background image

 SATEL 

CA-6 

KLED 

  ON with a short extinguishment every 2 seconds – detector tamper 

(2EOL zone type), 

  flashing 2 every 2 seconds – tamper memory (detector was tampered 

with - 2EOL zone type), 

  blinking slowly – zone bypassed (indicated only with the partition 

disarmed). 

 

Some of the control panel states are additionally indicated by the following LED 
combinations: 

 

 [

POWER

] and 

 

[

PHONE

] LEDs are blinking alternately - the control panel is in 

the service mode; 

 

 [

POWER

], 

 

[

PHONE

] and 

 [

TROUBLE

] LEDs are blinking simultaneously - the 

control panel signals entering into the user functions menu; 

 

 [

POWER

], 

 

[

PHONE

], 

  [

TROUBLE

] and 

 [

ALARM

] (both) LEDs are ON - the 

control panel performs the alarm memory display function; 

 

  [

TROUBLE

] LED is blinking, 

 [

POWER

] and 

 

[

PHONE

] LEDs are ON - the 

control panel performs the trouble memory display function. 

For further information regarding the installation and operation of the keypad please 
refer to the I

NSTALLER MANUAL 

and U

SER MANUAL

 of the CA-6 alarm control panel. 

Technical data 

Nominal supply voltage (±15%).......................................................................... 12V DC 
Average current consumption.................................................................................15mA 
Operating temperature range ................................................................... -10°C…+55°C 
Housing dimensions (width x height x thickness).................................... 144x80x27mm 
 
 
 

The latest EC declaration of conformity and product approval certificates 

are available for downloading on the 

www.satel.pl

 website 

 

 
 
 
 
 

SATEL sp. z o.o. 

ul. Schuberta 79 

80-172 Gda

ń

sk 

POLAND 

tel. + 48 58 320 94 00 

[email protected] 

www.satel.pl 

Reviews: