Satel INT-S-BL Manual Download Page 7

INT-S-GR / INT-S-BL 

SATEL 

 

7

Permanent

 - keypad backlighting is permanently "ON". 

No auto-reset after 3 tampers

 - each expander automatically disables the tamper alarming 

in the given expander after three consecutive (not cleared) tamper alarms. This 
prevents multiple recording of the same events in the control panel memory. The option 
allows this feature to be disabled. 

5. Technical Data 

Nominal supply voltage (±15%) .....................................................................................12V DC 
Maximum current consumption.........................................................................................66mA  
Average current consumption ...........................................................................................24mA 
Maximum voltage switched over by relay ............................................................................24V 
Maximum current switched over by relay...............................................................................2A 
Dimensions (length x height x width) ..................................................................80x127x24mm 

 

Summary of Contents for INT-S-BL

Page 1: ...temporary automatically activated mode backlight and LED indicators LED designation ALARM red color steady light indicates an alarm in the keypad controlled partition while blinking indicates that an...

Page 2: ...eypad 3 tamper contact The spring should be pressed against the wall 4 buzzer Figure 2 Schematic view of the keypad electronics board 2 Installation and Connection of the Module Note Prior to hookup o...

Page 3: ...ol sensor to the IN and COM terminals 8 If the keypad is to serve as a code lock connect the wires to control the electromagnetic door lock or another device to the NO terminals 9 Close the casing 3 S...

Page 4: ...nt of the keypad to a partition selected from the list Lock feature the option available in the LCD keypad its activation provides access to the Lock submenu Lock DLOADX Lock feature DLOAD64 its activ...

Page 5: ...y contacts NO the NO contacts are normally open they close on activating the relay during its active state NC the N contacts are normally closed they open on activating the relay during its active sta...

Page 6: ...ling the countdown of the auto arming delay in the partition it has been assigned to Access code signaling hardware enabling this option will activate the signaling of code entry acknowledgement which...

Page 7: ...ive not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 5 Technical Data Nominal supply voltage 15 1...

Page 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...