Satel abax 2 ADD-200 Manual Download Page 7

SATEL 

ADD-200 

There  is  a  danger  of  battery  explosion  when  using  a  different  battery  than 
recommended by the manufacturer, or handling the battery improperly. 

Be  particularly  careful  during  installation  and  replacement  of  the  battery. 
The manufacturer  is not  liable  for  the  consequences  of incorrect  installation  of 
the battery. 

The  used  batteries  must  not  be  discarded,  but  should  be  disposed  of  in 
accordance with the existing rules for environment protection. 

The figures below only show the detector installed vertically, but the detector may be installed 
in any position (position of the detector has no effect on the operation of the sensors). 

1.  Install  the  battery  and  add  the  detector  to  the  wireless  system  (see  ABAX 2  controller 

manual). The sticker with the serial number required for registration of the detector in the 
system can be found on the electronics board. 

If  the  ABAX 2  controller  is  connected  to  the  VERSA  series  control  panel,  add  and 
configure the ADD-200 detector using the DLOADX program. 

2.  Press  the  gasket  (included  with  the  detector)  into  the  groove  of  the  enclosure  cover. 

The gasket  must  fill  the  entire  groove,  so  that  both of the  gasket  ends touch  each other 
(Fig. 3). Do not shorten the gasket 

– it is fitted to the length of the groove. 

It  is  recommended  that  the  ends  of  the  gasket  are  situated  on  the  bottom  of  the 
enclosure after the cover is replaced. 

3.  Replace the cover and fasten it to the enclosure base with 4 screws (Fig. 4). 

 

4.  Place the detector at the location of its future installation. 

5.  Check the level of signal received from the detector by the ABAX 2 controller. If the signal 

level is lower than 40%, select another place for installation. Sometimes, it is sufficient to 
shift the device ten or twenty centimeters. 

The ARF-200 tester allows you to test the level of radio signal at the location of future 
installation without having to place the detector on-site. 

6.  Use screws to secure the enclosure base to the mounting surface. Select appropriate wall 

plugs  based  on  the  type  of  the  mounting  surface  (different  for  concrete  or  brick  wall, 
different for plaster wall, etc.). 

Summary of Contents for abax 2 ADD-200

Page 1: ...ADD 200 Wireless outdoor dusk and temperature detector Firmware version 1 00 add 200_en 09 20 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at https support satel eu Hereby SATEL sp z o o declares that the radio equipment type ADD 200 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is...

Page 3: ... 1 Features 2 2 Description 2 Radio communication 2 Dusk sensor 2 Temperature sensor 3 Energy saving mode ECO 4 Test mode 4 LED 4 Battery status control 4 Electronics board 4 3 Installation 4 4 Specifications 6 ...

Page 4: ...mote configuration LED indicator ECO option for longer battery life Battery status control Weatherproof enclosure of high mechanical strength 2 Description Radio communication The detector connects to the controller at regular time intervals to provide information about its state periodical communication Additional communication will take place when light intensity drops below the threshold rises ...

Page 5: ... lx 125 lx 15 150 lx 188 lx 16 200 lx 250 lx Table 1 Temperature sensor You can program one of two temperature detection thresholds low L or high H The detector will alert of the threshold being exceeded if the temperature drops below the programmed value in the case of the low L threshold rises above the programmed value in the case of the high H threshold Information about the current temperatur...

Page 6: ...ng the battery to indicate the warm up of the detector When in test mode the LED indicates periodical communication short flash 80 milliseconds Battery status control When the battery voltage is below 2 75 V information about low battery is sent during each transmission Electronics board Do not remove the electronics board from the enclosure to avoid damage to the components on the board Figure 2 ...

Page 7: ...nd configure the ADD 200 detector using the DLOADX program 2 Press the gasket included with the detector into the groove of the enclosure cover The gasket must fill the entire groove so that both of the gasket ends touch each other Fig 3 Do not shorten the gasket it is fitted to the length of the groove It is recommended that the ends of the gasket are situated on the bottom of the enclosure after...

Page 8: ... piece of fabric 10 End the test mode 4 Specifications Operating frequency band 868 0 MHz 868 6 MHz Radio communication range in open area ACU 220 up to 2000 m ACU 280 up to 1600 m Battery CR123A 3 V Battery life expectancy up to 2 years Light intensity measurement range 2 lx 250 lx Temperature measurement range 30 C 70 C Temperature measurement accuracy 1 C Standby current consumption 20 µA Maxim...

Reviews: