in resistors are to be used –  place the 

jumpers as shown in Fig. 2 (connect the outputs 
as shown in Fig. 10), 

the built-in resistors are not to be used – place the 

jumpers as shown in Fig. 3 (connect the outputs 
as shown in Fig. 9). 

  red color LED to indicate: 

alarm – ON for 2 seconds, 
alarm memory – blinking rapidly, 
trouble – ON, 
warm-up – blinking slowly. 

  potentiometer for sensitivity adjustment. 

 

LED  enable/disable  pins. If the LED is to be enabled, place the jumper as shown in Fig. 4 
(the remote LED enable/disable is not available then). 

  dual element pyrosensor. 

Do not touch the pyroelectric sensor, so as not to soil it.

 

 

4.  Installation 

Disconnect power before making any electrical connections. 

The mirror requires no cleaning. The sealed structure of the optical chamber is 
dustproof. Removal of the electronics board or the mirror is not recommended. 

1.  Remove the front cover (Fig. 5). 
2.  Make the openings for screws and cable in the enclosure base. 
3.  Run the cable through the cable opening, and if the detector is to be mounted on a bracket, 

also through the bracket (Fig. 6). 

4.  Fix the enclosure base to the wall or to the bracket (Fig. 7). 

Reviews: