4. DISASSEMBLY AND ASSEMBLY
4.1. GENERAL.
When disassembling the meter register, be
extremely careful not to lose or intermix any of
the washers round on the shafts. By doing so,
potential problems with end-play and backlash
adjustments will be greatly lessened. When
removing retaining rings or other parts from
shafts, do not hold the shaft with any tool that
might gouge or create burrs on the shaft.
4.2. REMOVAL OF MAJOR GROUPS.
Instructions for removal of aIl shaft groups are
provided.
1. If present, remove the retaining ring
securing the reset idler gear to the reset idler
gear shaft.
2. Remove retaining rings and washers
securing the pinion, reset, anti-topping and
clutch shafts to the right-hand side plate
(Figure 7). Remove screws and lockwasher
securing the totalizer group and rear mounting
bar tram right-hand side plate.
3. Remove side plate.
CAUTION: DO NOT LOSE OR INTERMIX
WASHERS FROM EACH SHAFT.
Note: Remove only those shaft groups
necessary to gain access to parts being
replaced.
Figure 5. Right -Hand Side Plate.
Figure 6. Left -Hand Side Plate.