SATEL APMD-150
3
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
1. Remove the front cover (Fig. 2).
2. Install the battery and add the detector to the wireless system (see the ACU-100 /
ACU-250 / ACU-120 / ACU-270 controller manual or the INTEGRA 128-WRL / VERSA /
VERSA Plus / VERSA IP control panel installer manual). The sticker with 7-digit serial
number which shall be entered when registering the detector in the system can be found
on the electronics board.
3. Replace the cover.
4. Fasten the detector temporarily at the place of its future installation.
5. Check the level of signal received from the detector by the ACU-100 / ACU-250 /
ACU-120 / ACU-270 controller or the INTEGRA 128-WRL control panel. If the signal level
is lower than 40%, select another place for installation. Sometimes, it is sufficient to shift
the device ten or twenty centimeters to obtain a considerable improvement in the signal
quality.
6. Remove the front cover (Fig. 2).
7. Remove the electronics board (Fig. 3).
8. Make the openings for screws in the back tamper unit.
9. Screw the back tamper unit to the wall (Fig. 4) or to the bracket fixed to the wall (Fig. 5).
10. Screw the enclosure base to the back tamper unit (Fig. 6).
11. Fasten the electronics board.