SATEL
INTEGRA 128-WRL
3
1. General
This manual applies to the INTEGRA 128-WRL control panel. The manual also describes
keypads compatible with the control panel and other devices that may be included in the
security alarm system.
The INTEGRA 128-WRL control panels meet the requirements of the following standards:
– EN 50131-1 Grade 2,
– EN 50131-3 Grade 2,
– EN 50131-6 Grade 2,
– EN 50130-4,
– EN 50130-5 Class II.
2. Features
System structure
•
32 partitions.
•
8 objects (subsystems).
Zones
•
8 programmable hardwired zones on the control panel mainboard:
– support for NO and NC type detectors, as well as roller shutter and shock detectors,
– support for Single EOL and Double EOL configuration,
– programmable value of end-of-line resistors,
– several dozen zone types.
•
Maximum number of programmable zones: 128.
Outputs
•
8 programmable hardwired outputs on the control panel mainboard:
– 2 high-current outputs,
– 6 low-current outputs, OC type,
– over 100 functions,
– execution of custom control functions due to the possibility of programming complex
logic operations on the outputs.
•
Maximum number of programmable outputs: 128.
•
3 high-current outputs on the control panel mainboard with power supply output
functionality.
Communication buses
•
Keypad bus for connecting up to 8 devices.
•
Expander bus for connecting up to 32 devices.
Wireless devices
•
Integrated wireless interface of the ABAX system to allow operation of:
– up to 48 ABAX 2 / ABAX wireless devices,
– up to 248 APT-200 / APT-100 keyfobs.
•
Two-way encrypted radio communication in the 868 MHz frequency band
Communication
•
GSM/GPRS communicator to allow:
– events reporting,