SATEL AOD-200 

  alarm – the red LED is ON for 2 seconds. 

Supervision of detector signal path 

In case of signal path failure, the detector sends information about alarm during each 
transmission (constant violation). 

Battery status control 

When the battery voltage is below 2.75 V, information about low battery is sent during each 
transmission. 

3.  Electronics module 

 TMP terminals – tamper input (NC). 
 pins to enable /disable the tamper input. If 

no additional tamper switch is connected 
to the TMP terminals, jumper should be 
placed across the pins. 

 CR123A lithium battery. 
 microwave sensor. 
 green LED. 
 red LED. 
 yellow LED. 

The LEDs are working for 2 minutes 
after battery is inserted, as well as in 
the test mode (see: “Test mode”). 

During detector startup, all LEDs are 
blinking alternately for about 40 
seconds. 

 dusk sensor. 
 dual element pyrosensor. 

Do not touch 

the pyroelectric sensor, so as not to 
soil it.

 

 tamper switch activated by cover removal. 

 fixing screw holes. 

On the other side of the electronic board is a tamper switch activated by removing the 
detector from the wall. 

When mounting the detector on the angle or ball bracket, it is recommended to install 
additional tamper switch. 

4.  Installation 

There is a danger of battery explosion when using a different battery than 
recommended by the manufacturer, or handling the battery improperly. 

Summary of Contents for AOD-200

Page 1: ...aod 200_en 04 17 WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD 200 Firmware version 1 0 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...is to continually upgrade the quality of its products which may result in some changes of their technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us http www satel eu Hereby SATEL sp z o o declares that this detector is in compliance with the essential requirements and other relevant provisions of Directive 1999 5...

Page 3: ...e Supervision of detector signal path Battery status control Tamper protection against cover removal and tearing enclosure from the wall Weatherproof enclosure featuring a very high mechanical strength 2 Description The detector occupies two positions in the ABAX system the first one motion detector the other one dusk detector Alarms The detector reports alarm in the following cases the infrared s...

Page 4: ...r indicates whether motion has been detected by the infrared sensor The passive mode prolongs the battery life The alarm information is sent instantly Test mode If you want to test the detector you can remotely start the test mode When in the test mode the detector LEDs are working Time delay for the dusk sensor in test mode is 3 seconds LEDs The LEDs are working for 2 minutes after inserting the ...

Page 5: ...icrowave sensor green LED red LED yellow LED The LEDs are working for 2 minutes after battery is inserted as well as in the test mode see Test mode During detector startup all LEDs are blinking alternately for about 40 seconds dusk sensor dual element pyrosensor Do not touch the pyroelectric sensor so as not to soil it tamper switch activated by cover removal fixing screw holes On the other side o...

Page 6: ... the recommended height Fig 3 I If traffic nearby or objects moving out of the protected area cause an alarm move the detector slightly downwards or reduce the detector sensitivity Fig 3 II Install the detector so that the expected movement of an intruder will be across the coverage pattern Fig 3 III Don t install the detector closer than 3 meters from the moving objects eg tree branches bushes la...

Page 7: ...n angle bracket or ball bracket make a hole in the enclosure base for the additional tamper switch cables 10 Mount the enclosure base to the wall to the angle bracket see Angle bracket mounting or to the ball bracket see Ball bracket mounting Use screw anchors suitable for the mounting surface concrete wall drywall etc The screw anchors should guarantee required mechanical strength In Figure 6 pos...

Page 8: ...itch holder on the other side 2 Prepare openings in the bracket for screws 3 Using wall plugs screw anchors and screws fasten the bracket to the wall 4 Run the tamper switch wires through the hole made in the enclosure base and connect them to the TMP terminals 5 Using screws fasten the enclosure base to the bracket Fig 9 Ball bracket mounting 1 Attach extra tamper switch screw the holder to the t...

Page 9: ...anchors and screws fasten the ball bracket to the wall Fig 8 IV 4 Run the tamper switch wires through the hole made in the enclosure base and connect them to the TMP terminals 5 Using screws fasten the enclosure base to the ball bracket Fig 10 ...

Page 10: ... to 500 m Battery CR123A 3 V Battery life expectancy up to 2 years Standby current consumption 70 µA Maximum current consumption 30 mA Microwave frequency 24 125 GHz Detectable speed 0 3 3 m s Warm up period 40 s Recommended installation height 2 4 m Security grade Grade 2 Standards complied with EN50131 1 EN50130 4 EN50130 5 IP code IP54 Environmental class according to EN50130 5 IIIa Operating t...