SE LP10 7000 Series Multi Point Lock
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 12VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
20
18
16
14
14
12
12
10
150
18
16
14
12
12
12
10
—
200
16
14
12
12
10
10
—
—
250
16
14
12
10
10
10
—
—
300
16
12
12
10
10
—
—
—
400
14
12
10
—
—
—
—
—
500
14
10
10
—
—
—
—
—
750
12
10
—
—
—
—
—
—
1,000
10
—
—
—
—
—
—
—
1,500
10
—
—
—
—
—
—
—
Wire Gauge Charts
Total
One-Way
Length of
Wire Run (ft)
Load Current @ 24VDC
1/4A
1/2A
3/4A
1A
1-1/4A
1-1/2A
2A
3A
100
24
20
18
18
16
16
14
12
150
22
18
16
16
14
14
12
10
200
20
18
16
14
14
12
12
10
250
18
16
14
14
12
12
12
10
300
18
16
14
12
12
12
10
—
400
18
14
12
12
10
10
—
—
500
16
14
12
10
10
—
—
—
750
14
12
10
10
—
—
—
—
1,000
14
10
10
—
—
—
—
—
1,500
12
10
—
—
—
—
—
—
5
Strip 1/4”
Overlap wires as shown. Use heat gun to set wires.
Wiring Diagrams
*Diagrams on following pages
Default Operation Mode:
• Red LED ‘ON’ when powered.
• Presenting a 13.56 MHz or 125 kHz credential causes LED to briefly
turn green and then return to red state.
• Presenting a FIPS 201 PIV credential causes LED to turn amber as
credential is authenticated. Reader emits a short beep when
credential is successfully read. Reference *Diagram #1.
Optional Operation Mode:
Connect selected TAMPER wire from reader to ElectroLynx cable pin 8.
Note: For fire rated doors solder sleeve (P/N 52-1373) to be applied to
desired lead 2.5” from base of reader. See diagram for application.
Connect Yellow TAMPER wire from ElectroLynx cable to desired EAC panel
control line.
As appropriate, use configuration card to activate desired mode on reader.
PIN8 (Yellow – TAMPER)
PIN 6 (Blue – RX COM)
PIN 4 (Green – Data 0)
PIN 2 (Red – Reader POS)
PIN 1 (Black – Reader NEG)
PIN 3 (White – Data 1)
PIN 5 (Orange – RX NO)
PIN 7 (Brown - EGND)
PIN 4 (Tan – DPS COM)
PIN 2 (Gray – Lock POS)
PIN 1 (Violet – Lock NEG)
PIN 3 (Pink – DPS NC)
Note: When Yellow TAMPER wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader performance will be impacted.
8 PIN CONNECTOR
4 PIN CONNECTOR
1-Black
2-Red
3-White
4-Green
5-Orange
6-Blue
7-Brown
8-Yellow
1-Violet
2-Gray
3-Pink
4-Tan
12VDC
(Reader)
WIEGAND
WIEGAND
RX
RX
EGND
TAMPER
12/24 VDC
(LOCK RELAY)
DPS
(NC)
DPS
(COM)
NEG
POS
DATA_1
DATA_0
NO
COM
EGND
OPEN
COLLECTOR
NEG
POS
DPS
DPS
The SE LP10 reader can be configured for various modes of LED and beeper operation. HID programming
cards are supported to configure the behavior for LED and beeper activity. Call 1-800-810-WIRE (9473) for
details. Along with the programming cards, the TAMPER wire can be connected within the panel and the
lock in order to enable some of the listed features.
Wire Gauge Charts