Satel INT-S-BL Manual Download Page 5

INT-S-GR / INT-S-BL 

SATEL 

 

5

Lock feature 

(DLOADX) / 

Lock 

(DLOAD64)

 

ON if partition armed

 - selecting this option sets the bistable operating mode of the relay 

(i.e. it is active when the partition is armed and normal when the partition is disarmed). 

Note: 

When operating in this mode the relay will change its state automatically, if the 
partition is disarmed from the given keypad. When the partition is disarmed from 
another keypad, the state of the relay will change on entering the CODE and pressing 
the [*] key on the given partition keypad. 

Fixed ON time 

[ON time]

 

- this option sets the monostable operating mode of the relay. 

When the door opening function is called by the user ([CODE] [*]), the relay gets 

activated for the time period entered in the „

Relay ON time

”, and then returns to its 

normal state. 

Fixed ON time - OFF if door open

 [ON, open

Æ

off] - the relay is active until the door is 

opened (the IN input disconnected from common ground), but not longer than for the 
„relay ON time”. 

Fixed ON time - OFF if door closed

 [ON, close

Æ

off] - the relay is active during the time 

when the door is open (the IN input cut off from the common ground) and deactivates 
on closing the door (reconnection of the IN input to common ground), but not longer 
than for the „relay ON time”. 

Relay ON time

 – the time period during which the relay is active. Duration of the „relay ON 

time” can be from 

1

 to 

255

 seconds. 

Relay 

- this option defines the operating mode of the relay contacts: 

NO

 - the NO contacts are normally open, they close on activating the relay (during its 

active state), 

NC

 - the N

С

 contacts are normally closed, they open on activating the relay (during its 

active state).

 

Authorization

 

control

 

[Unauth. event] – opening the door without entering a password from 

the keypad (e.g. with the key) will generate an „Unauthorized door opening” event, it 
can also be signaled on the output type 93 (U

NAUTHORIZED ACCESS

). 

Alarm on unauth. access 

[Unauth. alarm]

 

– when the partition to which the module is 

assigned is armed, unauthorized opening of the door will trigger the alarm and can be 
additionally signaled on the output type 94 (A

LARM

 – U

NAUTHORIZED ACCESS

). 

Max. door open time

 - this option defines the time after expiry of which the module will 

report the „Long opened door” event to the control panel and activate the audible alarm. 
The duration can be set from 

0

 to 

255

 seconds. 

Dependent on door 1 

(or 

Dependent on door 2

)

 

- this function provides a list to choose the 

door which must be closed for the lock to operate. Monitoring of the door state is 
effected through the IN input in the partition keypad, code lock or CA-64 SR expander of 
proximity card readers, or through the zone type 57 (

TECHNICAL 

-

 

D

OOR OPEN

). Two 

dependent doors can be selected. The function allows to create a „sluice” type passage. 

Master users / Users

 - this function defines master users / users authorized to use the given 

keypad. 

Alarms

 

FIRE alarm 

- holding down the     key will trigger the fire alarm. 

AUX. alarm 

[Medical alarm]

 

- holding down the      key will trigger the auxiliary alarm. 

PANIC alarm

 - holding down the     key will trigger the PANIC alarm. 

Summary of Contents for INT-S-BL

Page 1: ...temporary automatically activated mode backlight and LED indicators LED designation ALARM red color steady light indicates an alarm in the keypad controlled partition while blinking indicates that an...

Page 2: ...eypad 3 tamper contact The spring should be pressed against the wall 4 buzzer Figure 2 Schematic view of the keypad electronics board 2 Installation and Connection of the Module Note Prior to hookup o...

Page 3: ...ol sensor to the IN and COM terminals 8 If the keypad is to serve as a code lock connect the wires to control the electromagnetic door lock or another device to the NO terminals 9 Close the casing 3 S...

Page 4: ...nt of the keypad to a partition selected from the list Lock feature the option available in the LCD keypad its activation provides access to the Lock submenu Lock DLOADX Lock feature DLOAD64 its activ...

Page 5: ...y contacts NO the NO contacts are normally open they close on activating the relay during its active state NC the N contacts are normally closed they open on activating the relay during its active sta...

Page 6: ...ling the countdown of the auto arming delay in the partition it has been assigned to Access code signaling hardware enabling this option will activate the signaling of code entry acknowledgement which...

Page 7: ...ive not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 5 Technical Data Nominal supply voltage 15 1...

Page 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Reviews: