SE LP10 7000 Series Multi Point Lock
7 Fire Plate Installation and Earth Ground Connection
1. Remove lower left screw from mounting plate. Feed screw through green/yellow ground wire ring terminal.
Reinstall screw. Ensure that green/yellow wire points toward top of door in order to avoid interference
with escutcheon.
2. Fasten plate with two #8 x 1 1/4” Phillips pan head self-drilling screws.
Note: For non-fire rated doors, omit fire plate.
8A Position Inside Escutcheon & Wires (Non-ELR)
1. Carefully and neatly fold lock body wires onto themselves. ElectroLynx
connectors should be positioned side-by-side under the fire block plate.
Device connectors should be positioned side-by-side on top of the
ElectroLynx connectors.
2. Position inside escutcheon in order to ensure wires are not pinched.
Adjust wires as necessary to ensure they are clear of rear escutcheon.
Seat inside escutcheon against door.
Note: Be sure to cover, but not pinch wires when mounting escutcheon.
3. Insert two (2) #8-32 x 5/8” Phillips flat head escutcheon screws and thread
into mounting plate.
Inside of
Door
Fig. 7B
Fig. 7A
Fig. 8A
(Non-ELR)
(2) #8-32 x 5/8” Phillips
Flat Head Under-cut
Machine Screws
Inside of
Door