INT-AV 

AUDIO ALARM VERIFICATION MODULE 

int-av_en 08/13 

The INT-AV module enables audio alarm verification to reduce the number of false alarms. 
After having received alarm message from the control panel, the operator of telephone 
monitoring station is able to listen-in on the sounds coming from the premises to confirm 
whether there is an intrusion. Owing to the module, the operator can try to contact the people 
on the premises to determine if the alarm is real or false. The listen-in and talk features are 
also available to the alarm system users. They can call the control panel number and, after 
entering the telephone code, get access to these features at any time. 
Listen-in and communication with the people on the protected premises are possible due to 
the INT-AVT terminals. The terminal is equipped with a microphone and a speaker. The 
module delivery set includes one INT-AVT terminal. Up to four INT-AVT terminals can be 
connected to the module. 
The module works with the INTEGRA / INTEGRA Plus control panels (firmware version 1.12 
or newer). This manual applies to the module electronics version 1.4 and firmware version 
1.00 (or newer). 

Notes: 

 

Only one INT-AV module can be connected to the control panel. 

 

If an INT-VG module is connected to the control panel, the module firmware version must 
be 1.02 or newer. 

1.  INT-AV module features 

  Two-way (listen-in / talk) audio alarm verification. 

  Keeping telephone connection with the monitoring station open after the control panel has 

sent alarm message (line hold mode). 

  Receiving phone calls from the monitoring station after the control panel has sent alarm 

information (call back mode). 

  Availability of the listen-in / talk features to the users having a telephone code. 

  Support for up to four INT-AVT terminals. 

2.  Specifications 

Supply voltage ................................................................................................... 12 V DC ±15% 
Standby current consumption ..........................................................................................35 mA 
Maximum current consumption (INT-AV + 1xINT-AVT) .................................................160 mA 
Maximum current consumption (INT-AV + 4xINT-AVT) .................................................500 mA 
Environmental class according to EN50130-5 ......................................................................... II 
Operating temperature range..................................................................................-10...+55 °C 
Maximum humidity..........................................................................................................93±3% 
Dimensions 

INT-AV (electronics board) ............................................................ 57 x 80 mm 
INT-AVT (enclosure).............................................................35 x 127 x 22 mm 

Summary of Contents for INT-AV

Page 1: ...odule works with the INTEGRA INTEGRA Plus control panels firmware version 1 12 or newer This manual applies to the module electronics version 1 4 and firmware version 1 00 or newer Notes Only one INT...

Page 2: ...anel ON no communication with the control panel sockets for connecting the INT VG voice module CA 64 SM voice synthesizer expander or SM 2 synthesizer RS 232 port TTL standard for updating the module...

Page 3: ...should be installed indoors in spaces with normal air humidity 4 1 Installing the INT AV module 1 Secure the module in the control panel enclosure 2 Connect the CLK and DTA terminals to the correspond...

Page 4: ...The cover will still be connected to the base by the speaker wires When opening the INT AVT terminal enclosure be careful not to rip off the speaker attached to the base Any changes in the constructio...

Page 5: ...e also for presence of the INT AVT terminals connected to the module Disconnecting the module from communication bus changing the position of DIP switches swapping the module with another one in which...

Page 6: ...MF tone by the control panel If this option is disabled alarm verification by the monitoring operator station will only be possible after entering the code The option is available if the VERIF AFTER R...

Page 7: ...option is enabled the module can be operated by means of DTMF commands compliant with SATEL standard and if it is disabled by means of DTMF commands compliant with SIA standard All command are describ...

Page 8: ...l the telephone number of control panel Hang up after the number of rings programmed by the installer Call again within three minutes The call will be answered by the control panel immediately Establi...

Page 9: ...es session and returns to phone answering function if the INT VG module is connected to the control panel returns to the voice menu 88 8 Terminates session with call back for station operator 99 0 Ter...

Page 10: ...es session Cancels first digit of a 2 digit command 0 0 Activates the level 0 command set 1 1 Activates the level 1 command set 8 Updating module firmware When a new version of the module firmware com...

Page 11: ...SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 58 320 94 00 info satel pl www satel eu...

Reviews: