Electronic Analytical and Precision Balances 

 

Installation and Operating Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for Master series

Page 1: ...Sartorius Basic Series Electronic Analytical and Precision Balances Installation and Operating Instructions...

Page 2: ...2 B 120S...

Page 3: ...3 B 310P B 310S...

Page 4: ...4 B 410 B 610 B 3100P B 3100S B 4100 B 6100...

Page 5: ...cylinder only B 310P and B 310S 7 Pan adapter only B 310P and B 310S 8 Power receptacle 9 Level indicator only B 120S B 310P B 310S B 3100P and B 3100S 10 Leveling foot only B 120S B 310P B 310S B 310...

Page 6: ...ipment delivered Electronic Analytical or Precision Balance of the Basic Series is manufactured and tested in compliance with the following DIN VDE regulations DIN IEC 348 VDE0411 Safety requirements...

Page 7: ...ns 9 How to Start Up the B 120 S 10 How to Start Up the B 310P and B 310S 11 How to Start Up the B 410 B 610 12 B 3100P B 3100S B 4100 and B 6100 Operation 13 Calibration 15 Balance Operating Program...

Page 8: ...ance AC adapter Dust cover Pan adapter Base plate of the round draft shield Weighing pan Glass draft shield cylinder Round draft shield lid Balance AC adapter Dust cover Weighing pan Do not miss out o...

Page 9: ...apt it to your particular requirements and to the specific ambient condi tions simply by changing the menu code settings in the balance operating program For this purpose please read pages 16 to 18 Af...

Page 10: ...ting printed on this unit is identical to your local line voltage rating Plug the cord of the AC adapter into the power receptacle Se cure the connection by tightening the knurled collar Now plug the...

Page 11: ...s powered by an AC adapter Make sure that the voltage rating printed on this unit is identical to your local line voltage rating Plug the cord of the AG adapter into the power receptacle of the balanc...

Page 12: ...n this unit is identical to your local line voltage rating Plug the cord of the AC adapter into the power receptacle of the balance For models B 410 and B 610 secure the connection by tightening the k...

Page 13: ...y to operate without warmup POWER OFF The balance was disconnected from line power reconnection to line power after the balance was unplugged power failure or outage CAL The calibration function has b...

Page 14: ...power is turned on an automatic self test of all essen tial electronic functions is performed This self test ends with one of the following readouts 0 0000 g 0 000 g 0 00 g 0 0 g one of these readouts...

Page 15: ...econds until the calibration weight readout appears in the display Center the calibration weight on the weighing pan Now the weight unit symbol is displayed An acoustic Signal in dicates the end of th...

Page 16: ...urned off STANDBY state hold down the tare control 13 while you press the ON OFF key 15 Upon completion of the automatic self test release the tare control as soon as CH5 is displayed The Status of th...

Page 17: ...e The o symbol that appears indicates the actual setting To change any menu code settings C mode press the tare control as soon as the appropriate code is displayed Brief display of BUSY and the o sym...

Page 18: ...rmat c 5 2 2 Singapore taels tl C 1 3 1 Last decimal ON c 5 2 3 Taiwan taels tl C 1 3 2 Last decimal OFF c 5 2 4 Grains gr C 1 3 3 Last decimal at stability c 5 2 5 Pennyweights dwt C 1 3 4 All decima...

Page 19: ...g cham ber is not completely closed for B 120S The sample or object does not have a stable weight Set up scale in another area Access the menu to adapt scale to the particular type of weigh ing enviro...

Page 20: ...x lines sec 1 5 Printer housing W x D x H in mm 150 x 138 x 43 in inches5 9 x 5 4 x 1 7 Data printer with set of programs 73802 to order replace with one of the codes below 201 for animal weighing 207...

Page 21: ...tery pack YRB 01Z approx 12 hours of Operation rechargeable via AC adapter only for B 3100S P B 4100 B 6100 Carrying case forB120S YDB 01A for B 310 P S YDB 01L for B 410 B 610 YDB 02L B 3100 P S B 41...

Page 22: ...283 303 10 o C 30 o C 273 313 0 o C 40 o C Allowable relative humidity 25 85 15 85 moisture proof rating Sensitivity drift within 10 30 o C o C 2 10 6 5 10 6 2 10 6 Pan size mm in 90 3 5 130 5 1 130 5...

Page 23: ...bility range d 0 25 64 selectable Ambient temperature range K 273 313 0 o C 40 o C Allowable relative humidity 15 85 moisture proof rating Sensitivity drift within 10 30 o C o C 5 10 6 Pan size mm in...

Page 24: ...ty range d 0 25 64 selectable Ambient temperature range K 273 313 0 o C 40 o C Allowable relative humidity 15 85 moisture proof rating Sensitivity drift within 10 30 o C o C 2 10 6 5 10 6 5 10 6 Pan s...

Page 25: ......

Page 26: ...Copyright by Sartorius AG G ttingen Deutschland All rights reserved No part of this publication may be printed or translated in any form or by any means without the prior written permission of Sartori...