115
EN
Operating instructions SATAminijet 1000 K/H RP/HVLP
Operating instructions SATAminijet 1000 K/H RP/HVLP
7.1. Adjustment of spray gun inlet pressure
Notice!
•
Fully pull trigger and adjust spray gun inlet pressure (see chapter 2)
according to one of the follwing sections
[3-1], [3-2], [3-3]
to
[3-4]
,
then release trigger.
•
With
[3-2], [3-3]
and
[3-4]
, the air micrometer
[1-8]
must be fully
opened/in vertical position.
•
If the required spray gun inlet pressure is not reached, the pressure
at the compressed air circuit has to be increased; too high pressure
results in too high trigger forces.
[3-1] SATA adam 2
(accessory / accurate method).
[3-2] Separate gauge with control device
(accessory).
[3-3] Separate gauge without control device
(accessory).
[3-4]
Pressure regulation at the
compressed air circuit
(most inaccu-
rate method):
Rule of thumb:
Pressure at the pressure reducer must be set
0.6 bar higher than the recommended spray gun inlet pressure per
every 10 m of air hose (inner width 6 mm).
7.2. Adjustment of material flow
[4-1], [4-2], [4-3] and [4-
4] - material flow control fully opened
Notice!
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
With SATAminijet 1000 K RP/HVLP:
Fully pull trigger and adjust re-
quired material supply pressure, e.g. at pressure tank.
7.3. Adjustment of spray pattern
• Adjustment of the flat fan (factory setting)
[5-1]
.
•
Adjustment of the round fan
[5-2]
.