Step
Display
Selectable
values
Description
3
AL
From
5
to
20 (5)
Minimum option of setting the heating temperature in
degrees °C. With this option, you can limit the heating
temperature that can be set using the thermostat.
4
FH
From 20 to 70
(40)
Maximum set temperature of floor heating in °C. You
can limit the maximum set floor heating temperature.
5
FL
From 5 to 20 (5)
Lowest set temperature of floor heating in °C. You can
limit the minimum set floor heating temperature.
6
SEN
AL / In / OU (In)
Thermostat mode
–
Use of internal or external sensors.
AL
–
The thermostat uses both sensors for temperature
read
–
internal and external underfloor.
In
–
Thermostat uses internal temperature sensor only.
OU –
Thermostat uses external underfloor temperature
sensor only.
7
bL
2 / 3 (2)
Use this option to change the screen brightness.
2
–
Screen backlight lasts
3
0 seconds;
3 –
Screen backlight is always turned on
8
P51
0
/ 7 (0)
Heating Schedule programs.
Here you can turn on/off and set on how the heating
program schedule will work.
0
–
The heating program schedule is turned off;
7 – 7
days
(each day separately; table 1)