background image

Overview

Specifications

Model

GD502

ELT103

ELT602

ELT402

ELT202

Weighing capacity

500 ct

100 g

600 g

400 g

200 g

Readability

g

0.005

0.001

0.01

0.01

0.01

Tare range (subtractive)

g

500 ct

100 g

600 g

400 g

200 g

Linearity

<

±g

0.015 ct

0.003 g

0.03 g

0.03 g

0.035 g

Operating temperature range

10°C to 30°C (273°K to 303°K; 50°F to 86°F)

Stabilization time (average)

s

2.5

2.5

2

2

2

Adaptation to ambient conditions

By selection of 1 of 4 optimized filter levels; display update:
0.1– 0.8 (depends on filter level selected)

Calibration weight

g

100 (F1)* 100 (F1)* 200 (F2)* 200 (F2)* 100 (F2)*

Net weight, approx. 

kg

1.2

1.2

1.35

1.35

1.25

Pan size

mm

107 

d

107 

d

140

+

127 140

+

127 140

+

127

Power source/voltage/frequency

AC adapter, 230 V or 115 V, +15% to –20%, 48–60 Hz

Power consumption (average)

W

1

1

0.8

0.8

0.8

Power requirements, DC voltage

12 V to 20 V

Hours of operation with battery:
– Mignon, AA alkaline manganese

(2200 mAh), avg.

h

35

35

35

– Rechargeable 1500 mAh, 

fully ch., (NiMH), avg.

h

24

24

24

Model

ELT6001 ELT4001 ELT2001 ELT1001 ELT601

ELT6000

Weighing capacity

g

6000

4000

2000

1000

600

6000

Readability

g

0.1

0.1

0.1

0.1

0.1

1

Tare range (subtractive)

g

6000

4000

2000

1000

600

6000

Linearity

<

±g

0.2

0.2

0.2

0.2

0.2

2

Operating temperature range

10°C to 30°C (273°K to 303°K; 50°F to 86°F)

Stabilization time (average)

s

2

2

2

1.5

1.5

1.5

Adaptation to ambient conditions

By selection of 1 of 4 optimized filter levels; display update: 
0.1– 0.8 (depends on filter level selected)

Calibration weight

kg

5 (F2)

2 (F2)

2 (F2)

0,2 (F2)*

0,1 (F2)*

5 (M1)

Net weight, approx. 

kg

1.25

1.25

1.25

1.1

1.1

1.1

Pan size

mm

140

+

127

Power source/voltage/frequency

AC adapter, 230 V or 115 V, +15% to –20%, 48–60 Hz

Power requirements, DC voltage

12 V to 20 V

Power consumption (average)

W

0.8

0.8

0.8

0.6

0.6

0.6

Hours of operation with battery:
– Mignon, AA alkaline manganese

(2200 mAh), avg.

h

35

35

35

60

60

60

– Rechargeable 1500 mAh, 

fully ch., (NiMH), avg.

h

24

24

24

42

42

42

* = included in delivery

17

Summary of Contents for Element Series

Page 1: ...Operating Instructions Sartorius Element Series Electronic Precision Balances Electronic Gem Scale 98648 013 44 ...

Page 2: ...wer supply is identical to your local line voltage Use only commercially available non rechargeable or rechargeable battery 8 AA Mignon not included The rechargeable batteries are not charged when you use the AC adapter Please use the charger to recharge the batteries outside the balance scale The balance scale is energized at all times unless you disconnect the AC adapter and if connected the bat...

Page 3: ...103 GD502 Calibration weight Round glass draft shield Only with GD502 Gem tray Installation Choose a location that is not subject to the following negative influences Heat heater or direct sunlight Drafts from open windows and doors Extreme vibrations during weighing Excessive moisture Setting Up the Balance Scale Place the components on the balance scale in the following order Weighing pan Round ...

Page 4: ... adapter into an electrical outlet LISTED power supply 11 V 21 V compliant with NEC Class 2 output Below Balance Scale Weighing A port for a below balance scale weighing hanger is located on the bottom of the balance scale Open the cover plate on the bottom of the balance scale Attach the sample e g using a suspension wire to the hanger Install a shield for protection against drafts if necessary ...

Page 5: ...e scale using a sepa rate charger Lay the balance scale on its side Lift the compartment cover Insert the non rechargeable 8 AA Mignon or rechargeable batteries into the compartment Make sure to connect the positive and negative poles correctly Close the battery compartment press down on the cover until it clicks into place All used batteries are classified as waste that requires special handling ...

Page 6: ...n the diagram until the air bubble is centered within the circle of the level indicator In most cases this will require several adjustment steps Removing Weights for Calibration Span Adjustment only for models ELT103 ELT602 ELT402 ELT202 ELT1001 ELT601 GD502 Grasp the tab to turn and pull out the weight compartment Follow instructions on page 14 for calibration span adjustment 6 ...

Page 7: ...ss the e key If necessary zero the balance scale press the w key If necessary change the configuration settings see the chapter entitled Configuration If desired load the factory settings see the chapter entitled Configuration menu item 9 1 Additional functions Switching off the balance scale press the e key Battery operation automatic shut off after 2 5 or 10 minutes see chapter on configuration ...

Page 8: ...weight unit v Menu code Unit Conversion factor Display 1 user1 Grams 1 00000000000 o 2 grams fact setting ELT models Grams 1 00000000000 g 4 carat fact setting GD502 Carats 5 00000000000 o 5 Pound2 Pounds 0 00220462260 lb 6 ounce2 Ounces 0 03527396200 oz 7 tryo2 Troy ounces 0 03215074700 ozt 8 tl hon2 Hong Kong taels 0 02671725000 tlk 9 tl sin2 Singapore taels 0 02645544638 tl 10 tl ta2 Taiwanese ...

Page 9: ... scale 5 Zero the balance scale w 6 Place reference sample quantity 20 on the balance scale 7 Select reference sample quantity in increments of 1 1 2 3 99 or v repeatedly briefly or in increments of 10 10 20 30 100 v 2 sec 8 Confirm selected reference sample quantity 9 Place uncounted parts on balance scale 10 Toggle display between mean piece weight total weight and quantity v repeatedly 11 Unloa...

Page 10: ...ace empty container on the balance scale 5 Zero the balance scale w 6 Place the reference weight for 100 on the balance scale 7 If desired change the number of decimal places displayed 100 0 100 00 or 100 factory setting v repeatedly 8 Confirm selected no of decimal places 9 Place unknown weight on the balance scale 10 Toggle display between weight and percentage v repeatedly 11 Unload the balance...

Page 11: ...splay application is active 4 If necessary zero the balance scale w 5 Place sample on balance scale 6 Start application program v Symbol flashes on the display the weight value is locked 7 Unload the balance scale the weight value remains displayed for a further 5 seconds or 8 Zero the balance scale w 9 End the Display Hold application 2 sec 10 Reactivate Display Hold if no other v application pro...

Page 12: ...ed steadily symbol flashes 7 Remove sample from balance scale 8 Place the next sample on the balance scale in this example 575 g 9 Store value in memory Totalized stored weight is displayed symbol flashes Note symbol remains on indicating stored value in memory until cleared 10 To view the current weight for 2 seconds v if a printer is connected a printout is generated 11 Clear totalizing memory v...

Page 13: ...lance scale w 5 Start application program v 6 Confirm the display airval 7 Determine weight of the sample in air place sample on the balance scale 8 Store weight in air value 9 Remove sample from balance scale 10 Determine weight of sample in liquid connect wire and set up beaker 11 Confirm the display Water 12 Place sample in liquid 13 Store the weight in liquid value and view the result 14 Clear...

Page 14: ...f the balance scale here model ELT 6001 Step Key or instruction Display 1 Switch on the balance scale e 2 Zero the balance scale w 3 Start calibration q The preset calibration weight is displayed without the weight unit in this example 5000 g 4 To select a different calibration weight value v repeatedly 5 Confirm calibration weight value and start calibration span adjustment After the zero point i...

Page 15: ...nditions 1 2 Application filter 1 2 1 ο Final readout 1 2 2 Filling 1 3 Stability range 1 3 1 1 4 digit 1 3 2 1 2 digit 1 3 3 1 digit 1 3 4 ο 2 digits 1 3 5 4 digits 1 5 Calib adjust linearization 1 5 1 ο Calibration span adjustment Function of the Q key 1 5 2 Linearization for service personnel only 1 5 3 Key blocked 1 6 Auto zero 1 6 1 ο On 1 6 2 Off 1 7 1st weight unit or 2nd unit 1 7 1 User de...

Page 16: ... scale not zeroed Press w to tare the balance scale Balance scale is loaded Unload the balance scale appErr Weight is too light or there is Increase the weight no sample on the balance scale on the balance scale with application in use PrtErr Data interface for Contact the Sartorius printing is blocked customer service center Bal Err Balance scale loaded or defective Unload balance scale before wh...

Page 17: ...Mignon AA alkaline manganese 2200 mAh avg h 35 35 35 Rechargeable 1500 mAh fully ch NiMH avg h 24 24 24 Model ELT6001 ELT4001 ELT2001 ELT1001 ELT601 ELT6000 Weighing capacity g 6000 4000 2000 1000 600 6000 Readability g 0 1 0 1 0 1 0 1 0 1 1 Tare range subtractive g 6000 4000 2000 1000 600 6000 Linearity g 0 2 0 2 0 2 0 2 0 2 2 Operating temperature range 10 C to 30 C 273 K to 303 K 50 F to 86 F S...

Page 18: ...tment rear side 100 g F1 Available on request Round glass draft shield Available on request 25 mm high Weighing pan Round Available on request Rectangular Available on request Pan support Round Available on request Rectangular Available on request Leveling feet set of one adjustable foot and one fixed foot Available on request Plug for level indicator port Available on request Covers Battery compa...

Page 19: ...19 C ...

Page 20: ...or translated in any form or by any means without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the right to make changes to the technology features specifications and design of the equipment without notice Status August 2005 Sartorius AG Goettingen Germany W4A000...

Reviews: