10 INT-KWRL2
SATEL
Alarm messages
Partitions
[Part.al.msg.] – if this option is enabled, messages on partition alarms are
displayed (they contain the name of partition).
Zones
[Zone al.msg.] – if this option is enabled, messages on alarms from zones are
displayed (they contain the name of zone). The zone alarm messages have the priority.
Alarms
FIRE
[Fire alarm] – if this option is enabled, pressing the
key for approx. 3 seconds
will trigger the fire alarm.
PANIC
[Panic alarm] – if this option is enabled, pressing the
key for approx. 3
seconds will trigger the panic alarm.
AUX.
[Medical alarm] – if this option is enabled, pressing the
key for approx. 3
seconds will trigger the medical alarm.
3 wrong codes
[3 wrong codes] – if this option is enabled, entering incorrect code three
times will trigger the alarm.
Additional options
Silent PANIC alarm
[Silent panic] – if this option is enabled, the panic alarm triggered from
the keypad will be a silent one, i.e. the keypad will not indicate it, there will be no audible
signal, but the alarm will be reported to the monitoring station. The silent panic alarm is
useful when the control panel is sending events to the monitoring station, but unauthorized
persons should not be aware of the alarm being triggered.
Sign. alarms
[Alarm signal.] – if this option is enabled, the keypad will signal the alarms
audibly.
Key sounds
[Key sound] – if this option is enabled, pressing the keypad keys is confirmed
by beeps.
Sign. trbl. in part. arm
[Trbl.in p.arm.] – if this option is enabled, the
LED goes off after
all managed by keypad partitions are armed (if the option is disabled, the LED goes off
after just one of the partitions is armed).
Sign. new trouble
[New trbl.sign.] – if this option is enabled, the keypad can audibly signal
the occurrence of a new trouble (if the “Trouble memory until review” option is enabled).
New trouble signaling is cleared after the troubles have been reviewed by the user.
Show code entering
[Show code ent.] – if this option is enabled, entering the code is
presented on the keypad display by asterisks.
Show keypad name
[Name (2nd row)] – if this option is enabled, the keypad name is
presented in the lower line of the display.
Exit delay clearing enable
[Fin.exit delay] – if this option is enabled, the exit delay time in
partitions with the “Exit delay clearing” option enabled can be shortened after pressing in
turn the
keys.
Show viol. zones
[Zone violation] – if this option is enabled, violating the CHIME signal
triggering zone result additionally in the zone name being displayed, when the keypad is in
the wake-up mode.
Auto-Arm delay countdown
[Auto-arm delay] – if this option is enabled, the auto-arm delay
countdown in partition is indicated by beeps.
Show disarm messages
[Show disarming] – if this option is enabled, the keypad displays
the disarming message irrespective of how the system has been disarmed. If this option is
disabled, the keypad displays the disarming message only when the system has been
disarmed from this keypad.
Show arm messages
[Show arm] – if this option is enabled, the keypad displays the arming
message. If the option is disabled, the arming message is not displayed.