INSTALLATION AND SERVICE INSTRUCTIONS
Models: 65-064, 65-065, 65-066, 65-067, 65-068
LED Wall Light
PRECAUTION
Before beginning installation or service, disconnect the power by turning off the circuit breaker. Turning the power off by using the light switch is not
sufficient to prevent electrical shock. This floodlight is for outdoor use and should not be used in areas of limited ventilation or high ambient temperature.
All work should be performed by a qualified electrician.
Important: This product must be installed in accordance with the applicable installation code by a person familiar with the construction
and operation of the product and the hazards involved.
INSTALLATION:
Direct wall mounting to recessed box:
1. Remove the rear mounting plate by loosening the two allen head set screws from bottom of the plate.
Direct mounting to junction box:
2. Fasten the mounting plate to a recessed outlet or other mounting surface. Use the integrated bubble leveler to ensure that the plate is level.
3. Splice the power leads from the back of the fixture to the branch circuit leads from the junction box. Attach black to black (hot),
white to white (neutral), and green to green (ground). Push the splices into the junction box.
4. Align the fixture against the mounting plate and retighten the set screws to secure the fixture in place.
5. For wet locations, caulk between the rear housing and the mounting surface to prevent water from entering the fixture from behind.
Wall-mounted wiring box with conduit feed:
2. Attach the wiring box to the desired location using the bolt holes provided.
3. Remove the threaded plug(s) and route electrical conduit to the holes desired. Feed the branch circuit wires
through the conduit into the wiring box.
4. Splice the fixture power leads to the power leads inside the wiring compartment box – black to black (hot), white to white (neutral), and green to
green (ground).
5. Align the fixture against the wiring box and tighten the set screws to secure the fixture in place. Take care to not pinch the power wires.
Pole mount using slip fitter, knuckle, or trunnion:
2. Splice the fixture power leads to the power leads inside the wiring compartment box – black to black (hot), white to white (neutral),
and green to green (ground).
3. Align the wiring box against the back of the fixture and tighten the set screws to secure it in place.
Slip fitter:
4. Splice the fixture power leads to the branch circuit power
5. Slide the slip fitter onto the end of the pole, rotate to the desired position, and tighten the set screws.
6. Unscrew the philips head screws in the side of the slip fitter and remove the hinge plate.
7. Loosen the hex bolt inside the hinge, adjust the fixture to the desire angle, and retighten. Replace the cover.
Trunnion:
4. Mount the trunnion in place using the bolt holes provided.
5. Route the fixture waterproof cable to interior of the pole using a waterproof connector. Splice the fixture power leads
to the branch circuit leads – black to black (hot ),white to white(neutral),and green to green (ground).
6. Remove the adjustment screw in trunnion hinge and adjust to the desired angle .Replace the screw.
Knuckle:
4. Splice the knuckle power leads to the branch circuit power leads and push the splices inside the threaded hole.
5. Screw the knuckle into the threaded hole, rotate to the desired angle, then tighten the mounting nut.
6. Loosen the allen head screw in the side of the knuckle hinge and adjust to desired angle. Then retighten.
NOTE:
The LED module is preinstalled and prepositioned. DO NOT OPEN the unit.
DO NOT TOUCH THE SURFACE OF THE LEDS. This fixture must be mounted in the LENS DOWN position.
NOTE: LED units are multi-volt 120V-277V. No additional tap wires are necessary.
TROUBLE SHOOTING CHECKLIST: If the light does not work.
1. Check your power source.
2. Check electrical connections.